My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2016 - 2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CHARTER
>
1033
>
2300 - Underground Storage Tank Program
>
PR0232352
>
COMPLIANCE INFO_2016 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/26/2022 2:10:29 PM
Creation date
11/2/2018 4:33:55 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016 - 2018
RECORD_ID
PR0232352
PE
2361
FACILITY_ID
FA0003829
FACILITY_NAME
VANCO TRUCK-AUTO PLAZA
STREET_NUMBER
1033
Direction
W
STREET_NAME
CHARTER
STREET_TYPE
WAY
City
STOCKTON
Zip
95206
APN
16323041
CURRENT_STATUS
01
SITE_LOCATION
1033 W CHARTER WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\C\CHARTER\1033\PR0232352\COMPLIANCE INFO 2016 - 2017.PDF
QuestysFileName
COMPLIANCE INFO 2016 - 2017
QuestysRecordDate
8/8/2018 11:06:32 PM
QuestysRecordID
3201703
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
330
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209) 468-3420 Fax: (209)468-3433 Web:www.siaov.org�ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> VANCO TRUCK AUTO PLAZA 1033 W CHARTER WAY, STOCKTON June 22, 2017 <br /> SUMMARY OF VIOLATIONS <br /> {CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 209 CCR 2715(c) Designated operator did not inspect all required items and/or the inspection reports not completed. <br /> The designated operator failed to document all the alarms from the attached alarm history on the May 2017 <br /> designated operator monthly inspection report and failed to check that they were responded to appropriately. The <br /> missing alarm includes: L18 alarm 3-21-2017 . During the monthly inspection, the designated operator shall review <br /> the alarm history for the previous month, check that each alarm was documented and responded to appropriately, <br /> and attach a copy of the alarm history with documentation taken in response to any alarms to the monthly report. <br /> Ensure that designated operators performing monthly inspections at this facility are including all of the required <br /> information on the reports. <br /> Submit proof of correction to the EHD. <br /> This is a Class II violation. <br /> 211 CCR 2715(f) Designated operator employee training not performed or log not kept. <br /> The designated operator employee training for Asia Buckley was performed on 5-9-2017 and her hire date was <br /> listed as 3-1-2017. The designated operator shall train facility employees for which he or she is responsible in the <br /> proper operation and maintenance of the UST system once every 12 months. The initial training shall be conducted <br /> within 30 days of the date of hire. <br /> The training shall include, but is not limited to: <br /> 1. Operation of the UST system in a manner consistent with the facility's best management practices <br /> 2. Employee's role with regard to monitoring equipment as specified in the facility's monitoring plan <br /> 3, Employee's role with regard to spills and overfills as specified in the facility's response plan <br /> 4. Name of the contact person(s)for emergencies and monitoring equipment alarms <br /> Ensure that employees have been trained by the designated operator, maintain the list on site. <br /> This is a Class II violation. <br /> 301 HSC 25292.1 UST system is not operated to prevent unauthorized release, including spills and overfills. <br /> Stained oily pavement was observed at the satellite dispenser 11 at the time of inspection . The underground <br /> storage tank system shall be operated to prevent unauthorized releases. The nozzle was tightened and absorbent <br /> was applied to stained surface at the time of inspection, waste absorbent was placed into the onsite hazardous <br /> waste container pending disposal. <br /> This was corrected on site. <br /> This is a Class II violation. <br /> 307 CCR 2632(c) Monitoring system of the interstitial space of a double walled system not maintained. <br /> The racing fuel annular sensor failed to activate an audible and visual alarm when tested and, therefore, the tank is <br /> not monitored. The interstitial space shall be monitored with a monitoring system connected to an audible and <br /> visual alarm system. Immediately contact a properly licensed, trained, and certified contractor to replace the failed <br /> component with a functional component (LG 113-x listed, if applicable) under permit and inspection procedures of <br /> the EHD within one business day. <br /> This is a Class II violation. <br /> FA0003829 PR0232352 SCO01 0&22•12017 <br /> EHf3 23-01 Rev.09(22116 Page 5 of 6 Underground Storage Tank Program CIR <br />
The URL can be used to link to this page
Your browser does not support the video tag.