Laserfiche WebLink
i <br /> STATE OF CALIFORNIP WATER RESOURCESCONTRO' 90ARD "'•" \ <br /> FORM 'S': UNDEKGROUND STORAGE TANK PRO"RAM a <br /> TANK PERMIT APPLICATION INFORMATION y ° <br /> TANK COMPLETE A SEPARATE FORM WITH THE FOLLOWING INFORMATION FOR EACH TANK. a z <br /> to <br /> MARK ONLY ❑ I NEW PERMIT ❑ 3 RENEWAL PERMIT ❑ 5 CHANGE OF INFORMATION ❑ 7 PERMANENTLY CLOSED TANK <br /> ONE ITEM ❑ 2 INTERIM PERMIT ❑ 4 AMENDED PERMIT ❑ 6 TEMPORARY TANK CLOSURE ❑B TANK REMOVED /C)— CJ.) <br /> FACILITY/SITE NAME WHERE TANK IS INSTALLED: FARM TANK-YES❑ NO ❑ <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS-IF UNKNOWN—SO SPECIFY <br /> v <br /> A. OWNERS TANK IDp B. MANUFACTURED BY: <br /> C. YEAR INSTALLED D. TANK CAPACITY IN GALLONS. <br /> 11. TANK CONTENTS IF(A.1),IS MARKED,COMPLETE ITEM C.IF(A.1),IS NOT MARKED,COMPLETE ITEM D. <br /> A. ❑ 1 MOTOR VEHICLE FUEL ❑ 2 PETROLEUM B. C. ❑ I UNLEADED ❑ 2 LEADED ❑ 3 DIESEL <br /> ❑ 3 CHEMICAL PRODUCT ❑ 4 OIL ❑ I PRODUCT ❑4 GASAHOL ❑ 5 JET FUEL ❑ 6 AVIATION GAS <br /> ❑ 5 HAZARDOUS ❑ 80 EMP N ❑ 95 UNKNOWN ❑ 2 WASTE ❑ 7 METHANOL ❑ 99 OTHER(DESCRIBE IN ITEM D,BELOW) <br /> D. IF NOT MOTOR VEHICLE FUEL,ENTER NAME OF <br /> HAZARDOUS SUBSTANCE STORED 8 C.A.S.X C.A.S.X'. <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOK A,B,C,IS D <br /> TYPE <br /> GLE WALLED WITH <br /> 95 UNKNOWN <br /> A F ❑ 2 SINGLE WALLED E] 4 SEI <br /> SYSTEMSECONDARY CONTAINMENT 99 <br /> LINER a N OTHEER <br /> ❑ I STEEL/IRON ❑2 STAINLESS STEEL ❑ 3 FIBERGLASS ❑ 4 STEEL CUD W/FIBERGLASS REINFORCED PLASTIC <br /> B.TANK ❑ 5 CONCRETE ❑ 6 POLYVINYLCHLORIDE ❑ 7 ALUMINUM ❑ 8 100%METHANOL COMPATIBLE FRP <br /> MATERIAL <br /> ❑9 BRONZE ❑ IO GALVANIZED STEEL ❑ 95 UNKNOWN ❑ 99 OTHER <br /> C. INTERIOR ❑ I RUBBER LINED ❑2 ALIOD LINING ❑3 EPDXY LINING ❑ 4 PHENOLIC LINING <br /> LINING ❑5 GLASS LINING ❑ 6 UNLINED ❑ 95 UNKNOWN <br /> ❑ IS LINING MATERIAL COMPATIBLE WITH 100%METHANOL? ❑YES ❑ NO ❑ 99 OTHER <br /> D. CORROSION ❑ I POLYUHLENEWPAP ❑ 2 TAR OR ASPHALT ❑ 3 VINYL WRAP ❑4 FIBERGLASS REINFORCED PLASTIC <br /> PROTECTION ❑ 5 CATHODIC PROTECTION ❑ 91 NONE ❑ 95 UNKNOWN ❑99 OTHER <br /> IV. PIPING INFORMATION CIRCLE A IF ABOVE GROUND, U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A SYSTEM TYPE A U I SUCTION A U 2 PRESSURE A U 3 GRAVITY A U 91 NONE A U 95 UNKNOWN A U 99 OTHER <br /> B.CONSTRUCTION A U I SINGLE WALLED A U 2 DOUBLE WALLED A U 3 LINED TRENCH A U 91 NONE A U 95 UNKNOWN A U 99 OTHER <br /> A U I STEELMRON A U 2 STAINLESS STEEL A U 3 POLYVINYL CHLORIDE(PVC) A U 4 FIBERGLASS PIPE A U 91 NONE <br /> C. MATERIAL A U 5 ALUMINUM A U 6 CONCRETE A U 7 STEEL CUD W/FRP A U 8 100%METHANOL COMPATIBLE FRP <br /> A U 9 GALVANIZED STEEL A U 95 UNKNOWN A U 99 OTHER <br /> V. LEAK DETECTION SYSTEM CIRCLE P FOR PRIMARY,OR S FOR SECONDARY,A PRIMARY LEAK DETECTION SYSTEM MUST BE CIRCLED. <br /> P 8 t VISUAL CHECK P 8 2 INVENTORY RECONCILIATION P 8 3 VADOSE WELLS P 8 4 ELECTRONIC MONITOR P 8 5 GROUND WATER MONITORING WELLS <br /> P S 6 PRECISION TESTING P 8 7 PRESSURE TESTING P 8 91 NONE P 8 95 UNKNOWN P 8 99 OTHER <br /> VI. INFORMATION ON TANK PERMANENTLY CLOSED IN PLACE <br /> 1.ESTIMATED DATE UST USED(MO/YR) 2. ESTIMATED QUANTITY OF 3, WAS TANK FILLED WITH <br /> SUBSTANCE REMAINING IN GALLONS INERT MATERIAL? ❑YES [_ NO <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE, IS TRUE AND CORRECT. <br /> APPLICANTS NAME(PRINTED A SIGNATURE) DATE <br /> LOCAL AGENCY USE ONLY <br /> COUNTY B JURISDICTION N AGENCY S FACILITY ID M TANK ID X _ <br /> CURRENT LOCAL AGENCY FACILITY ID• APPROVED BY NAME PHONE S WITH AREA CODE <br /> 13, <br /> PERMIT NUMBER PERMIT APPROVAL DATE PERMIT EXPIRATION DATE b <br /> CHECK A PERMIT AMOUNT -- SURCHARGE AMT. FEE CODE - SECEIPT I BY: <br /> FgRM B Isaosel THIS FORM MUST BE ACCOMPANIED BY A FACILITY/SITE APPLICATION, F0 FJ M 'A',UMLF9S A CI RIRFNT XOP"'A' HAS^FSH Fu FO <br />