My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2001-2012
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CALIFORNIA
>
1405
>
2300 - Underground Storage Tank Program
>
PR0231485
>
COMPLIANCE INFO 2001-2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/27/2022 11:44:39 AM
Creation date
11/2/2018 3:45:20 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2001-2012
RECORD_ID
PR0231485
PE
2361
FACILITY_ID
FA0000306
FACILITY_NAME
EMILS LIQUOR & SPORTS SHOP*
STREET_NUMBER
1405
STREET_NAME
CALIFORNIA
STREET_TYPE
ST
City
ESCALON
Zip
95320
APN
22707031
CURRENT_STATUS
01
SITE_LOCATION
1405 CALIFORNIA ST
P_LOCATION
06
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\C\CALIFORNIA\1405\PR0231485\COMPLIANCE INFO 2001-2012.PDF
QuestysFileName
COMPLIANCE INFO 2001-2012
QuestysRecordDate
5/14/2018 3:33:43 PM
QuestysRecordID
3891081
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
359
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
S W KCB,January 2002 Page of <br /> 6. PIPING SUMP TESTING <br /> Test Method Developed By: D Sump Manufacturer KIndustry Standard C Professional Engineer <br /> 0 Other(Spec) <br /> Test Method Used: D Pressure 0 Vacuum of Hydrostatic <br /> D Other(Spec) <br /> Test Equipment Used: INCON Equipment Resolution: .0001" <br /> Sump#87 1 Sump 9 91 Sump#DSL Sump# <br /> Sump Diameter: 32 32 32 <br /> Sump Depth: 59 59 60 <br /> Sump Material: Fiberglass Fiberglass Fiberglass <br /> Height from Tank Top to Top of 15 15 15 <br /> Hi hest Piping Penetration: <br /> Height from Tank Top to Lowest 17 17 17 <br /> Electrical Penetration: <br /> Condition of sump prior to testing: Good Good Good <br /> Portion of Sump Tested' 17 17 17 <br /> Does turbine shut down when <br /> sump sensor detects liquid(both td Yes 0 No0 NA N Yes CNo CNA ,4 Yes 0 No DNA D Yes D No DNA <br /> product and water)?* <br /> Turbine shutdown response time 5 sec 5 sec 5 see <br /> Is system programmed for fail-safe Yes D No C NA A Yes C No 0 NA I4 Yes C No 0 NA []Yes D No CNA <br /> shutdown?* <br /> Was <br /> saeverified tobe Yes CNo DNA A.Yes ONo CNA JRYes CNo DNA ❑Yes 0 N CNA <br /> operational?* <br /> Wait time between applying <br /> pressure/vacuum/water and starting <br /> test: <br /> Test Start Time: 1123 1202 1237 <br /> Initial Reading(Rj): 3.5486 3.2437 2.6975 <br /> Test End Time: 1138 1217 1253 <br /> Final Reading(RF): 3.5481 3.2425 2.6966 <br /> Test Duration: 15 min 15 min 15 min <br /> Change in Reading(RF-Ri): .0001 .0012 .0009 <br /> Pass/Fail Threshold or Criteria: .002 .002 .002 <br /> Test Result: 4 Pass 0 Fail 9 Pass 0 Fail q Pass ❑Fail 0 Pass D Fail <br /> Was sensor removed for testing? kl Yes D No DNA fa Yes D No DNA KYes 0 No DNA D Yes 0 No [INA <br /> Was sensor properly replaced and Ctyes CNo DNA $Yes CNo DNA W Yes C No D NA C Yes D No ❑NA <br /> verified functional after testin . <br /> Comments—(include information on repairs made prior to testing, and recommended follow-up forfailed tests) <br /> If the entire depth of the sump is not tested,specify how much was tested. if the answer to any of the questions indicated with an <br /> asterisk(*)is"NO"or"NA",the entire sump must be tested. (See SWRCB LG-160) <br />
The URL can be used to link to this page
Your browser does not support the video tag.