My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
N
>
NOWELL
>
26200
>
2200 - Hazardous Waste Program
>
PR0513888
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/9/2019 11:43:55 AM
Creation date
11/1/2018 1:17:54 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0513888
PE
2220
FACILITY_ID
FA0009531
FACILITY_NAME
UFP Thornton LLC
STREET_NUMBER
26200
STREET_NAME
NOWELL
STREET_TYPE
Rd
City
Thornton
Zip
95686
CURRENT_STATUS
01
SITE_LOCATION
26200 Nowell Rd
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\N\NOWELL\26200\PR0513888\COMPLIANCE INFO 1989 - 2015.PDF
QuestysFileName
COMPLIANCE INFO 1989 - 2015
QuestysRecordDate
11/21/2017 12:29:48 AM
QuestysRecordID
3732620
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
211
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Yes No Comment <br /> 90 Day Accumulation in Tanks (cont. ) <br /> (Section 66262.34) <br /> Has the generator obtained and kept on file at <br /> the facility a written assessment reviewed and <br /> certified by an engineer in accordance with <br /> section 66270.11(d) by: [66265.191(a)-] <br /> (1) January 12, 1988 for tanks containing RCRA <br /> HW, unless the generator is a conditionally <br /> exempt SQG per 40 CFR 261.5 or a SQG per <br /> 40 CFR 265.203.? or <br /> (2) July 1, 1992, for tanks containing only <br /> non-RCRA HW, and tanks containing RCRA HW if the <br /> generator is a conditionally exempt SQG per <br /> 40 CFR 261.5 or a SQG per 40 CFR 265.201?, or <br /> If the tank stores waste that became hazardous <br /> after the above dates, within 12 months of date <br /> that the waste becomes a hazardous waste? <br /> [66265.191(c) ] <br /> Did the assessment consider all required <br /> information, including: [66265.191(b)-] <br /> (1) Original design standard(s)? <br /> (2) HW characteristics? <br /> (3) Existing corrosion protection? <br /> (4) Documented age of tank, if known? — <br /> (5) Results of leak test, internal <br /> inspection, or other tank examination? <br /> If assessment conducted for 66265.191(x) found <br /> that the tank is leaking or unfit for use, did <br /> the generator fly with 66265.196 (see <br /> page 9)? [66265.191(4) ] <br /> Design and installation of new tank systems: <br /> Has the generator obtained and kept on file at <br /> the facility a written assessment reviewed and <br /> certified by an engineer in accordance with <br /> section 66270.11(d) prior to placing the tank <br /> system in service? [66265.192(x) ] <br /> Did the assessment consider all required <br /> information, including: [66265.192(a)-] <br /> (1) Original design standard(s)? <br /> (2) HW characteristics? <br /> (3) Factors affecting corrosion and needed <br /> external corrosion protection? <br /> (4) Protection against vehicular traffic if an <br /> underground tank? <br /> (5) Foundation strength, anchoring, and frost <br /> heave protection? <br /> Revised 7/15/91. Page 11 <br />
The URL can be used to link to this page