Laserfiche WebLink
SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 600 East Main Street, Stockton, California 95202-3029 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sigov.org/ehd/unitiii.html <br /> CONTINUATION FORM Page: 6 of 6 <br /> OFFICIAL INSPECTION REPORT Date: 06/27/11 <br /> Facility Address: 20451 McHenry Ave Program: APSA <br /> SUMMARY OF VIOLATIONS <br /> CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> 33. The SPCC Plan site security section is incomplete. The Plan must include descriptions of how you <br /> secure and control access to the oil handling, processing & storage areas, secure master flow& drain <br /> valves, prevent unauthorized access to starter controls on oil pumps, secure out-of-service and loading/ <br /> unloading connections of oil pipelines, and address the appropriateness of security lighting to both <br /> prevent acts of vandalism and assist in the discovery of oil discharges. Immediately update the Plan to <br /> include all of the required security information. <br /> 41. Failed to use valves of manual, open and closed design, for the drainage of diked areas. The diesel <br /> tank secondary containment uses a electric float switch to remove liquid in the secondary containment. <br /> Immediately convert the valve to manual operation by removing the float or by some other means. <br /> 48. Integrity testing has not been conducted on the above ground petroleum storage containers and <br /> tanks at the facility. The SPCC plan does not include a discussion of Title 40 CFR §112.8(c)(6). <br /> The facility shall test or inspect each aboveground container for integrity on a regular schedule and <br /> whenever you make material repairs. Examples of these integrity tests include, but are not limited to: <br /> visual inspection, hydrostatic testing, radiographic testing, ultrasonic testing, acoustic emissions testing, <br /> or other systems of non-destructive testing. Comparison records and other records of inspections and <br /> tests must be maintained on site with the SPCC Plan. <br /> Immediately conduct all necessary integrity testing and maintain records on site as required. Update the <br /> SPCC plan to address this code section. <br /> 50. The SPCC plan does not include a discussion of Title 40 CFR §112.8(c)(8). Update the SPCC plan <br /> to include overfill prevention procedures and devices for the above ground petroleum storage containers <br /> and tanks at the facility. Install overfill prevention devices, as required, by the updated SPCC plan. <br /> 999. Title 40 CFR §112.7 - The SPCC plan does not follow the sequence specified in this section and <br /> does not have a cross-reference with the location of all requirements in the SPCC plan. Correct the <br /> SPCC plan and add a cross-reference with each required code section. <br /> Note <br /> 1. Complete and submit a copy of the Return to Compliance Certification form with a statement of how <br /> each violation was corrected, including supporting documentation, by August 20, 2011. <br /> ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE($122). <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> EHD Inspe Received By: Title: <br /> E 23- 2-003 Rev 08/10/10 CONTINUATION FORM <br />