My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CHARTER
>
1313
>
2300 - Underground Storage Tank Program
>
PR0231049
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/16/2021 12:03:21 AM
Creation date
11/2/2018 4:39:43 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0231049
PE
2381
FACILITY_ID
FA0003765
FACILITY_NAME
AIRPORT SHELL*
STREET_NUMBER
1313
Direction
E
STREET_NAME
CHARTER
STREET_TYPE
WAY
City
STOCKTON
Zip
95205
APN
15137007
CURRENT_STATUS
02
SITE_LOCATION
1313 E CHARTER WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\C\CHARTER\1313\PR0231049\BILLING.PDF
QuestysFileName
BILLING
QuestysRecordDate
5/9/2014 6:00:58 PM
QuestysRecordID
116724
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
99
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
i <br /> STATE OF CALIFORNIA WATER RESOURCES CONTROI -TOARDT y <br /> FORM 'B': UNDEH6ROUND STORAGE TANK PROUIiAM <br /> TANK TANK PERMIT APPLICATION INFORMATION ° " <br /> COMPLETE A SEPARATE FORM WITH THE FOLLOWING INFORMATION FOR EACH TANK. z <br /> 10 <br /> MARK ONLY ❑ 1 NEW PERMIT ❑ 3 RENEWAL PERMIT ❑ 5 CHANGE OF INFORMATION ❑ 7 PERMANENTLY CLOSED TANK <br /> ONE ITEM ❑ 2 INTERIM PERMIT 4 AMENDED PERMIT ❑ 6 TEMPORARY TANK CLOSURE 0 TANK REMOVED &-- <br /> W <br /> FACILITY/SITE NAME WHERE TANK IS INSTALLED: FARM TANK-YES❑ NO ❑ I-` <br /> co <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS-IF UNKNOWN-SO SPECIFY LI <br /> A. OWNERS TANK IDN B. MANUFACTURED BY. <br /> C. YEAR INSTALLED I D. TANK CAPACITY IN GALLONS <br /> II. TANK CONTENTS IF(A.1),IS MARKED,COMPLETE ITEM C.IF(A.1),IS NOT MARKED,COMPLETE ITEM D. <br /> A. ❑ 1 MOTOR VEHICLE FUEL ❑ 2 PETROLEUM B. C. 0 I UNLEADED ❑ 2 LEADED ❑3 DIESEL <br /> ❑3 CHEMICAL PRODUCT ❑4 OIL ❑ 1 PRODUCT ❑ 4 GASAHOL ❑5 JET FUEL ❑6 AVIATION GAS <br /> ❑5 HAZARDOUS ❑ 00 EMPTY ❑95 UNKNOWN ❑ 2 WASTE ❑ 7 METHANOL ❑99 OTHER(DESCRIBE IN ITEM D,BELOW) <br /> D. IF NOT MOTOR VEHICLE FUEL,ENTER NAME OF <br /> HAZARDOUS SUBSTANCE STORED 6 CA.S,N C.A.S.N: <br /> Ill. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOK A,B,C,A D <br /> A TYPE OF ❑ I DOUBLEWAuED ❑ 3 SINGLE WALLED WITH EXIERKM UNBI F-195 UNKNOWN <br /> SYSTEM ❑2 SINGLE WALLED ❑ 4 SECONDARY CONTAINMENT ❑99 OTHER <br /> ❑ I STEEUIRON ❑2 STANAESSSTEEL ❑3 FIBERGLASS ❑4 STEEL CUD W/FIBERGLASS REINFORCED PLASTIC <br /> B.TANK ❑ 5 CONCRETE ❑6 POLYVINYLCHLORIDE ❑7 ALUMINUM ❑A 100%METHANOL COMPATIBLE FRP <br /> MATERIAL <br /> ❑ 9 BRONZE ❑ 10 GALVANIZED STEEL ❑95 UNKNOWN ❑99 OTHER <br /> ❑ I RUBBERUNED ❑ 2 ALKYD LINING ❑ 3 EPDXY UNIW ❑4 PHENOLIC LINING <br /> G INTERIOR <br /> LINING ❑ 5 GLASS LINING NG 6 UNLINED 95 UNKNOWN <br /> ❑B LINING MATERIAL COMPATIBLE WITH 100%METHANOL? ❑YES ❑NO ❑99 OTHER <br /> D. CORROSION ❑ 1 POLYETHIENEWRAP ❑2TAR OR ASPHALT ❑3VIWLWRAP ❑ 4 FIBERGLASS REINFORCED PLASTIC <br /> PROTECTION ❑ 5 CATHODIC PROTECTION ❑91 NONE ❑95 UNKNOWN ❑ 99 OTHER <br /> IV. PIPING INFORMATION CIRCLE A IF ABOVE GROUND, U IF UNDERGROUND.BOTH IF APPLICABLE <br /> A SYSTEM TYPE A U I SUCTION A U 2 PRESSURE A U 3 GRAVITY A U 91 NONE A U 95 UNKNOWN A U 99 OTHER <br /> B. CONSTRUCTION A U I SINGLE WALLED A U 2 DOUBLE WALLED A U 3 LINED TRENCH A U 91 NONE A U 95 UNKNOWN A U 99 OTHER <br /> A U I STEEL/IRON A U 2 STAINLESSSTEEL A U 3 POLYVINYL CHLORIDE(PVC) A U 4 FIBERGLASSPIPE A U 91 NONE <br /> C. MATERIAL A U 5 ALUMINUM A U 6 CONCRETE A U 7 S7EELCHADW/FRP A U 8108%METHANOL COMPATIBLE FRP <br /> A U 9 GALVANIZED STEEL A U 95 UNKNOWN A U 99 OTHER <br /> V. LEAK DETECTION SYSTEM CIRCLE P FOR PRIMARY,OR S FOR SECONDARY,A PRIMARY LEAK DETECTION SYSTEM MUST BE CIRCLED. <br /> P f ' VISUAL CHECK P 8 2 INVENTORY RECONCILIATION P t 3 VADOSE WELLS P 8 4 ELECTRONIC MONITOR P { 5 GROUND WATER MONITORING WELLS <br /> 8 6 PRECISION TESTING P t 1 PRESSURE TESTING P { 91 NONE P t 95 UNKNOWN P t 99 OTHER <br /> VI. INFORMATION ON TANK PERMANENTLY CLOSED IN PLACE <br /> 1. ESTIMATED DATE LAST USED(MO/YR) 2. ESTIMATED OUANTITY OF 3.WAS TANK FILLED WITH <br /> SUBSTANCE REMAINING IN GALLONS INERT MATERIAL? ❑YES E]NO <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE,IS TRUE AND CORRECT. <br /> APPLICANT'S NAME(PRINTED 6 SIGNATURE) DATE <br /> LOCAL AGENCY USE ONLY <br /> COUNTY N JURISDICTION N AGENCY N FACILITY ID N TANK IO N _ <br /> CURRENT LOCAL AGENCY FACILITY ID N APPROVED BY NAME �y (y PHONE N WITH AREA CODE <br /> PERMIT NUMBER PERMIT APPROVAL DATE PERMIT EXPIRATION DATE <br /> CHECK I PERMIT AMOUNT '-- RURCHARGE AMT. FEE CODE ARECEIPT I BY: <br /> PORM R 1529 88) THIS FORM MUST BE ACCOMPANIED BY A FACILITY/SITE APPLICATION, FORM 'A',UNLESS A CURRENT FORM A• HAS PFFN FII ED <br />
The URL can be used to link to this page
Your browser does not support the video tag.