Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016 - 2018
RECORD_ID
PR0232352
PE
2361
FACILITY_ID
FA0003829
FACILITY_NAME
VANCO TRUCK-AUTO PLAZA
STREET_NUMBER
1033
Direction
W
STREET_NAME
CHARTER
STREET_TYPE
WAY
City
STOCKTON
Zip
95206
APN
16323041
CURRENT_STATUS
01
SITE_LOCATION
1033 W CHARTER WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\C\CHARTER\1033\PR0232352\COMPLIANCE INFO 2016 - 2017.PDF
QuestysFileName
COMPLIANCE INFO 2016 - 2017
QuestysRecordDate
8/8/2018 11:06:32 PM
QuestysRecordID
3201703
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
330
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SEP 2 S 2016 <br /> 21. FILL RISER CONTAINMENT SUMP TESTING <br /> Facility is Not Equipped With Fill Riser Containment Sumps❑ MENTAL H <br /> Fill Riser Containment Sumps are Present,but were Not Tested❑ nPPARTMENT <br /> Test Method Developed By: ❑Sump Manufacturer ®Industry Standard ❑Professional Engineer <br /> ❑Other(Spec() <br /> Test Method Used: ❑Pressure ❑vacuum ®Hydrostatic <br /> ❑Other(Spec) <br /> Test Equipment Used:INCON TS-STS Equipment Resolution:0.0001 <br /> Fill Sump#OCT. Fill Sump#87 Fill Sump#91 Fill Sump#DSL I <br /> 100 <br /> Sump Diameter: 38" 38" 38" 38" <br /> Sump Depth: 71" 70" 69" 68" <br /> Height from Tank Top to Top of 21" 20" 21" 21" <br /> Highest Piping Penetration: <br /> Height from Tank Top to Lowest 24" 21" 24" 16" <br /> Electrical Penetration: <br /> Condition of sump prior to testing: FAIR FAIR FAIR FAIR <br /> Portion of Sump Tested 30" 30" 31" 28" <br /> Sum Material: FG FG FG FG <br /> Wait time between applying 15 MIN 15 MIN 15 MIN 15 MIN <br /> pressure/vacuum/water and starting <br /> test: <br /> Test Start Time: 11:31 12:18 11:31 12:57 <br /> Initial Reading(R): 35881 42371 47029 23914 <br /> Test End Time: 11:46 12:34 11:46 1:13 <br /> Final Reading ): 35881 42366 47031 23901 <br /> Test Duration: 15 MIN 15 MIN 15 MIN 15 MIN <br /> Change in Read' -Rj): 0 0.0005 0.0002 0.0013 <br /> Pass/Fail Threshold or Criteria: 0.002 0.002 0.002 0.002 <br /> Test Result: Pass Fail: Pass Fsl Pass Fail Pass Fail <br /> Is there a sensor in the sump9 LQ Yes Li No N Yes Lj No Z Yes No <br /> Does the sensor alarm when either Z Yes❑No❑NA ®Yes 1:1No E3NA ®Yes❑No❑NA ®Yes❑No❑NA <br /> product or water is detected? <br /> Was sensor removed for test ? Yes No NA Yes No NA Yes No NA Yes No NA <br /> Was sensor properly replaced and Yes No NA Yes No NA Z Yes No NA Yes No NA <br /> verified functional after testing? <br /> ConaILents—(include information on repairs made prior to testing, and recommendedfollow-up for failed tests) <br /> Secondary Containment Test Results 14 of 15 <br />