Laserfiche WebLink
San Joaquin County <br />Environmental Health Department <br />January 13, 2010 <br />Elite IV Contractors <br />2525 Wigwam Dr. <br />Stockton, CA 95205 <br />Fax: (209) 461-6342 <br />600 East Main Street <br />Stockton, California 95202-3029 <br />Website: www.sjgov.org/ehd <br />Phone: (209) 468-3420 <br />Fax: (209) 464-0138 <br />Re: Valley Service Station <br />16 E. Harding, Stockton, CA <br />DIRECTOR <br />Donna Heran, REHS <br />PROGRAM COORDINATORS <br />Margaret Lagorio, REHS <br />Robert McClellon, REHS <br />Jeff Carruesco, REHS, RDI <br />Kasey Foley, REHS <br />SR0058142 <br />The San Joaquin County Environmental Health Department (EHD) has completed the review of <br />the addendum to the previously approved permit SR0058142, to replace the defective sensor in <br />the 89 grade fill sump with a new Veeder-Root Model 208 sensor at the above noted address. <br />The permit addendum has been approved with the following conditions: <br />Contact the local fire department and the San Joaquin Valley Air Pollution Control <br />District for any applicable permits and requirements. <br />2. Any changes in information and scope of work must be submitted to EHD for approval <br />prior to commencing work. All new addenda supersede the previous ones. <br />3. Contact Jeff Wong at (209) 468-0335 to arrange the following inspection appointments <br />(a 48-hour notice is required for inspection appointments). Please be aware that <br />inspections for emergency work must be scheduled within five days of permit approval. <br />a. Sensor functionality: Functionality of the monitoring system must be verified to <br />ensure that monitoring has been restored to meet the requirements of Title 23 <br />California Code of Regulations and the Health & Safety Code. (The replacement <br />was performed as an emergency repair on January 11, 2010 during the annual <br />monitoring certification. Verification of its functionality had been performed under <br />inspection on January 11, 2010) <br />Please be aware that the facility cannot operate the UST system prior to the EHD <br />inspection and approval. <br />4. If concrete will be broken near the UST or piping, a secondary containment test must be <br />performed on the UST or piping once concrete is poured in accordance with the <br />manufacturer's guidelines. <br />5. Qualified service technicians must possess or work under the direct and personal <br />supervision of an individual physically present at the work site who possesses all of the <br />following: <br />