My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
L
>
LOUISE
>
500
>
2200 - Hazardous Waste Program
>
PR0220082
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/20/2021 2:12:46 PM
Creation date
11/1/2018 12:04:10 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0220082
PE
2220
FACILITY_ID
FA0000214
FACILITY_NAME
PILKINGTON NORTH AMERICA INC PLANT 10
STREET_NUMBER
500
Direction
E
STREET_NAME
LOUISE
STREET_TYPE
AVE
City
LATHROP
Zip
95330-9739
CURRENT_STATUS
01
SITE_LOCATION
500 E LOUISE AVE
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
FilePath
\MIGRATIONS\L\LOUISE\500\PR0220082\COMPLIANCE INFO 1989 - 1992.PDF
QuestysFileName
COMPLIANCE INFO 1989 - 1992
QuestysRecordDate
9/22/2017 9:10:01 PM
QuestysRecordID
3256138
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
954
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� Document Number: 909 R 5003 Document Number: 909 R 5003 <br /> Procedure Rev: 12 Date: 1/22/13 Procedure Rev: 12 Date: 1/22113 <br /> EMERGENCY RESPONSE PROCEDURES EMERGENCY RESPONSE PROCEDURES <br /> Secondary Storage Areas <br /> Generally one to two different types of petroleum based products are stored within the <br /> Lehr tube Storage Area boiler room. Storage is limited to actually that being used. Several different types of <br /> water treatment (for RO system & boiler) chemicals are also found here. The boiler <br /> Drums and pales of petroleum based products are stored here for use in and around room also has a satellite collection point for waste oil. <br /> the lehr. Generally, inventory is limited to that actually needed, Approximately, eight <br /> 55 gallon drums of different materials are in use along with several lubricants that are Batch House Storage Room Bast Butler Buildin <br /> in either 5 gallon pales or small kegs. A satellite collection point for waste oil and oily <br /> waste solids are located here. Certain materials are used as glass colorant chemicals. Stored in these locations are <br /> nickel oxide, Iron Oxide, Selenium, Soda Ash, Silica Sand, cobalt oxide, sodium <br /> nitrate, Sodium Sulfate, Titanium Dioxide, Limestone, Dolomite, and a cobalt oxide <br /> Maintenance Shop and Satellite Maintenance Cages containing mixture(material 98).When melted into the glass product,their hazardous <br /> properties are no longer manifest. The materials are purchased as dry powders in <br /> The facility has one main maintenance shop and several smaller satellite shops. The paper bags or fiber drums. <br /> main shop generally has one to six 55 gallon drums of petroleum based product as <br /> well as smaller quantities of other materials associated with the maintenance of a Hazardous Material Bulk Storage <br /> manufacturing facility. <br /> The satellite shops serve specific areas of the facility. Small quantities of petroleum Sulfur Dioxide <br /> based products may be stored in these locations. The satellite locations generally A sulfur dioxide dispensing port is located outside on the north side of the lehr. Two <br /> have several one and five gallon containers or kegs of product. A majority of the shops 500 Ib cylinders are located here, one for dispensing and one on standby.There is a <br /> have Safely-Kleen solvent based parts washers. third two 500 lb cylinder located about 50 feet away as a back up(not connected). <br /> Main Storeroom Chlorine <br /> The main storeroom is located within the main facility,just behind the general offices. Cylinders are located at each of the cooling towers and at the sanitary packaged <br /> Materials generally stored within this storeroom, aerosol cans of maintenance treatment plant. One to two 150 Ib. cylinders are usually found at the cooling tower <br /> products,small containers(half gallon,paints)of petroleum based products. south of the boiler room and east of the furnace. Two 150 Ib. cylinders serve the <br /> packaged sanitary treatment plant. Chlorine gas is used continuously to disinfect the <br /> Water Treatment Chemicals storage buildin effluent from the treatment plant and at the cooling towers. <br /> This facility is located by the !East Cooling tower 1 Marley tower, and serves as the Propane Gas <br /> storage area for chemicals that are used for water treatment.The main chemicals that <br /> are stored in this building are Hydrogen Peroxide,Tolytriazol,and Sodium Molybdate. Propane gas is used as fuel in forklifts and as standby fuel for the furnace. The main <br /> propane tank farm(standby fuel)consists of four 40,000 gallon tanks and one 30,000 <br /> gallon tank located to the rear of the facility. In addition to these,a 1,000 gallon tank is <br /> Boiler Roam <br /> located in the same area and used to fuel equipment. <br /> Document in and SettingslnlrmUcal SettingsWemporary Intemet FileskContent.OutlookUQ9W31 RY CAPA Document in and SeltinKsliltranll.ocal SettingsNremporary Internet Fi1es\Contcnt.0utiook1JQ9W3I RYTAPA <br /> CCR 66265 55.doc Page 35 of 69 CCR 66265 55.doc Page 36 or 69 <br /> Paper Copies are Not Controlled unless stamped In RED-Controlled DocumarI Controlled Version appears In Q59000 database_ Payer Copies are Not Controlled unless stamped In RED`Controlled Document,Controlled Version appear In 059000 database. <br /> Copies withouta RED"Connoged 0ocumenr stamp will be CBSCLETE 24 hours from 6111201!1:57 Pid Copies mUrouts RED Tontrolied Documenr'stamp vn0 be OBSOLETE 24 hourstrom 611177014 1:57 PN <br />
The URL can be used to link to this page
Your browser does not support the video tag.