My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SITE INFORMATION AND CORRESPONDENCE
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
A
>
ALPINE
>
1624
>
2900 - Site Mitigation Program
>
PR0009012
>
SITE INFORMATION AND CORRESPONDENCE
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/1/2018 10:03:55 PM
Creation date
11/1/2018 11:57:45 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
SITE INFORMATION AND CORRESPONDENCE
RECORD_ID
PR0009012
PE
2960
FACILITY_ID
FA0004532
FACILITY_NAME
FRMR KEARNEY-KPF FACILITY
STREET_NUMBER
1624
Direction
E
STREET_NAME
ALPINE
STREET_TYPE
AVE
City
STOCKTON
Zip
95205
APN
11708006-09
CURRENT_STATUS
01
SITE_LOCATION
1624 E ALPINE AVE
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
WNg
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
555
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
•' MONITORING AND REPOR*b PROGRAM NO.5-01-269 Revision 1 -3- <br /> ' KEARNEY-NATIONAL,INC.AND UPRIGHT CONSTRUCTION <br /> FORMER KEARNEY-KPF FACILITY <br /> GROUNDWATER TREATMENT AND DISPOSAL SYSTEM <br /> SAN JOAQUIN COUNTY <br /> EXTRACTION WELL MONITORING T <br /> The volume of extracted groundwater also shall be provided in quarterly monitoring reports as <br /> well as monthly reports. Sample collection and analysis shall follow standard EPA protocol. <br /> Extraction wells shall be monitored according to the following program: <br /> Type of Sampling Reporting <br /> Constituent Units Sample Frequencv Frequencv <br /> Volatile Organic Compounds µg/1 Grab Quarterly Quarterly <br /> Electrical Conductivity(Field) µmhos/cm Grab Quarterly Quarterly T <br /> Total Dissolved Solids mg/l Grab Quarterly Quarterly K <br /> pH (Field) pH units Grab Quarterly Quarterly <br /> Temperature (Field) 'Celsius Grab Quarterly Quarterly <br /> Total Volume of Water Extracted Gallons Continuous Monthly Monthly <br /> Extraction Rate at Time of Sampling gpm Grab Monthly Monthly <br /> Average Extraction Rate (last 7 days) gpm Continuous Monthly Monthly <br /> Pressure at Time of Sampling psig Grab Monthly Monthly <br /> Water Level 0.01 feet msl Grab Monthly Monthly A <br /> 1 Required analytical method shall be either USEPA Method 8260B or 8021B. The maximum detection limits must <br /> meet the lowest reporting limit in the State Water Resources Control Board Policy for Implementation of Toxics <br /> Standard for Inland Surface Waters,Enclosed Bays and Estuaries of California(Appendix 4,minimum levels)or <br /> Department of Health Services detection limits for purposes of reporting(DLRs). <br /> GROUNDWATER MONITORING <br /> All monitoring wells and piezometers shall be monitored according to the requirements listed in j <br /> Monitoring and Reporting Program No. R5-2002-XXXX, unless the well or piezometer is being 1 <br /> used as an extraction or injection well, in which case sampling shall be in accordance with the <br /> extraction or injection well monitoring listed in this MRP. <br /> REPORTING <br /> In reporting monitoring data, the Discharger shall arrange the data in tabular form so that the T <br /> date, sample type (e.g., influent, effluent, etc.), and reported analytical result for each sample are 1 <br /> readily discernible. The data shall be summarized in such a manner to clearly illustrate <br /> compliance with waste discharge requirements and spatial or temporal trends, as applicable. The <br /> results of any monitoring done more frequently than required at the locations specified in the <br /> MRP shall also be reported to the Regional Board. <br /> As required by the California Business and Professions Code Sections 6735, 7835, and 7835.1, <br /> all reports shall be prepared by or under the direct supervision of a Registered Engineer or <br /> Geologist and signed by the registered professional. <br />
The URL can be used to link to this page
Your browser does not support the video tag.