My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
A
>
AURORA
>
1000
>
2200 - Hazardous Waste Program
>
PR0514266
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/19/2019 9:40:54 AM
Creation date
10/31/2018 9:20:20 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0514266
PE
2220
FACILITY_ID
FA0010274
FACILITY_NAME
SIMS METAL
STREET_NUMBER
1000
Direction
S
STREET_NAME
AURORA
STREET_TYPE
ST
City
STOCKTON
Zip
95206-1620
APN
15132022
CURRENT_STATUS
01
SITE_LOCATION
1000 S AURORA ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\A\AURORA\1000\PR0514266\COMPLIANCE INFO 2000 - 2016 .PDF
QuestysFileName
COMPLIANCE INFO 2000 - 2016
QuestysRecordDate
8/21/2017 10:44:31 PM
QuestysRecordID
3598839
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
265
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
11 <br />• <br />C7 <br />SAN JOAQUIN COUNTY <br />ENVIRONMENTAL HEALTH DEPARTMENT <br />600 East Main Street, Stockton, California 95202-3029 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sjgoy.or�q/ehd1 <br />HAZARDOUS WASTE PRQGRAM INC9)FfiT1nN Q=onpT <br />Fame: Sims Metal - REVISED 8/23111 Facility 1000 S. Aurora St., Stockton Inspection 08/17/2011 <br />Name: Address: <br />#V <br />y <br />Code Section <br />Date: <br />VIOLATIONS <br />HSC=CA Health & Safety Code; CCR=CA Code of Regulations; V=Violation7RV=Repeat Violation ✓ <br />0 <br />44 <br />CCR 66265.51 <br />Failed to: (a) prepare a contingency plan; (b) implement contingency plan <br />Z z 45 <br />X <br />CCR 66265,52 <br />Contingency plan incomplete <br />46 <br />CCR 66265.53(a) <br />Contingency plan not on site <br />Z a <br />47 <br />CCR 66265.55 <br />No emergency coordinator <br />c°a <br />48 <br />CCR 66265.560) <br />Failed to submit written incident report to the Department within 15 days <br />49 <br />X <br />I CCR 66265.16 <br />Personnel training records incomplete <br />0 <br />50 <br />CCR 66262.34(d) <br />Stored hazardous waste onsite greater than 180 days <br />E <br />51 <br />CCR 66262.34(d)(1) <br />Accumulated more than 6,000 kg of HW onsite at one time <br />Y <br />Failed to comply with Code of Federal Regulations 262.34(d), (e) & (f) <br />g <br />CFR 262.34(d)(5)(i) No emergency coordinator <br />0 <br />52 <br />CCR 66262.34(dX2) <br />CFR 262.34(d)(5)(4) No modified contingency plan <br />v <br />CFR 262.34(d)(5)(iii) Failed to train all employees on waste handling and emergency procedures <br />CFR 262,34 d 5 iv Failed to respond to a fire, spill or other release <br />53 <br />HSC 25244.4 <br />Failed to submit a report to the Department at least every two years <br />m <br />54 <br />HSC 25244,19 <br />Failed to conduct source reductionlevaluation of site and prepare waste minimization plan <br />55 <br />HSC 25244.21 <br />Failed to retain current (SB14) review and plan <br />56 <br />HSC 25160(b)(3) <br />Failed to submit TSDF manifest to the Department for Out -Of -State shipments <br />,i <br />57 <br />CCR 66262.20 <br />Failed to prepare manifests for transportation of hazardous waste <br />O <br />58 <br />CCR 66262.23(a) <br />Failed to: (1) complete, sign or date manifest; (2) obtain dated signature of transporter <br />_j <br />59 <br />X <br />CCR 66262.23(x)(4) <br />Failed to send generator manifest copies to the Department within 30 days <br />00 <br />60 <br />X <br />CCR 66262.40(a) <br />Failed to keep signed copy for 3 years <br />az <br />o' <br />61 <br />X <br />CCR 66262.42(a) <br />Failed to determine status of hazardous waste when manifest copy not received <br />g g <br />w <br />62 <br />X <br />CCR 66262.42(b) <br />Failed to file an exception report <br />u_ <br />63 <br />HSG 25160.2(b)(3) <br />Failed to keep a copy of the consolidated manifest for 3 years <br />64 <br />CCR 66266.81(a)(4)(B) Failed to retain copy of manifest or bill of lading for spent lead acid batteries <br />65 <br />HSC 25160.2(b)(4) <br />Consolidated manifest receipts failed to contain complete information <br />66 <br />HSC 25250.23 <br />Transported used oil and not registered as a hazardous waste hauler <br />0 <br />67 <br />CCR 66262.40(c) <br />Failed to retain waste analysis on site for 3 years <br />p <br />68 <br />CCR 66262.41(a) <br />Failed to submit Biennial Report to the Department <br />LU <br />69 <br />CCR 66262.40(b) <br />Failed to retain copy of Biennial Report/Exception Report for 3 years <br />70 <br />CCR 66265.77(x) <br />Failed to report releases to the Department <br />z <br />0 <br />71 <br />HSC 25160(d) <br />Transported hazardous waste without a manifest <br />a <br />72 <br />HSC 25163(x) <br />Transported hazardous waste or transferred HW to a transporter without valid registration <br />a <br />73 <br />1 <br />HSC 25160.2(cX2) <br />Offered ineligible waste streams to be transported using consolidated manifest <br />74 <br />CCR 66263.17(a) <br />Transported HW without receiving ID Number and registration cert from DTSC <br />75 <br />CCR 66263.23(b) <br />Delivered hazardous waste to an unauthorized facility <br />76 <br />CCR 66273.32(a) <br />Failed to notify the EPA RA to obtain an EPA ID # prior to accumulating >5000kg of UW <br />77 <br />CCR 66273.32(c) <br />Cathode Ray Tube (CRT) handier failed to notify DTSC 30 days prior to accepting offsite UW <br />78 <br />CCR 66273.33(a) <br />Failed to store UW batteries in a closed container and in a manner that prevents breakage and release to <br />the environment <br />ILL! <br />79 <br />CCR 66273.s3(b) <br />` Failed to: (1) store UW lamps in a closed container and in a manner that prevents breakage and release to the <br />I <br />to <br />environment, or 2 immediately clean and containerize any broken lamps or releases to the environment <br />Failed to store mercury containing UW in closed or airtight containers in a manner that prevents breakage <br />80 <br />CCR 66273.33(c) <br />and release to the environment, or failed to immediately clean and containerize any broken mercury <br />a x <br />containing UW or release to the environment <br />V)Failed <br />W81 <br />CCR 66273.33.5(a)(1 XB) <br />to: (1) store a UW electronic device in a manner that prevents breakage and release to the environment, or <br />W <br />2 immediate) clean and containerize an broken electronic device or release to the environment <br />> <br />82 <br />CCR 66273.33.5(b)(1 XB) <br />Failed to: (1) contain a CRT in a manner that prevents breakage and release to the environment, or (2) <br />jimmediate!y <br />clean and containerize any broken CRT or release to the environment <br />83 <br />X <br />CCR 66273.34 <br />Failed to label universal waste to identify type of universal waste. (a) Batteries, (b) Mercury containing <br />equipment, c Lamps, d Electronic devices, a CRTs, CRT glass <br />84 <br />CCR 66273.35 <br />(a) Stored UW onsite for more than 1 year, or (b) was unable to demonstrate the length of time the UW has <br />been accumulated from the date it became a waste or was received <br />85 <br />X <br />CCR 66273.39 <br />Failed to keep records of each shipment of universal waste according to this section <br />19991 <br />1 <br />Other: <br />See attached "Continuation - Official Inspection Report" for violation(s) not listed above. <br />UIC <br />Septic Sy <br />Serves > 20 personslday - Receives other than sanitary waste Dry wellslFrench Drains Onsite <br />Insp <br />- Phorm: Receive <br />! <br />Till <br />'etili <br />209 <br />468-3440 By: <br />EHD 2 Rev0118110 Page 2 HW INSPECTION REPORT <br />
The URL can be used to link to this page
Your browser does not support the video tag.