COMPLIANCE INFO_PRE 2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CLARK
>
3927
>
2200 - Hazardous Waste Program
>
PR0514138
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/28/2019 4:22:31 PM
Creation date
10/31/2018 12:27:35 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0514138
PE
2230
FACILITY_ID
FA0010034
FACILITY_NAME
PNP Stockton #80
STREET_NUMBER
3927
Direction
E
STREET_NAME
CLARK
STREET_TYPE
DR
City
STOCKTON
Zip
95215
APN
17917109
CURRENT_STATUS
01
SITE_LOCATION
3927 E CLARK DR
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\C\CLARK\3927\PR0514138\COMPLIANCE INFO 1991 - 2011.PDF
QuestysFileName
COMPLIANCE INFO 1991 - 2011
QuestysRecordDate
11/14/2017 5:47:21 PM
QuestysRecordID
3727153
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
1543
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Table 4 <br /> Summary of CCR Requirements <br /> Pick-N-Pull <br /> Stockton,California <br /> Code Section Requirement Comments <br /> 66265.192(k)(4) Description and evaluation of any leak detection equipment. <br /> Used Oil/Waste Antifreeze(01-O4/A1-A4)-visual.Customer Drop-off-level gauge/overfill shut-off. <br /> 66265.192(k)(5) Description and evaluation of any corrosion protection equipment,devices or NA-XLPE/Concrete encased or painted. <br /> material. <br /> 66265.192(k)(6) Description of any spill prevention or overfill equipment <br /> Used Oil/Waste Antifreeze(01-04/A1-A4)-visual.Customer Drop-off-level gauge/overfill shut-off.G <br /> 66265.192(k)(7) description and evaluation of secondary containment for the tank system(secondary <br /> containment must meet minimum standards as specified in subsections 0)(1)through <br /> 0)(3)of this section)including applicable secondary containment for ancillary XLPE for tanks;Steel for oil filter. <br /> equipment as required in subsection 66265.193(f); <br /> 66265.192(k)(8) Hazardous characteristics of the wastes that have been handled. Used Oil,-combustible,toxic.waste Antifreeze-toxic <br /> 66265.192(k)(1 1Estimated remaining service life of the tanks stem Recommend replacement on case by case evaluation. <br /> 66265.193(b)(1) Secondary containment systems shall be designed,installed and operated to prevent <br /> any migration of wastes or accumulated liquid out of the system to the soil,ground XLPE for tanks;Steel for oil filter. <br /> water,or surface water at any time during the use of the tank system. <br /> 66265.193(b)(2) Secondary containment systems shall be Capable of detecting and collecting releases visual Inspection <br /> and accumulated liquids until the collected material is removed. <br /> 66265.193(c)(1) Secondary systems shall be at a minimum:constructed of or lined with materials that <br /> are compatible with the waste(s)to be placed in the tank system and shall have <br /> sufficient strength to prevent failure due to pressure gradients(including static head <br /> and external hydrological forces),physical contact with the waste to which they are Compliant <br /> exposed,climatic conditions,the stress of installation,and the stress of daily <br /> operation(including stresses from nearby vehicular traffic). <br /> 66265.193(c)(2) Secondary systems shall be at a minimum:Placed on a foundation or base capable <br /> of providing support to the secondary containment system and resistance to pressure Concrete slab <br /> gradients above and below the system and capable of preventing failure due to <br /> settlement compression,or uplift. <br /> 66265.193(c)(3) Secondary containment systems shall be at a minimum:provided with a leak <br /> detection system that is designed and operated so that it will detect the failure of <br /> either the primary or secondary containment structure or any release of hazardous <br /> waste or accumulated liquid n the secondary containment system within 24 hours,or Visual daily inspections <br /> at the earliest practicable time if the existing detection technology or site conditions <br /> will not allow detection of a release within 24 hours. <br /> 66265.193(c)(4) Secondary containment systems shall be at a minimum:Sloped or otherwise <br /> designed or operated to drain and remove liquids resulting from leaks,spills,or <br /> precipitation.Spilled or leaked waste and accumulated precipitation shall be removed <br /> from the secondary containment system within 24 hours,or in as timely a manner as visual inspection-immediate removal if identified <br /> is possible to prevent harm to human health or the environment,if removal of the <br /> released waste or accumulated precipitation cannot be accomplished within 24 hours <br /> 66265.193(d) Secondary containment for tanks shall include one or more of the following devices: <br /> 1.A liner external to the tank NA <br /> 2.A vault NA <br /> 3.A double walled tank;or NA <br /> 4.Anequivalent device as approved by the Department Compliant-Use Oil/Waste Antifreeze <br /> 66265.193(e)(2)(A) Vaults must be designed or operated to contain 100 percent of the capacity of the NA <br /> largest tank within its boundary. <br /> Page 2 of 3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.