Laserfiche WebLink
A B C " D E F y. <br /> 76 PRODUCTS MONITORING SYSTEM STANDARD <br /> FOR VARIOUS TANK AND PIPING CONFIGURATIONS <br /> VEEDER ROOT SYSTEMS <br /> 1 A (') B C D(') E F G H I J 76CFS <br /> 2-GASOLINE 2-GASOLINE 2-GASOUNE 2-GASOLINE 2-GASOUNE 2-GASOUNE - 2 GASOLINE 2-GASOUNE 2-GASO4INE 2-GASOLINE -GASOLINE -DIES <br /> 1-DIES L i-DIESEL 1-DIESEL 1-W 0 TANK 1 DIESEL PIPINGC, D/W PIPING 1-DIESEL 1-WASTEWATER <br /> S/W PIING Day PIPING S PIPING $ PIPING D PIPING D PIPING Wr, PIPING SABEIR SS D/W FRP TANK D/W PIPING p W PIPING <br /> DESCRIPTION PART NO. S/W STEEL TANK D/W STEEL TANK D/W STEEL TANK $/W STEEL TANK D STEEL TANK D/ TEFL TANK S/W FIBERGLASS D/W FRP TANK D/W STEETANK <br /> (QTY) (QTY) (QTY) (QTY) (QTY) (aTy) (QTY) (CITY) (OM (QTY) (QTY y <br /> TLS-350 CONSOLE WITH PRINTER 847080-022 0 1 0 0 1 1 1 1 1 1 0 ? <br /> TLS-350R CONSOLE WITH PRINTER 848290-122 0 0 0 0 0 0 0 0 0 0 1 <br /> TLS-350R CONSOLE WITH PRINTER WITHOUT BIR 848290-022 1 0 1 1 0 0 0 0 0 <br /> RS-232 INTERFACE MODULE 329362-001 1 1 1 1 1 i 1 1 i <br /> DISPENSER INTERFACE MODULE 330280-201 0 0 0 0 0 0 <br /> CSLD SOFTWARE ASSUMES 24 HR SITE 330160-002 1 0 0 1 0 0 1 1 1 1 0 <br /> OVERFILL ALARM 790091-001 0 0 0 0 0 0 0 0 0 0 1 s <br /> ALARM ACKNOWLEGMENT SWITCH 790095-001 0 0 p 0 0 0 0 0 0 0 <br /> 8-INPUT INTERSTITIAL MODULE 847490-102 1 1 1 1 1 1 1 1 1 1 1 2 <br /> SUMP SENSOR 794380-208 3 3 3 2 3 2 3 2 2 2 12 <br /> INTERSTITIAL SENSOR-10' FRP TANK 794390-409 0 3 3 0 0 0 0 0 2 3 3 <br /> INTERSTITIAL SENSOR-4' FRP TANK 794390-401 0 3 3 0 3 2 0 0 0 0 1 ) <br /> INTERSTITIAL SENSOR-STEEL 794390-420 0 3 3 0 3 2 0 0 <br /> 4-INPUT PROBE MODULE 847490-104 1 1 1 1 1 1 1 1 1 1 1 <br /> 10 FOOT MAG 1 IN-TANK PROBE TANK GAUGING 847390-109 0 3 3 0 2 2 0 0 2 3 <br /> 8 FOOT MAG 1 IN-TANK PROBE TANK GAUGING 847390-107 0 0 2 0 0 3 2 0 0 0 <br /> 6 FOOT MAG 1 IN-TANK PROBE TANK GAUGING 847390-104 0 0 0 0 0 0 0 1 0 0 0 1 <br /> MAG PROBE INSTALL KIT-GASOLINE 849600-000 2 2 2 2 2 2 2 2 2 2 3 <br /> MAG PROBE INSTALL KIT-DIESEL 849600-001 1 1 1 0 0 0 1 0 <br /> PROBE CAP AND RING KIT 312020-952 3 3 3 2 2 2 3 2 2 2 4 <br /> 1 -INPUT LINE LEAK MODULE 329398-001 3 0 3 2 0 0 0 0 0 0 0y <br /> LINE LEAK DETECTOR KIT LINE PRESSURE SENSOR 847590-001 3 0 3 2 0 0 0 0 0 0 0 <br /> 4-RELAY OUTPUT MODULE 847490-200 0 1 0 0 1 1 1 i 1 1 1 <br /> EXPANSION MODULE 847490-001 1 0 1 1 0 0 1 1 1 1 1 1 1 <br /> 2 INTERSTITIAL CAP AND ADAPTER 312020-928 03 3 0 3 2 0 0 0 0 0 <br /> THERMISTOR FOR LINE LEAK DETECTION 576010-856 1 0 1 1 0 0 1 0 1 0 0 0 0 }' <br /> fi <br /> OPTIONS 2 ON VEEDER ROOT SYSTEMS I A- 1 1 . B- 1 C- 1 D- 1 1 E- 1 I F- 1 I G- 1 I H- 1 1- 1 <br /> SUMP SENSOR 794390-208 3 3 3 2 2 2 3 2 2 <br /> 8-INPUT INTERSTITIAL MODULE 847490-102 1 0 11 1 01 0 0 0 1 0 0 <br /> NOTES <br /> (1) INSTALLATION OF VEEDER ROOT EQUIPMENT WITH SYSTEMS 'A' OR 'D' UNDERGROUND EQUIPMENT REQUIRES REGIONAL ENGINEERING MANAGER APPROVAL. <br /> (2) OPTIONS ARE FOR WHEN ENVIRONMENTAL AGENCY REQUIRES BOTH FILLS AND TURBINE SUMPS TO BE MONITORED. <br /> (3) LENGTH OF THE TANK PROBE WILL VARY DEPENDING ON THE DIAMETER OF THE TANK. A 10 FOOT PROBE IS SPECIFIED IN THE TABLE FOR THE NEW <br /> 9.5 FOOT DIAMETER TANKS. ' <br /> VEEDER -ROOT TLS-350 SETUP AND CONFIGURATION REQUIREMENTS FOR III IN-TANK SETUP DATA (UNOCAL STATION TYPES A B C D E F,G H) IV. IN TANK AUTO LEAK TEST SETUP DATA single wall tanks only) VII, OUTPUT RELAY SETUP <br /> ALL UNOCAL STATIONS. STATION TYPES A,D,G.H <br /> The following guidelines will be used at all Unocal Veeder-Root TLS-350 system Follow the normal setup procedures. Use the following information as a standard. ) (Double walled piping and/or tanks.) <br /> (UNOCAL STATION TYPES B.C,E,F.G H) <br /> locations as shown in the above table. Standard setup values such as thermal A. Leak Test Method... All tanks <br /> coefficients and other site specific parameters will not be covered in this document. A.) Water Warning... Gasoline-1 .5° Diesel/Rocing Fuel-1 .0 B.) Leak Test Frequency... CSLD (0.2GPH Testing) t <br /> Refer to Veeder-Root System Setup. p B This alarm Alarm... <br /> assignedlinto 0P Diesel/Racing <br /> ies I/Raacin�shut <br /> wIf the station is p not operating 24 hours then the in-tank A, Relay Type... Standard <br /> Manual Number 576013-880 for complete setupInstructions. o p testingwill be programmed for when the station is closed. y yp <br /> C. Maximum or Label Limit... Total tank capacity as per the tank chart. B. Relay Orlentaion.,, Normally Closed <br /> ONLY AUTHORIZED VEEDER-ROOT CONTRACTORS MAY PERFORM SYSTEM SETUP PROCEDURES D. Overfill Limit` Alarm... 90% V. PRESSURIZED AND VOLUMETRIC LINE LEAK SETUP (Single wall lines oC. Assignment Method. <br /> E. High Level Limit Alarm... 95% (STATION TYPES A,C.D) In-Tank Alarms. (All Tanks) <br /> F. Delivery Limit Warning.., 20% (This may also be a dealer's option.) A.) 0. 1 GPH Test... Enabled (Pressure LLD requires this test to be 1 .) Periodic Test Alarm <br /> 3 1. SYSTEM SETUP (UNOCAL STATION TYPES A,B,C D,E,F,G.H) G. Low Level Limit Alarm... Use the gallon amount of a 10' level from off the enabled in order to run a 0.10 GPH test. Volumetric LLD is already 2• High Water Alarm <br /> A.) Station Header....Must include xxxx digit Unocal site number along tank chart. This alarm will be assigned to perform line shut down. programed for the 0.10 GPH automatically.) <br /> 3. Low Level Limit <br /> Limit <br /> Li <br /> Leak Alarm arm m <br /> with address. H.) Leak Alarm Limit (During In-tank testing ... 50 gallons, B.) Shutdown Rate... 3.0 GPH only. This -alarm will cause line shut 4. 9 <br /> This alarm will be assi ned to erform line shut down. down upon 3.OGPH testing failure. 5. Sudden loss Limit <br /> B.) Shift Start Times....This option will be up to the dealer. Otherwise, p E p g <br /> shift time #1 will be set at 6:00 a.m. (Shift times 2,3&4 will not I.) Sudden Loss Limit (During In-tank quite time)... 50 gallons. C.) Pumpside Test (VLLD)... Enabled only if containment is NOT 4 Liquid Sensor Alarms, (All Sensors) <br /> be utilized.) This alarm will be assigned to perform line shut down. being monitored with a sump sensor. 1 .) Fuel Alarms. <br /> C.) Periodic 0.2GPH Test Warnings... Enabled (Days=25). Single wall tanks J.) Tank Tilt... If probe is mounted in the center of the tank, then the tank tilt D.) Wait Mode... Temp. Meas. (If the system has a thermistor installed.) <br /> only will be set at default 0.00. If the probe is not centered in the middle of the Vol. Change (If the system doesn't have a thermistor installed.) <br /> D.) Periodic 0.2GPH Test Alarms... Enabled (Days=28). tank, then follow the instructions in Section 8.D.3 of the Setup Manual for E.) NBP Partner... Enabled (This is required if the station has mechanical <br /> Single wall tanks only. This alarm will be assigned to perform line shut down. calculating tank tilt. DO NOT USE TANK TILT TO MATCH THE MANUAL blenders or if the station has single wall lines.) Y; <br /> Annual 0. 1 GPH Test Warnings... Enabled (Days=340). Single wall tanks only. STICK READING. IN MOST CASES THE TLS-350 SHOULD NOT MATCH THE STICK. <br /> E.F.� Annual 0. 1 GHP Test Alarms... Enabled (Days=360). Single wall tanks only. K.) Leak Minimum 0. 1 GPH Annual... 10% (Set as per tocol regulatory codes.) VI. OUTPUT RELAY SETUP (ALL SYSTEMS EQUIPPED WITHOUT LINE LEAK <br /> This alarm will be assigned to perform line shut down. L.) Periodic 0.2GPH Test Type... Standard DETECTION-UNOCAL STATION TYPES B,E.F,G.H) <br /> G.) System Security Code... Enabled - The six digit number will be at the M. Annual O, 1GPH Test Fail... Disabled <br /> choosing of the programming contactor. N. Periodic 0.2GPH Test Fail... Disabled A.) Relay Type.:, Standard <br /> 0. Gross 3.OGPH Test Fail... Enabled B. Relay Orientaion... Normally Open <br /> P. Annual 0.10PH Test Averaging... Off C. Assignment Method. <br /> II. COMMUNICATION SETUP DATA UNOCAL STATION TYPES A,B.C,D,E,F,G,H) In-Tank Alarms. All Tanks <br /> ( Q. Periodic 0.2GPH Test Averaging... Off 1 . Periodic Test Alarms) l <br /> R. Tank Test Notify... On <br /> Do not change from system defaults unless .site has communication capalbility. S. Tank Test Siphon Break... Off (Turn ON if tanks are manifolded and a V/R siphon 2. High Water Alarms <br /> break valve is installed.) 3. Low Level Limit <br /> T.) Delivery Report Delay... 2 minutes. Lig4Iii <br /> s <br /> L�e+f'�I' <br /> dldairrlt �ll Sensors) <br /> �: � arlr��s I I <br /> REV DATE REVISED BFPR�YELL RD DO "'RP° APPROVALS -- ----- <br /> BY' APPROVAL RECORp , I <br /> 4 © UNION OIL OF CALIFORNIA, dba UNOCAL, 1994 MILESTONE LDAIIE,; APPROVAL �^ � RH VEEDER ROOT SYSTEM <br /> THIS DOCUMENT AND THE INFORMATION CONTAINED HEREIN IS ISSUED FOR C.U.P. UNDERGROUND STORAGE TANK STANDARD I <br /> CAECKEP BYPROPRIETARY TO UNION OIL OF CALIFORNIA (UNOCAL) AND HASBEEN FURNISHED IN CONFIDENCE AND ARE SUBJECT TO THE ISSUED FGR Plan CHECK <br /> TERMS OF A SEPARATE SECRECY AGREEMENT BETWEEN UNOCAL ADMDAND THE RECIPIENT. THE RECIPIENT IS NOT TO COPY, DUPLICATE - ISSUED FGR GEN. BID --- -- -- ------ - ---- <br /> OR DISCLOSE THE CONTENTS TO ANY PERSON OR ENTITY EXCEPT DATE 410 96 NO SN B L` DATE DRAM"° NO REv U <br /> AS EXPRESSLY AUTHORIZED BY SAID 'AGREEMENT OR BY UNOCAL - <br /> SSUED FOR GGN$TRUGT. PRODUCTS COYPAHI' - o, 5 n <br /> IN WRITING. - C E NONE <br /> pr vtrr; <br /> _ - RECORD DRAWING (wNsmucTipv ENLiNfIR} Tr <br /> A B G D E F <br /> _. - <br />