Piping and ancillary equipment(pumps): 191(g)(2)(C&D)/192(k)(2)(C&D) <br /> Visual Inspection: 191(g)(8)1192(k)(9) <br /> Piping Material of Construction: <br /> Tank parameters at time of inspection(empty,etc.): <br /> Pipe:1"Type L copper tube with soldered connections 14"depth,130 gallons <br /> Hose:Synthetic rubber <br /> Hose Fittings:Stainless steel Acute visual evidence of leaks:None <br /> Pump location(s): Condition of interior surface: <br /> Bolted to a steel mounting plate which is bolted to a steel service Good condition.No damage or evidence of corrosion. <br /> bay support beam. <br /> Condition of exterior surface: <br /> Pump type/capacity: <br /> Good condition.Paint is intact.No damage or evidence of <br /> Type:Graco Husky 1040 air operated diaphragm pump,1"NPT corrosion. <br /> polypropylene body Condition of nozzles,flanges,fittings at tank: <br /> Capacity:42 gallons per minute <br /> Good condition.No evidence of damage,cracks,or leaks. <br /> Material Storage: <br /> Condition of piping: <br /> Materials and characteristics:191(g)(7)/192(k)(8) Good condition.No evidence of damage or leakage.Properly <br /> Stored liquids in the waste oil storage tank are a mixture of various supported per the 2012 Uniform Plumbing Code. <br /> viscosity used motor oils and hydraulic oil.All of these are classified <br /> as type 1116 flammable and combustible liquids per Table B.1 of isual Inspection findings: A visual inspection of the tank and its affiliated <br /> NFPA Code 30A. umps,piping and ancillary equipment did not reveal signs of leaks,corrosion, <br /> weld cracks or breaks,or scrapes in protective coating which may cause a <br /> These liquids have the following HMIS Hazard Ratings: release from the tank system. A description of all discrepancies noted during the <br /> visual inspection is included with this report. Initials: 9<6 <br /> Health:1 (slight) <br /> Flammability:1 (slight) Seismic/Anchoring: <br /> Reactivity:0(minimal) <br /> Civil engineer wet stamped seismic/dynamic/hydrostatic load calculations <br /> Used motor oil and hydraulic is compatible with the steel tank liner provided as Attachment"C" <br /> and does not pose any potential for corrosive damage to the tank or <br /> ancillary equipment. reismically <br /> smic/Anchoring findings: The tank as designed and operated,and the <br /> tainment area in which it is located are adequately anchored and are <br /> sound. InitialsK <br /> Specific Gravity:0.91 <br /> Operating Capacity:500 gallons <br /> hemical compatibility findings:The materials identified above are compatible <br /> or contact with or proximity to the equipment,tank or tank system in thi <br /> assessment. Initials: K i <br />