My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CLARK
>
3927
>
2200 - Hazardous Waste Program
>
PR0514138
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/28/2019 4:22:31 PM
Creation date
10/31/2018 12:27:35 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0514138
PE
2230
FACILITY_ID
FA0010034
FACILITY_NAME
PNP Stockton #80
STREET_NUMBER
3927
Direction
E
STREET_NAME
CLARK
STREET_TYPE
DR
City
STOCKTON
Zip
95215
APN
17917109
CURRENT_STATUS
01
SITE_LOCATION
3927 E CLARK DR
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\C\CLARK\3927\PR0514138\COMPLIANCE INFO 1991 - 2011.PDF
QuestysFileName
COMPLIANCE INFO 1991 - 2011
QuestysRecordDate
11/14/2017 5:47:21 PM
QuestysRecordID
3727153
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
1543
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Table 4 <br /> Summary of CCR Requirements <br /> Pick-N-Pull <br /> Stockton,California <br /> Code Section Requirement Comments <br /> 66265.193(e)(2)(B) Vaults must be designed or operated to prevent run—on and infiltration of <br /> precipitation into the secondary containment unless the collection system has <br /> sufficient excess capacity,in addition to that required in Subsection(e)(1)(A)of this NA <br /> section,to contain run-on and infiltration of precipitation from a 25 year,24 hour <br /> rainfall event. <br /> 66265.193(e)(2)(C) Vaults must be constructed with chemical resistant water stops in place at all joints NA <br /> 66265.193(e)(2)(D) Vaults must be provided with an impermeable interior coating or lining that is <br /> compatible with the waste being transferred,stored or treated and that will prevent NA <br /> migration of waste into the concrete. <br /> 66265.193(e)(2)(F) provided with an exterior moisture barrier or be otherwise designed or operated to <br /> prevent migration of moisture into the vault if the vault is subject to hydraulic NA <br /> pressure. <br /> 66265.193(e)(3)(A) Double-walled tanks shall be:designed as an integral structure(i.e.,an inner tank <br /> within an outer shell)so that any release from the inner tank is contained by the outer Compliant <br /> shell; <br /> 66265.193(e)(3)(B) Double-walled tanks shall be:protected,if constructed of metal,from both corrosion <br /> of the primary tank interior and the external surface of the outer shell;and XLPE <br /> 66265.193(e)(3)(C) Double-walled tanks shall be:provided with a built-in,continuous leak detection <br /> system capable of detecting a release within 24 hours or at the earliest practicable <br /> time,if the owner or operator can demonstrate to the Department,and the Daily Visual Inpsections <br /> Department concurs,that the existing leak detection technology or site conditions will <br /> not allow detection of a release within 24 hours. <br /> 66265.193(f) Ancillary equipment shall be provided with full secondary containment(e.g.trench, <br /> jacketing,double-walled piping)that meets the requirements of subsections(b)and Piping is above ground. <br /> (c)of this section except for: <br /> 66265.193 1 aboveground piping that are visually inspected for leaks on a daily basis Compliant <br /> 66265.193(f)(2) welded flanges,welded joints,and welded connections that are visually inspected for Compliant <br /> leaks on a daily basis <br /> 66265.193(f)(3) sealless or magnetic coupling pumps and sealless valves,that are visually inspected NA <br /> for leaks on a daily basis and <br /> 66265.193(f)(4) pressurized above ground piping with automatic shut-off devices that are visually Compliant-pumped/gravity drained <br /> inspected for leaks on a daily basis. <br /> Updated:7/18/18 <br /> Reviewed by:MMC 7/27/18 <br /> Page 3 of 3 <br />