My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2016 - 2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CHARTER
>
1033
>
2300 - Underground Storage Tank Program
>
PR0232352
>
COMPLIANCE INFO_2016 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/26/2022 2:10:29 PM
Creation date
11/2/2018 4:33:55 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016 - 2018
RECORD_ID
PR0232352
PE
2361
FACILITY_ID
FA0003829
FACILITY_NAME
VANCO TRUCK-AUTO PLAZA
STREET_NUMBER
1033
Direction
W
STREET_NAME
CHARTER
STREET_TYPE
WAY
City
STOCKTON
Zip
95206
APN
16323041
CURRENT_STATUS
01
SITE_LOCATION
1033 W CHARTER WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\C\CHARTER\1033\PR0232352\COMPLIANCE INFO 2016 - 2017.PDF
QuestysFileName
COMPLIANCE INFO 2016 - 2017
QuestysRecordDate
8/8/2018 11:06:32 PM
QuestysRecordID
3201703
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
330
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
HtL;t:1 V crr <br /> SEP 2 S 2016 <br /> 9. TANK ANNULAR TESTING HPALTH <br /> Test Method Developed By: ❑Tank Manufacturer ®Industry Standardro ef�I° '$IOfE?!`1T <br /> [I Other(Spec) <br /> Test Method Used: ❑Pressure ®Vacuum ❑Hydrostatic <br /> ❑Other(Spec) <br /> Test Equipment Used:VACUUM GAUGE Equipment Resolution:OS" <br /> Tank#DSL 2 Tank# Tank# Tank# <br /> Is Tank Exempt From Testing?' ❑Yes ®No ❑Yes ❑No ❑Yes ❑No ❑Yes ❑No <br /> Tank Capacity: <br /> Tank Material: FG <br /> Tank Manufacturer: UNKNOWN <br /> Product Stored: DSL <br /> Wait time between applying <br /> pressure/vacuum/water and 5 MIN <br /> starting test: <br /> Test Start Time: 11:30 <br /> Initial Reading(Rd: -10" " <br /> Test End Time: 12:30 <br /> Final Reading(RF): -10" <br /> Test Duration: IHR 1 HR IRR 1 HR <br /> Change in Reading(RF-Rr): 0 <br /> Pass/Fail Threshold or Criteria: 0 0 0 0 <br /> Test Result: ®Pass Fail ❑Pass ❑Fail ❑Pass ❑Fail ❑Pass ❑FaU` <br /> Was sensor removed for testing? .. ®YeEEIZEI NA ❑Yes❑No❑NA ❑Yes❑No❑NA ❑Yes❑No❑NA <br /> Was sensor properly replaced and ®ye ❑NA El Yes❑No❑NA ❑Yes❑No❑NA ❑Yes❑No❑NA <br /> verified functional after testing? <br /> Comments— (include information on repairs made prior to testing and recommended follow-upjor failed tests) <br /> 10. <br /> ' Secondary containment systems where the continuous monitoring automatically monitors both the primary and secondary <br /> containment,such as systems that are hydrostatically monitored or under constant vacuum,are exempt from periodic containment <br /> testing. {Cal ifomia Code of Regulations,Title 23,Section 2637(a)(6)) <br /> Secondary Containment Test Results 4 of 15 <br />
The URL can be used to link to this page
Your browser does not support the video tag.