My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MARIPOSA
>
1754
>
2200 - Hazardous Waste Program
>
PR0514047
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/14/2025 1:33:57 PM
Creation date
11/1/2018 1:52:56 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0514047
PE
2220
FACILITY_ID
FA0009818
FACILITY_NAME
HARLEY MURRAY INC
STREET_NUMBER
1754
Direction
E
STREET_NAME
MARIPOSA
STREET_TYPE
RD
City
STOCKTON
Zip
95205
APN
17304064
CURRENT_STATUS
01
SITE_LOCATION
1754 E MARIPOSA RD
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\M\MARIPOSA\1754\PR0514047\COMPLIANCE INFO 1989 - 2016 .PDF
QuestysFileName
COMPLIANCE INFO 1989 - 2016
QuestysRecordDate
11/28/2017 6:59:28 PM
QuestysRecordID
3735899
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
117
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Ah <br />Am <br />San Joaquin County mv <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sjaov.org/ehd <br />Small Quantity Hazardous Waste Generator Inspection Report <br />Facility Name: <br />Facility Address: <br />Date: <br />HARLEY MURRAY INC <br />1754 E MARIPOSA RD, STOCKTON <br />January 28, 2015 <br />SUMMARY OF VIOLATIONS <br />(CLASS 1, CLASS II, or MINOR - Notice to Comply) <br />Item # <br />Remarks <br />715 <br />CCR 66273.39 Failed to keep complete records of each shipment of universal waste for three years. <br />Copies of universal waste disposal records for lamps and aerosol cans were not found on site. Universal waste <br />disposal records shall be retained for three years and have them readily available for review. Immediately locate a <br />copy of all universal waste disposal receipts for the last three years, maintain them on site, and submit copies to the <br />EHD. This is a minor violation. <br />Overall Inspection Comments: <br />This is a Routine Hazardous Waste Generator inspection and Complaint (000039108) inspection. The <br />inspection was conducted in two phases, on 1/28/2015 and on 2/9/2015. <br />Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br />documenting the corrective actions that have been or will be taken for each violation, and any supporting <br />paperwork, by 3/11/2015. <br />Consent to perform the inspection, take photos and collect samples was given by Norma Palomino the General <br />Manager, and Doug Murray the owner on 1/28/2015. Raymond Robinson who will be taking over Norma's <br />position, also accompanied the inspection. The 1/28/2015 inspection was terminated at around 3pm before <br />completion as requested by Norma. A checklist only was provided to generator. Inspection resumed on <br />2/9/2015; consent to perform the inspection, take photos and collect samples was granted again by Norma <br />Palomino the General Manager and Jean Murray the Corporate Secretary. <br />Complaint alleges spent sand blasting sand were trucked out to Windmill Cove for use as beach sand and <br />volleyball courts, and hazardous waste was released to possible storm drain. <br />--Two 16 oz jar of samples were collected on 1/28/2015 and split samples were provided to generator during this <br />inspection. <br />--Facility has a General Permit to Discharge Storm Water associated with industrial activity from the State Water <br />Resources Control Board. Facility is required sampling of storm water twice a year. No signs or evidence of <br />hazardous waste or material was observed entering the storm drains, which were rounded with absorbent booms. <br />This facility generated 3.5175 tons of waste in the last calendar year (Jan -Dec) as well as the last twelve months. <br />This amount does not include the volume of contaminated water that was removed on 2/2/2015 and <br />demonstrated to EHD during 2/9/2015 inspection. Facility generates hazardous waste from its trailer <br />manufacturing operation. <br />Observed marking of Universal Waste Electronic Devices stored at the office with initial date of accumulation. <br />Please be aware that Universal Waste, including lamps, electronic devices, CRT, alkaline batteries, mercury <br />switches, aerosol cans, etc. must be stored within a closed and compatible container, marked the container to <br />identify the content within and the initial date of accumulation, stored up to a maximum of one year, and retained <br />a copy of the disposal record for minimum of 3 years on site a available for inspection. <br />Generator stated the the steam pressure washer next to the Diesel Tank is a closed-loop system, where the water <br />Received by (initial): <br />Inspector: <br />Phone: <br />Date: <br />JEFFREY WONG, Senior REHS <br />(209) 468-0335 <br />01/28/2015 <br />v Page 6 of 7 <br />
The URL can be used to link to this page