Laserfiche WebLink
Page 2 of 6 <br />DEC 0 4 2015 <br />San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sj <br />EKwiRONMENTAL oov.or /q ehd <br />HEALTH DEPARTIVIGNToveground <br />Petroleum Storage Act Inspection Report <br />Facility Name: <br />Lawrence Livermore National Lab - Site 300 <br />Facility Address: <br />15999 W CORRAL HOLLOW RD Trac <br />FDate: <br />September <br />30 <br />2015 <br />General Requirements for SPCC Plans <br />613 <br />CFR <br />112.7(e) <br />Failed <br />Failed <br />to conduct inspections or maintain records for 3 years <br />to train personnel on discharge prevention <br />o <br />V <br />❑ <br />R <br />o <br />COS <br />614 <br />CFR 112.7(f)(1) <br />u V ❑ R ❑ <br />COS <br />615 <br />CFR <br />112.7(0(2) <br />Failed <br />Failed <br />to designate a person accountable for discharge prevention <br />to schedule and conduct discharge prevention briefings at least annually <br />■ <br />V <br />o <br />R <br />u <br />COS <br />616 <br />CFR 112.7(f)(3) <br />o V u R o <br />COS <br />617 <br />CFR <br />112.7(8) <br />Plan failed to address security of site and valves, lock out/tag out, and lighting <br />■ <br />V <br />o <br />R <br />❑ <br />COS <br />618 <br />CFR <br />112.7(h)(1) <br />Loading/unloading rack containment system not properly sized <br />❑ <br />V <br />❑ <br />R <br />❑ <br />COS <br />619 <br />CFR <br />112.7(h)(2) <br />Failed <br />to provide vehicular departure system loading and unloading racks <br />o <br />V <br />❑ <br />R <br />u <br />COS <br />E• 620 <br />CFR <br />112.7(h)(3) <br />Failed <br />to inspect lowermost drains and outlets prior to filling and departure of vehicles <br />o <br />V <br />OR <br />o <br />COS <br />621 <br />CFR <br />112.7(1) <br />Failed <br />to evaluate field constructed container for brittle fracture and take appropriate action <br />❑ <br />V <br />❑ <br />R <br />❑ <br />COS <br />622 <br />CFR <br />112.7Q) <br />Failed <br />to include discussion of conformance to discharge prevention and containment procedures <br />a <br />V <br />u <br />R <br />o <br />COS <br />SPCC Plan Requirements for Onshore Facilities (excluding production facilities) <br />701 <br />CFR <br />112.8(b)(2) <br />Failed <br />to use manual open-and-closed design valves for the drainage of diked areas <br />o <br />V <br />❑ <br />R <br />❑ <br />COS <br />702 <br />CFR 112.8(b)(3), <br />112.8(b)(4) <br />Failed <br />to design facility drainage system from undiked areas to retain in the facility <br />o <br />V <br />❑ <br />R <br />o <br />COS <br />703 <br />CFR <br />112.8(b)(5) <br />Failed <br />to provide two lift pumps for more than one continuous treatment unit <br />o <br />V <br />o <br />R <br />a <br />COS <br />704 <br />CFR <br />112.8(c)(2) <br />Diked <br />area Is not sufficiently impervious to contain discharged oil <br />o <br />V <br />a <br />R <br />❑ <br />COS <br />705 <br />CFR <br />112.8(c)(1) <br />Container not compatible with oil stored and/or storage conditions <br />o <br />V <br />OR <br />❑ <br />COS <br />706 <br />CFR <br />112.8(c)(2) <br />Failed <br />to provide and maintain adequate secondary containment <br />❑ <br />V <br />o <br />R <br />❑ <br />COS <br />707 <br />CFR <br />112.8(c)(3)(i) <br />Failed <br />to keep containment bypass valves closed when not draining rainwater <br />❑ <br />V <br />❑ <br />R <br />a <br />COS <br />708 <br />CFR <br />112.8(c)(3)(h) <br />Failed <br />to inspect retained rainwater prior to discharge <br />❑ <br />V <br />❑ <br />R <br />o <br />COS <br />709 <br />CFR <br />112.8(c)(3)(iii) <br />Failed <br />to open and close bypass valve to drain rainwater under responsible supervision <br />o <br />V <br />❑ <br />R <br />❑ <br />COS <br />710 <br />CFR <br />112.8(c)(3)(iv) <br />Failed <br />to maintain records of drainage from diked areas <br />o <br />V <br />❑ <br />R <br />a <br />COS <br />711 <br />CFR <br />112.8(c)(5) <br />Failed <br />to provide corrosion protection for partially buried tanks <br />o <br />V <br />❑ <br />R <br />❑ <br />COS <br />712 <br />CFR <br />112.8(c)(6) <br />Failed <br />to perform tank inspections that take into account size, configuration, and design <br />❑ <br />V <br />❑ <br />R <br />u <br />COS <br />713 <br />CFR <br />112.8(c)(6) <br />Failed <br />to perform scheduled tank tests and Inspections by appropriately qualified personnel <br />■ <br />V <br />OR <br />o <br />COS <br />714 <br />CFR <br />112.8(c)(6) <br />Failed <br />to test and inspect containers by appropriately qualified personnel after material repairs <br />❑ <br />V <br />o <br />R <br />a <br />COS <br />715 <br />CFR <br />112.8(c)(7) <br />Failed <br />to provide effective leakage control through defective internal heating coils <br />❑ <br />V <br />❑ <br />R <br />o <br />COS <br />716 <br />CFR <br />112.8(c)(8)(I-iv) <br />Failed <br />to provide each container with a high level monitoring device <br />❑ <br />V <br />❑ <br />R <br />❑ <br />COS <br />717 <br />CFR <br />112.8(c)(8)(v) <br />Failed <br />to regularly test liquid level sensing devices to ensure proper operation <br />in <br />V <br />❑ <br />R <br />❑COS <br />718 <br />CFR <br />112.8(c)(9) <br />Failed <br />to observe effluent treatment frequently enough to detect potential discharge <br />a V u R o <br />COS <br />719 <br />CFR <br />112.8(c)(10) <br />Failed <br />to promptly correct visible discharges and/or remove accumulations of oil in diked areas <br />❑ <br />V <br />a <br />R <br />o <br />COS <br />720 <br />CFR <br />112.8(c)(11) <br />Failed <br />to provide sufficient secondary containment capacity for mobile or portable containers <br />o <br />V <br />o <br />R <br />o <br />COS <br />721 <br />CFR <br />112.8(c)(11) <br />Failed <br />to locate mobile or portable containers to prevent discharge <br />❑ <br />V <br />❑ <br />R <br />u <br />COS <br />722 <br />CFR <br />112.8(d)(1) <br />Failed <br />to take corrective action on buried piping when exposed for any reason <br />o <br />V <br />o <br />R <br />❑ <br />COS <br />Received by <br />(initial):�i/e <br />Inspector: <br />STACY RIVERA, Senior REHS� <br />Phone: <br />(209) 468-3440 <br />Date: <br />09/30/2015 <br />Page 2 of 6 <br />