My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2008 - 2012
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HARDING
>
16
>
2300 - Underground Storage Tank Program
>
PR0231136
>
COMPLIANCE INFO 2008 - 2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/26/2024 1:28:18 PM
Creation date
11/1/2018 3:47:15 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO 2008 - 2012
FileName_PostFix
2008 - 2012
RECORD_ID
PR0231136
PE
2361
FACILITY_ID
FA0003610
FACILITY_NAME
A&A GAS & FOOD MART
STREET_NUMBER
16
Direction
E
STREET_NAME
HARDING
STREET_TYPE
WAY
City
STOCKTON
Zip
95204
APN
13902001
CURRENT_STATUS
01
SITE_LOCATION
16 E HARDING WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
279
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB, January 2002 <br />R VH.i. DlrQrl? rnrrTA IXT141`XTIV OTTAMM mr+c mr►.r <br />Page 'I of <br />-- -- vva.ia 1L'U111\lI <br />Facility is Not Equipped With fill Riser Containment Sumps <br />Fill Riser Containment Sumps are Present, but were Not Tested X <br />Test Method Developed By: ❑ Sump Manufacturer 0 Industry Standard Professional Engineer <br />❑ Other (Spec) <br />_ <br />Test Method Used: ❑ Pressure ❑ Vacuum Hydrostatic <br />❑ Other (Specify) <br />Test Equipment Used: I Equipment Resolution: <br />Fill Sump # <br />Fill Sum # <br />Fill Sump # <br />Fill Sump # <br />Sum Diameter: <br />- <br />Sump De the <br />_ - <br />- <br />Height from Tank Top to Top of <br />Hi hest Pit)inR Penetration: <br />Height from Tank Top to Lowest <br />Electrical Penetration: <br />Condition of sump prior to <br />testin : <br />- <br />Portion of Sump Tested <br />Sump Material: <br />Wait time between applying <br />water and starting test: <br />Test Start Time: <br />-- -- <br />-- <br />Initial Readin (Ri): <br />--� <br />Test End Time: <br />— <br />— — - <br />Final Reading (RF): <br />Test Duration: <br />Chane in Reading (RF-Rj): <br />Pass/Fail Threshold or Criteria: <br />-- <br />Test Result: <br />Pass Fail <br />Pass Fail <br />Pass Fail <br />Pass Fail <br />Is there a sensor in the sump? <br />Yes No <br />Yes No <br />Yes No <br />Yes No <br />Does the sensor alarm when <br />either product or water is <br />detected? <br />Yes No NA <br />Yes No NA <br />Yes No NA <br />Yes No NA <br />Was sensor removed for testing ? <br />Yes No NA <br />Yes No NA <br />Yes No NA <br />Yes No NA <br />Was sensor properly replaced and <br />verified functional after testing? <br />Yes No NA <br />Yes No NA <br />Yes No NA <br />Yes No NA <br />Comments — (include information on repairs made prior to testing, and recommended follow up or failed tests) <br />
The URL can be used to link to this page
Your browser does not support the video tag.