My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
L
>
LOOMIS
>
3018
>
2200 - Hazardous Waste Program
>
PR0540222
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/9/2019 11:38:00 AM
Creation date
11/1/2018 11:53:14 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO_PRE 2019
FileName_PostFix
PRE 2019
RECORD_ID
PR0540222
PE
2220
FACILITY_ID
FA0014687
FACILITY_NAME
OAK HARBOR FREIGHT STOCKTON #038
STREET_NUMBER
3018
Direction
E
STREET_NAME
LOOMIS
STREET_TYPE
RD
City
STOCKTON
Zip
95205
APN
17910007
CURRENT_STATUS
01
SITE_LOCATION
3018 E LOOMIS RD
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\L\LOOMIS\3018\PR0540222\COMPLIANCE INFO.PDF
QuestysFileName
COMPLIANCE INFO
QuestysRecordDate
10/25/2016 10:23:39 PM
QuestysRecordID
3005571
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
135
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209) 468-3420 Fax:(209) 468-3433 Web:www.sjgov.org/ehd <br /> Small Quantity Hazardous Waste Generator Inspection Report <br /> Facility Name: Facility Address: Date: <br /> Oak Harbor Freight Stockton#038 3018 E LOOMIS RD STOCKTON February 10 2016 <br /> Universal Waste <br /> 707 HSC 25201.16(e) Failed to manage aerosol cans in a manner that prevents the unauthorized release of waste o V o R o COS <br /> 708 HSC 25201.16(f) Failed to properly manage containers of waste aerosol cans o V o R o COS <br /> 709 HSC 25201.16(g) Failed to store used aerosol cans in an accumulation container o V o R o COS <br /> 710 HSC 25201.16(h)(4) No written operating procedure for aerosol can processing o V o R o COS <br /> 711 HSC 25201.160) Failed to submit or amend notification for aerosol can processing o V o R o COS <br /> 712 CCR 66273.34 Failed to label universal waste to identify type of universal waste o V o R o COS <br /> 713 CCR 66273.35 Stored UW onsite greater than one year or was unable to demonstrate the time UW has been stored o V o R o COS <br /> 714 1 CCR 66273.36 Failed to train employees and maintain records on UW handling and emergency procedures o V o R o COS <br /> 715 CCR 66273.39 Failed to keep complete records of each shipment of universal waste for three years o V o R o COS <br /> Other Violations <br /> 3010 See below Unlisted Administration/Documentation violation o V o R o COS <br /> 3020 See below Unlisted Training violation o V o R o COS <br /> 3030 See below Unlisted Operations/Maintenance violation o V o R o COS <br /> 3040 See below Unlisted Release/Leaks/Spills violation o V o R o COS <br /> 3050 See below Unlisted Abandonment/Illegal Disposal/Unauthorized Treatment violation o V o R o COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item # Remarks <br /> 103 CCR 66262.34(d)(2) No modified contingency plan. <br /> An emergency coordinator and modified contingency plan information is lacking. There must be at least one <br /> emergency coordinator on site or on call to coordinate emergency response measures, and the following information <br /> must be posted by a phone. the name and phone number of the emergency coordinator; location of fire extinguishers, <br /> spill control equipment, and if present, fire alarm, and the phone number of the fire department, unless the facility has <br /> a direct alarm. Immediately appoint an emergency coordinator and post the required information by a phone. A form <br /> is provided that can be used for this purpose. <br /> This is a Class II violation. <br /> 105 CCR 66262.34(d)(2) Failed to train employees on waste handling and emergency procedures. <br /> At the time of inspection, it could not be demonstrated (not necessarily documented) that employees who handle <br /> hazardous waste were properly trained. Mr. Tim Baird indicated no one on the facility has hazardous waste training <br /> The generator must ensure that all employees who handle hazardous waste are thoroughly familiar with proper waste <br /> handling and emergency procedures. Provide proof of training to the EHD for employees whose responsibilities <br /> include hazardous waste. <br /> This is a Class II violation. <br /> Page 3 of 8 <br />
The URL can be used to link to this page
Your browser does not support the video tag.