Laserfiche WebLink
_ UNIFIED PROGRAM CONSOLIDATED FW <br /> %sa UNDERGROUND STORAGE TANK <br /> MONITORING PLAN- Pee l oft <br /> TYPE OF ACTION ❑ 1.NEW PLAN ® 2.CHANGE OF INFORMATION 00'' <br /> PLAN TYPE ® 1.MONITORING IS IDENTICAL FOR ALL USTs AT THIS FACILITY. 6 2 <br /> (Check one item only) ❑ 2.THIS PLAN COVERS ONLY THE FOLLOWING UST SYSTEM(S)- <br /> L FACILITY INFORMATION <br /> FACILITY ID#(Agency Use Only) I I1 <br /> BUSINESS NAME(Same as FACILITY NAME)Vanoo Truck&Amo Plaza 3. <br /> BUSINESS SITE ADDRESS 1033 W Charter Way 103' CITY Stockton CA 95206 IN. <br /> IL EQUIPMENT TESTING AND PREVENTIVE MAINTENANCE <br /> Testing,preventive maintenance,and calibration of monitoring equipment(e.g.,sensors,probes,line leek detect Insist be <br /> speed by the equipment mamlfacturers'instructions,or annually,whichever is more frequent,and that such work must)be performed <br /> byyqualified <br /> at the frequency <br /> 23 CCR§2632,2634,2638,2641) P ualified personnel. <br /> MONITORING EQUIPMENT IS SERVICED ® 1.ANNUALLY ❑ 99.OTHER(Specify): 490-3e <br /> 49a3b <br /> M.MONITORING LOCATIONS <br /> I.NEW SITE PLOT PLAN/MAP SUBMITTED WITH THIS PLAN. 0 2.SITE PLOT PLANIMAP PREVIOUSLY SUBMITTED. (23 CCR 12632, <br /> 2634 <br /> IV. TANK MONITORING IS PERFORMED USING THE FOLLOWING METHOD(S): <br /> 99 1.CONTINUOUS ELECTRONIC TANK MONITORING OF ANNULAR(INTERSTITIAL)SPACE(S)OR SECONDARY CONTAINMENT 4905 <br /> VAULT(S)WITH AUDIBLE AND VISUAL ALARMS. (23 CCR§2632,2634) <br /> SECONDARY CONTAINMENT IS: ® a.DRY ❑ b.LIQUID FILLED E c.PRESSURIZED ❑d.UNDER VACUUM 4906 <br /> PANEL MANUFACTURER: Veeder Root 490"5 MODEL#: TLS 350 090$ <br /> LEAK SENSOR MANUFACTURER: Veeder Root 490-9. MODEL#(S): 409 490-10 <br /> 2.AUTOMATIC TANK GAUGING(ATG)SYSTEM USED TO MONITOR SINGLE WALL TANK(n(23 CCR 12643) 49x11 <br /> PANEL MANUFACTURER: 49042. MODEL#: 49 13 <br /> IN-TANK PROBE MANUFACTURER: 49044. MODEL#(S): 490-15 <br /> LEAK TEST FREQUENCY: ❑ a.CONTINUOUS ❑ b.DAILYNIGHTLY ❑ c.WEEKLY M-16 <br /> __❑ d.MONTHLY ❑ e.OTHER(Specify): 49x17 <br /> PROGRAMMED TESTS: ❑ a.0.1 g.p.h. ❑ b.0.2 g.p.h. ❑ c.OTHER(Specify): 490 8 <br /> ❑ 3.MONTHLY STATISTICAL INVENTORY RECONCILIATION(23 CCR 12646.1): 490-20 <br /> ❑ 4.WEEKLY MANUAL TANK GAUGING(MTG)(23 CCR 12609. TESTING PERIOD: ❑ a 36 HOURS ❑ b.60 HOURS d90-31 <br /> 490-22 <br /> 5.TANK INTEGRITY TESTING(23 CCR 12643.1): 490-23 <br /> TEST FREQUENCY: ❑ a.ANNUALLY ❑ b.BIENNIALLY ❑ c.OTHER(Specify): 49 24 <br /> 490-25 <br /> ❑99.OTHER (Specify): 490_26 <br /> 490-n <br /> V.PIPE MONITORING IS PERFORMED USING THE FOLLOWING METHOD(S)(Check all that apply) <br /> I.CONTINUOUS MONITORING OF PIPE/PIPING SUMP(S)AND OTHER SECONDARY CONTAINMENT WITH AUDIBLE AND 49o_28 <br /> VISUAL ALARMS. (23 CCR 12636) <br /> SECONDARY CONTAINMENT IS:®a.DRY ❑b.LIQUID FILLED ®c.PRESSURIZED ❑&UNDER VACUUM 490-29 <br /> PANEL MANUFACTURER:Veeder Root 490'30 1 MODEL#: TLS 350 490x1 <br /> LEAK SENSOR MANUFACTURER: Veeder Root 490-32 1 MODEL#(S): 208 490x3 <br /> PIPING LEAK ALARM TRIGGERS AUTOMATIC PUMP(i.e.,TURBINE)SHUTDOWN. ®a.YES ❑b.NO 490-34 <br /> FAILURE/DISCONNECTION OF THE MONITORING SYSTEM TRIGGERS AUTOMATIC PUMP SHUTDOWN. ®a.YES ❑b.NO 490-35 <br /> 2.MECHANICAL LINE LEAK DETECTOR(MILLD)THAT ROUTINELY PERFORMS 3.0 g.p.h.LEAK TESTS AND RESTRICTS OR SHUTS OFF <br /> PRODUCT FLOW WHEN A LEAK IS DETECTED CCR 263 _ 4WM <br /> MUD MANUFACTURERM:VMI, Red Jaket 490-37 MODEL#(S): LD3000,99LD2000,FX IV 49o-3s <br /> ❑ 3.ELECTRONIC LINE LEAK DETECTOR(ELLD)THAT ROUTINELY PERFORMS 3.0 g.p.h.LEAK TESTS (23 CCR 12636) 490.39 <br /> ELLD MANUFACTURER(S) 490-401 MODEL#(S): 490'41 <br /> PROGRAMMED IN LINE LEAK TEST: ❑ 1.MINIMUM MONTHLY 0.2&p.h. ❑ 2.MINIMUM ANNUAL 0.1 g.p.h. 49042 <br /> ELLD DETECTION OF A PIPING LEAK TRIGGERS AUTOMATIC PUMP SHUTDOWN. ❑a.YES ❑b.NO 49043 <br /> ELLD FAILURE/DISCONNECTION TRIGGERS AUTOMATIC PUMP SHUTDOWN. ❑ a.YES ❑b.NO 49a4a <br /> 4.PIPE INTEGRITY TESTING 490x5 <br /> TEST FREQUENCY ❑ a.ANNUALLY ❑ b.EVERY 3 YEARS ❑ c.OTHER (Spec' 490-46490-47 <br /> 5.VISUAL PIPE MONITORING. d� <br /> FREQUENCY ❑ a.DAILY ❑ b.WEEKLY ❑a MIN MONTHLY&EACH TR fE SYSTEM OPERATED- 4049 <br /> •Nbwea ae menti ofmbmu em ten fuel HSC 25281.5@ 3 <br /> ❑ 6.SUCTION PIPING MEETS EXEMPTION CRITERIA 123 CCR 12636(a)(3)1• 490-50 <br /> 7.NO REGULATED PIPING PER HEALTH AND SAFETY CODE,DIVISION 20,CHAPTER 6.7 IS CONNECTED TO THE TANK SYSTEM <br /> 60-51 <br /> ❑ 99.OTHER(Specify) 6o-s2 <br /> 60-53 <br />