My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2016 - 2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CHARTER
>
1033
>
2300 - Underground Storage Tank Program
>
PR0232352
>
COMPLIANCE INFO_2016 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/26/2022 2:10:29 PM
Creation date
11/2/2018 4:33:55 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016 - 2018
RECORD_ID
PR0232352
PE
2361
FACILITY_ID
FA0003829
FACILITY_NAME
VANCO TRUCK-AUTO PLAZA
STREET_NUMBER
1033
Direction
W
STREET_NAME
CHARTER
STREET_TYPE
WAY
City
STOCKTON
Zip
95206
APN
16323041
CURRENT_STATUS
01
SITE_LOCATION
1033 W CHARTER WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\C\CHARTER\1033\PR0232352\COMPLIANCE INFO 2016 - 2017.PDF
QuestysFileName
COMPLIANCE INFO 2016 - 2017
QuestysRecordDate
8/8/2018 11:06:32 PM
QuestysRecordID
3201703
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
330
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
_ JRECEIE® <br /> SEP 2 8 2016 <br /> PIPING SUMP TESTING H <br /> Test Method Developed By: ❑ Sump Manufacturer ®Industry Standard EM('� <br /> ❑Other(Specify) DEPARTMENT <br /> Test Method Used: ❑Pressure ❑vacuum ®Hydrostatic <br /> ❑Other(Specify) <br /> k <br /> Equipment Used: INCON TS-STS Equipment Resolution:0.0001 <br /> Sump#OCT. 100 Sump#91 Sump#87 Sump#DSL I <br /> Sump Diameter: 36" 36" 36" 36" <br /> Sump Depth: 65" 63" 63" <br /> Sump Material: FG FG FG FG <br /> Height from Tank Top to Top of 21" 20" 22" 22" <br /> Highest Pipin Penetration: <br /> Height from Tank Top to Lowest35" 34" 19" 18" <br /> Electrical Penetration: <br /> Condition of sump prior to testing: FAIR FAIR FAIR FAIR <br /> Portion of Sump Tested' 40" 41" 40" 40" <br /> Does turbine shut down when <br /> sump sensor detects liquid(both ®Yes❑No❑NA ®Yes❑No❑NA ®Yes❑No❑NA ®Yes❑No❑NA <br /> product and water)?* <br /> Turbine shutdown response time 6 SEC 6 SEC 6 SEC 6 SEC <br /> Is system programmed for fail-safe ®Yes❑No❑NA ®Yes❑No❑NA ®Yes❑No❑NA ®Yes❑No❑NA <br /> shutdown?' <br /> Was fail-safe verified to be ®Yes❑No❑NA ®Yes❑No❑NA ®Yes❑No❑NA ®Yes❑No❑NA <br /> o rational7' <br /> Wait time between applying <br /> pressure/vacuum/water and starting 15 MIN 15 MIN 15 MIN 15 MIN <br /> test: <br /> Test Start Time: 10:52 10:52 12:18 12:57 <br /> Initial Reading(Ri): 21979 47636 10942 15108 <br /> Test End Time: 11:07 11:07 12:34 1:13 <br /> Final Reading(RF): 21987 47638 10947 15107 <br /> Test Duration: 15 MIN 15 MIN 15 MIN 15 MIN <br /> Change in Reading(RF-Ri): 0.0008 0.0002 0.0005 0.0001 <br /> Pass/Fail Threshold or Criteria: 0.002 0.002 0.002 0.002 <br /> 'Test Result: ®Pass ❑Fa0- ®Pass ❑Fail ®SSS ❑Fail ®Pass OVA <br /> Was sensor removed for testing? ®Yes❑No❑NA ®Yes❑No❑NA ®Yes❑No❑NA ®Yes❑No❑NA <br /> Was sensor properly replaced and O Yes❑No❑NA ®Yes❑No❑NA ®Yes❑No❑NA ®Yes❑No❑NA <br /> verified functional after testin ? <br /> Comments— (include information on repairs made prior to testing, and recommendedfollow-up for failed tests) <br /> ' If the entire depth of the sump is not tested,specify how much was tested. If the answer to any of the questions indicated with an <br /> asterisk(*)is"NO"or"NA",the entire sump must be tested. (See S WRCB LG-160) <br /> Secondary Containment Test Results 8 of 15 <br />
The URL can be used to link to this page
Your browser does not support the video tag.