My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2016 - 2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CHARTER
>
1033
>
2300 - Underground Storage Tank Program
>
PR0232352
>
COMPLIANCE INFO_2016 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/26/2022 2:10:29 PM
Creation date
11/2/2018 4:33:55 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016 - 2018
RECORD_ID
PR0232352
PE
2361
FACILITY_ID
FA0003829
FACILITY_NAME
VANCO TRUCK-AUTO PLAZA
STREET_NUMBER
1033
Direction
W
STREET_NAME
CHARTER
STREET_TYPE
WAY
City
STOCKTON
Zip
95206
APN
16323041
CURRENT_STATUS
01
SITE_LOCATION
1033 W CHARTER WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\C\CHARTER\1033\PR0232352\COMPLIANCE INFO 2016 - 2017.PDF
QuestysFileName
COMPLIANCE INFO 2016 - 2017
QuestysRecordDate
8/8/2018 11:06:32 PM
QuestysRecordID
3201703
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
330
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
v <br /> SEP 2 8 2016 <br /> ENVIRONMENTAL HEALTH <br /> DEPARTMENT <br /> PIPING SUMP TESTING <br /> Test Method Developed By: ❑ Sump Manufacturer ®Industry Standard ❑ Professional Engineer <br /> ❑Other(Spec) <br /> Test Method Used: ❑Pressure ❑Vacuum ®Hydrostatic <br /> ❑Other(Specify) <br /> Test Equipment Used:INCON TS-STS Equipment Resolution:0.0001 <br /> Sump#DSL 2 Sump#DSL 2 Sump# Sump# <br /> Sump Diameter: 36" 36" <br /> Sump Depth: 59" 59" <br /> Sump Material: FG FG <br /> Height from Tank Top to Top of 27" 27" <br /> Highest Piping Penetration: <br /> Height from Tank Top to Lowest 19" 19" <br /> Electrical Penetration: <br /> Condition of sump prior to testing: FAIR FAIR <br /> Portion of Sump Tested' <br /> Does turbine shut down when <br /> sump sensor detects liquid(both ®Yes❑No❑NA ®Yes❑Nc❑NA ❑Yes❑No❑NA ❑Yes❑No❑NA <br /> product and water)?* <br /> Turbine shutdown response time 6 SEC 6 SEC <br /> Is system programmed for fail-safe <br /> ®Yes❑No[INA ®Yes ElNo[INA El Yes ElNo[INA ❑Yes El NO ElNA <br /> shutdown?' <br /> Was fail-safe verified to be <br /> ®Yes❑No ElNA ®Yes❑No[INA El Yes❑No ElNA ❑Yes ElNo ElNA <br /> operational?* <br /> Wait time between applying <br /> pressure/vacuum/water and starting 15 MIN 15 MIN <br /> test: <br /> Test Start Time: 2:28 3:23 <br /> Initial Reading(Ri): 27356 45175 <br /> Test End Time: 2:43 3:39 <br /> Final Reading(RF): 27018 45163 <br /> Test Duration: 15 MIN 15 MIN <br /> Change in Reading(RF%): 0.0038 0.0012 <br /> Pass/Fail Threshold or Criteria: 0.002 0.002 <br /> test Result: ❑Pass ®Fail EODPos ❑Fair. [ ]Pass ' []'Fail ❑;Pass [I Fail <br /> Was sensor removed for testing? ®Yes❑No❑NA ®Yes❑No❑NA Q Yes❑No❑NA ❑Yes❑No❑NA <br /> Was sensor properly replaced and ®Yes❑No❑NA ®Yes❑No❑NA ❑Yes❑No❑NA ❑Yes❑No[INA <br /> verified functional after testing? <br /> Comments—(include information on repairs made prior to testing, and recommendedfollow-up forfailed tests) <br /> 8/24/16—RE-TESTED DSL 2 SIPHON&PASSED. <br /> If the entire depth of the sump is not tested,specify how much was tested. If the answer to gay of the questions indicated with an <br /> asterisk(*)is"NO"or"NA",the entire sump must be tested. (See SWRCB LG-160) <br /> Secondary Containment Test Results 9 of 15 <br />
The URL can be used to link to this page
Your browser does not support the video tag.