My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2016 - 2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CHARTER
>
1033
>
2300 - Underground Storage Tank Program
>
PR0232352
>
COMPLIANCE INFO_2016 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/26/2022 2:10:29 PM
Creation date
11/2/2018 4:33:55 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016 - 2018
RECORD_ID
PR0232352
PE
2361
FACILITY_ID
FA0003829
FACILITY_NAME
VANCO TRUCK-AUTO PLAZA
STREET_NUMBER
1033
Direction
W
STREET_NAME
CHARTER
STREET_TYPE
WAY
City
STOCKTON
Zip
95206
APN
16323041
CURRENT_STATUS
01
SITE_LOCATION
1033 W CHARTER WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\C\CHARTER\1033\PR0232352\COMPLIANCE INFO 2016 - 2017.PDF
QuestysFileName
COMPLIANCE INFO 2016 - 2017
QuestysRecordDate
8/8/2018 11:06:32 PM
QuestysRecordID
3201703
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
330
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
. RECEIVED <br /> SEP 2 8 2016 <br /> 22. FILL RISER CONTAINMENT SUMP TESTING <br /> Facility is Not Equipped With Fill Riser Containment Sumps❑ ENVH <br /> Fill Riser Containment Sumps are Present,but were Not Tested❑ <br /> Test Method Developed By: ❑Sump Manufacturer N Industry Standard ❑Professional ngineer <br /> ❑Other(Spec() <br /> Test Method Used: ❑Pressure ❑Vacuum N Hydrostatic <br /> ❑Other(Specify) <br /> Test Equipment Used:INCON TS-STS Equipment Resolution:0.0001 <br /> Fill Sump#DSL 2 Fill Sump#TRANS Fill Sump# Fill Sump# <br /> FILTER <br /> Sump Diameter: 38" <br /> Sump Depth: 68" <br /> Height from Tank Top to Top of 18" <br /> Highest Piping Penetration: <br /> Height from Tank Top to Lowest 16" <br /> Electrical Penetration: <br /> Condition of sump prior to testing: FAIR FAHt <br /> Portion of Sump Tested 25" <br /> Sump Material: FG <br /> Wait time between applying 15 MIN 15 MIN <br /> pressure/vacuum/water and starting <br /> test: <br /> Test Start Time: 1:54 3:23 <br /> Initial Reading(R,): 32081 46584 <br /> Test End Time: 2:09 3:39 <br /> Final Reading(RF): 32088 46587 <br /> Test Duration: 15 MIN 15 MIN <br /> Chane in Reading RF-R,): 0.0007 0.0003 <br /> Pass/Fail Threshold or Criteria: 0.002 0.002 <br /> Test Result: 0 Pass 0 Fail: Z Pass 0 Fall 0 Piss 0 Fail Pass -'at7 <br /> Is there a sensor in the sump? N Yes 0 No 0 Yes 0 No 0Yes No Yes No <br /> Does the sensor alarm when either N Yes❑No❑NA N Yes❑No❑NA ❑Yes❑No❑NA ❑Yes❑No❑NA <br /> product or water is detected? <br /> Was sensor removed for testing? I N Yes El No Ej NA N Yes 0 No LJ NA 0 Yes No NA 0 Yes LJ No LJ NA <br /> Was sensor properly replaced and N Yes LJ No LJ NA Yes LJ No LJ NA Lj Yes❑No Lj NA Lj Yes❑No Lj NA <br /> verified functional after testing? <br /> Comments—(include information on repairs made prior to testing, and recommended follow-up for failed tests) <br /> Secondary Containment Test Results 15 of 15 <br />
The URL can be used to link to this page
Your browser does not support the video tag.