CALIFORNIA REGIONAL WATER QUALITY CONTROL BOARD
<br /> CENTRAL VALLEY REGION
<br /> MONITORING AND REPORTING PROGRAM NO. 5-01-269,Revision 2
<br /> CALIFORNIA WATER CODE SECTION 13267
<br /> FOR
<br /> KEARNEY-NATIONAL, INC. AND
<br /> ALPINE BUILDERS, INC.
<br /> FORMER KEARNEY-KPF FACILITY
<br /> GROUNDWATER TREATMENT AND DISPOSAL SYSTEM
<br /> SAN JOAQUIN COUNTY
<br /> This monitoring and reporting program (MRP) incorporates requirements for monitoring of the treatment
<br /> process and effluent. This MRP is issued by the Executive Officer of the California Regional Water
<br /> Quality Control Board, Central Valley Region (Regional Board)pursuant to California Water Code
<br /> Section 13267. The Discharger shall not implement any changes to this MRP unless and until a revised
<br /> MRP is issued by the Executive Officer. This MRP revises the requirements listed in MRP No.
<br /> 5-01-269, Revision 1 issued on 16 September 2002. Specific sample station locations shall be approved
<br /> by Regional Board staff prior to implementation of sampling activities.
<br /> All samples shall be representative of the volume and the nature of the discharge and matrix of the
<br /> sampled medium. The time, date, and location of each grab sample shall be recorded on the sample
<br /> chain of custody form.
<br /> Field testing instruments (such as those used to test pH and dissolved oxygen)may be used provided
<br /> that:
<br /> 1. The operator is trained in proper use and maintenance of the instruments;
<br /> 2. The instruments are calibrated prior to each monitoring event;
<br /> 3. Instruments are serviced and/or calibrated by the manufacturer at the recommended frequency;
<br /> and
<br /> 4. Field calibration reports are provided with the appropriate monitoring report.
<br /> As shown on Attachment 1 and listed below, the Site has 19 shallow zone monitoring wells (MWs), 19
<br /> intermediate zone MWs, six deep zone MWs, and one former production well. Of these 45 wells, one
<br /> deep well (INJ-1), three shallow MWs (KPS-5, TP-lA and TP-3A), four shallow MWs (SMW-1;
<br /> SMW-2, SMW-4, and SMW-5), and/or two intermediate MWs (KEW-lU and KEW-2U) may be used as
<br /> injection wells. Five intermediate zone MWs (KEW-3U, KEW-4U, KI-3, KI-5, and KI-12) are used as
<br /> extraction wells.
<br /> Shallow Zone Monitor Wells: B-1, B-4, B-5, KPS-5, KS-1, KS-2, KS-4,KS-5, KS-6, KS-8,
<br /> SMW-1, SMW-2, SMW-3, SMW-4, SMW-5, SMW-6, TP-lA,
<br /> TP-2A, and TP-3A
<br /> Intermediate Zone Monitor Wells: KI-2, KI-3, KI-4,KI-5, KI-6, KI-8, KI-11, KI-12,KI-13,KI-14,
<br /> KI-16, KI-17,KEW-IU,KEW-2U,KEW-3U, KEW-4U,KPL-5,
<br /> KPU-5, and PX-1
<br /> Deep Zone Monitor Wells: DMW-1,INJ-1,KD-1,KD-4, KD-5, and KD-6
<br /> Production Well: SPW
<br />
|