Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CHARTER
>
1675
>
2200 - Hazardous Waste Program
>
PR0514324
>
COMPLIANCE INFO
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/5/2018 10:43:31 AM
Creation date
10/31/2018 12:00:30 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
RECORD_ID
PR0514324
PE
2220
FACILITY_ID
FA0010429
FACILITY_NAME
DOUBLE A TRUCK SVC
STREET_NUMBER
1675
Direction
W
STREET_NAME
CHARTER
STREET_TYPE
WAY
City
STOCKTON
Zip
95206
APN
16337010
CURRENT_STATUS
02
SITE_LOCATION
1675 W CHARTER WAY D
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\C\CHARTER\1675\PR0514324\COMPLIANCE INFO\COMPLIANCE INFO.PDF
QuestysFileName
COMPLIANCE INFO
QuestysRecordDate
8/21/2013 8:00:00 AM
QuestysRecordID
2026292
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
86
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I..001 <br /> SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 600 East Main Street, Stockton, California 95202-3029 <br /> Telephone:(209)468-3420 Fax.(209)468-3433 Web:www.siaov.ora/ehd/ <br /> HAZARDOUS WASTE PROGRAM INSPECTION REPORT <br /> Fadlily Double A Truck Service Facility 1675 W. Charter Way, #D, Stockton oar chop 09/29/2010 <br /> Name: Address: <br /> # V y Code SeCUODVIOLATIONS <br /> HSC=CA Health 8 Safe Code CCR=CA Code of R ulations;V=ViolaUom RV-RepeatViolation v' <br /> 44 CCR 66265.51 Failed to:(a)prepare a contingency plan;(b)implement contingency plan <br /> ' 45 CCR 66265.52 Contingency plan incomplete <br /> 46 CCR 68265.53(a) Contingency plan not on site <br /> + 47 CCR 66285.55 No emergency coordinator <br /> 48 1 1 CCR 66265.560) Failed to submit written incident report to the Department within 15 days <br /> s <br /> 49 1 1 CCR 86265.16 Personnel paining records incomplete <br /> 50 X I CCR 66262.34(d) Stored hazardous waste onsite greater than 180 days <br /> e a 51 CCR 66262.34(d)(1) Accumulated more than 6,000 kg of HW onsite at one time <br /> c�y <br /> Failed to comply with Code of Federal Regulations 262.34(d),(e)8(1) <br /> p gg CFR 262.34(d)(5)(i)No emergency coordinator <br /> m S 52 CCR 66262.34(d)(2) CFR 262.34(d)(5)(ii)No modified contingency plan <br /> v CFR 262.34(d)(5)(iii)Failed to train all employees on waste handling and emergency procedures <br /> CFR 262.34 d 5 iv Failed to respond to a fires ill or other release <br /> 53 HSC 25244.4 Failed to submit a report to the Department at least every two years <br /> ■ 54 HSC 25244.19 Failed to conduct source reduction/evaluation of site and prepare waste minimization plan <br /> • 1551 1 1 HSC 25244.21 Failed to retain current(SB14)review and plan <br /> 56 HSC 26160(b)(3) Failed to submit TSDF manifest to the Department for Out-Of-State shipments <br /> 57 CCR 66262.20 Failed to prepare manifests for transportation of hazardous waste <br /> 58 CCR 66262.23(a) Failed to:(1)complete,sign or date manifest;(2)obtain dated signature of transporter <br /> 59 CCR 66262.23(a)(4) Failed to send generator manifest copies to the Department within 30 days <br /> q 60 CCR 66262.40(a) Failed to keep signed copy for 3 years <br /> 61 CCR 66262.42(a) Failed to determine status of hazardous waste when manifest copy not received <br /> 62 CCR 66262.42(b) Failed to file an exception report <br /> 63 HSC 25160.2(b)(3) Failed to keep a copy of the consolidated manifest for 3 years <br /> 64 CCR 66266.81(a)(4)(B) Failed to retain copy of manifest or bill of lading for spent lead add batteries <br /> 65HSC 25160.2(b)(4) Consolidated manifest receipts failed to contain complete information <br /> 66 HSC 25250.23 Transported used oil and not registered as a hazardous waste hauler <br /> 67 CCR 66262.40(c) Failed to retain waste analysis on site for 3 years <br /> 68 CCR 66262.41(a) Failed to submit Biennial Report to the Department <br /> 1691 1 1 CCR 66262.40(b) Failed to retain copy of Biennial Report/Exception Report for 3 years <br /> 1701 1 1 CCR 66265.77(a) Failed to report releases to the Department <br /> 71 HSC 25160(d) Transported hazardous waste without a manifest <br /> 72 HSC 25163(a) Transported hazardous waste or transferred HW to a transporter without valid registration <br /> 73 HSC 25160.2(c)(2) Offered ineligible waste streams to be transported using consolidated manifest <br /> 74 CCR 66263.17(a) Transported HW without receiving ID Number and registration can from DTSC <br /> 75 CCR 66263.23(b) Delivered hazardous waste to an unauthorized facility <br /> 76 CCR 66273.32(a) Failed to notify the EPA RA to obtain an EPA ID S prior to accumulating>5000kg of UW <br /> 77 CCR 66273.32(c) Cathode Ray Tube(CRT)handler failed to notify DTSC 30 days prior to accepting offsite UW <br /> 76 CCR 66273.33(a) Failetl to store UW batteries in a closed container and in a manner that prevents breakage and release to <br /> the environment <br /> 79 X CCR 66273.33(b) Failed to:(1)store UW lamps in a dosed container and in a manner that prevents breakage and release to the <br /> environment or 2 immediately dean and containenze any broken lamps or releases to the environment <br /> Failed to store mercury containing UW in closed or airtight containers in a manner that prevents breakage <br /> 80 CCR 66273.33(c) and release to the environment,or failed to immediately dean and containerize any broken mercury <br /> J <br /> containing UW or release to the environment <br /> Failetl to:(1)store a UW electronic device in a manner that prevents breakage and release to the environment,or <br /> 61 CCR 66273.33.5(a)(1)(8) 2 immediate) dean and containerize an broken electronic device or release to the environment <br /> ZFailed to:(1)contain a CRT in a manner that prevents breakage and release to the environment,or(2) <br /> 82 1 1 CCR 66273.33.5(b)(1)(B) immediately clean and containerize any broken CRT or release to the environment <br /> 83 1 1 CCR 66273.34 Failed to label universal waste to identify type of universal waste. (a)Batteries,(b)Mercury containing <br /> e ui ment, c Lamps, d Electronic devices, a CRTs CRT glass <br /> 84 1 1 CCR 66273.35 (a)Stored UW onsite for more than 1 year,or(b)was unable to demonstrate the length of time the UW has <br /> been accumulated from the date it became a waste or was received <br /> 851 1 1 CCR 66273.39 Failed to keep records of each shipment of universal waste according to this section <br /> 999 1 1 Other: See attached"Continuation-Official Inspection Report"for violation(s)not listed above. <br /> U CI sew ystem: Serves>20 persons/day, 11 Recelws other than sari to iDrywellisffirenchDrainsOnsite <br /> 1" P^O"`- Received Tdie: <br /> i! 209 468-9848 By: <br /> EHD 22-02-004 R"01/8110 a HW INSPECTION REPORT <br />
The URL can be used to link to this page
Your browser does not support the video tag.