My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2013 - 2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HARDING
>
16
>
2300 - Underground Storage Tank Program
>
PR0231136
>
COMPLIANCE INFO_2013 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/18/2023 1:43:23 PM
Creation date
11/1/2018 4:00:53 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013 - 2018
RECORD_ID
PR0231136
PE
2361
FACILITY_ID
FA0003610
FACILITY_NAME
A&A GAS & FOOD MART
STREET_NUMBER
16
Direction
E
STREET_NAME
HARDING
STREET_TYPE
WAY
City
STOCKTON
Zip
95204
APN
13902001
CURRENT_STATUS
01
SITE_LOCATION
16 E HARDING WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
291
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
e(for any purpose)at any or ,hazardous materials at or above 55 gallons for liquids,500 pounri-'relmenor 200 Yes I <br /> ic reeulated under more restrictive inventory local reportin <br /> -o-d In 40 CFR 1 5,Appendix <br /> San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue,Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.siaov.ora/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> A&A GAS&FOOD MART 16 E HARDING WAY STOCKTON February 28 2018 <br /> UST System Observations <br /> 318 CCR 2636(0(2) Leak detector failed to detect a 3.0 gph leak at 10 psi o V in R o COS <br /> 319 CCR 2635(b) No spill bucket,failed to contain five gallons,or failed to provide a means to keep it empty o V o R o COS <br /> 320 CCR 2635(b)(2) Overfill prevention system not present or failed to meet overfill requirements o V o R o COS <br /> 321 CCR 2635(b)(2) Overfill prevention was overridden o V o R o COS <br /> 322 HSC 25281.6(a) Unburied below grade emergency generator system failed to meet exemption status o V o R o COS <br /> 323 HSC 25283.5(a) Unburied below grade UST system failed to meet exemption status o V o R o COS <br /> 324 CCR 2717.1(g) Tampered with red tag o V o R o COS <br /> 325 CCR 2717.1(() Deposited petroleum into a red tagged UST o V o R o COS <br /> 326 HSC 25299(a)(9) Tampered with or disabled leak detection devices or alarms o V o R o COS <br /> 327 CCR 2631.1 UST system not compatible with the substance stored o V c R o COS <br /> 328 HSC 25298 Failed to comply with temporary closure requirements o V c R o COS <br /> 329 HSC 25298 Failed to comply with all permanent closure requirements o V o R o COS <br /> 330 CCR 2636(f)(6) Failure to meet all requirements in lieu of a line leak detector for emergency generator tank system o V o R o COS <br /> 331 CCR 2630(d) Secondarily contained piping not maintained to allow liquid to drain into sump o V o R o COS <br /> 332 CCR 2631(b),2631(d) Primary and/or secondary containment not constructed in accordance with the established standards o V o R o COS <br /> w <br /> in' Iled'Nan=F'rest;u <br /> 401 CCR 2636(a)(3) Suction piping not properly sloped or incorrectly located check valve I.V o R o COS <br /> 402 CCR 2643(d) Daily monitoring of suction pipe(pre-Jan 1984)not performed o V o R c COS <br /> 403 CCR 2643(d) Triennial 0.1 gph line test for conventional suction piping not performed(pre-January 1984) o V o R o COS <br /> 404 CCR 2643(e) Biennial 0.1 gph test for gravity piping not performed(pre-January 1984) o V o R o COS <br /> Other Violations <br /> 2010 See below Unlisted General violation ❑V ❑R ❑COS <br /> SUMMARY OF VIOLATIONS <br /> I.CLAS311,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 103 HSC 25292.2,25299.30 Current financial responsibility documents not submitted. <br /> Financial responsibility documents have not been submitted to the EHD. On the Certification of Financial <br /> Responsibility, Section C does not include annual aggregate amounts. Current financial responsibility documents are <br /> required to be submitted annually. Immediately log into the California Environmental Reporting System (CERS)at r <br /> http://cers.calepa.ca.gov/, and upload the requUed documents. Awyl �N S Q <br /> SA <br /> This is a minor violatio9. <br /> tie --3 /1 r c, �� 1�j ln�G� (f ,.51cell J-D <br /> FAD003610 PR0231136 SCO01 02/28/2018 <br /> EHD 23-01 Rev.0922116 Page 3 of 6 Underground Storage Tank Program OIR <br />
The URL can be used to link to this page
Your browser does not support the video tag.