My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2003 - 2007
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CHEROKEE
>
610
>
2300 - Underground Storage Tank Program
>
PR0521866
>
COMPLIANCE INFO_2003 - 2007
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/20/2021 3:49:10 PM
Creation date
11/2/2018 5:10:41 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2003 - 2007
RECORD_ID
PR0521866
PE
2371
FACILITY_ID
FA0014852
FACILITY_NAME
RANCHO SAN MIGUEL MARKET*
STREET_NUMBER
610
Direction
S
STREET_NAME
CHEROKEE
STREET_TYPE
Ln
City
Lodi
Zip
95240
APN
04745039
CURRENT_STATUS
01
SITE_LOCATION
610 S Cherokee Ln
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\wng
Supplemental fields
FilePath
\MIGRATIONS\C\CHEROKEE\612\PR0521866\COMPLIANCE INFO 2003 - 2007 .PDF
QuestysFileName
COMPLIANCE INFO 2003 - 2007
QuestysRecordDate
10/28/2016 6:58:12 PM
QuestysRecordID
3244411
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
125
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Page 5 of 7 <br /> 7. UNDER-DISPENSER CONTAINMENT TESTING <br /> Test Method Developed By: D UDC Manufacturer X Industry Standard D Professional Engineer <br /> D Other(Specify) <br /> Test Method Used: D Pressure D Vacuum X Hydrostatic <br /> D Other(Sped) <br /> Test Equipment Used: lion TS-STS Equipment Resolution; <br /> UDC# 12 UDC#34 UDC# UDC# <br /> UDC Manufacturer: Environ Environ <br /> UPC Material: Poly Poly <br /> UDC D 33" 33" <br /> Height from UDC Bottom to Top 4" 4" <br /> Penetration:oHmUiC <br /> Bottom to 15" 15" <br /> Lowest Electrical Penetration: <br /> Condition of UDC prior to Clean Clean <br /> testing: <br /> Portion of UDC Tested Full Full <br /> Does turbine shut down when <br /> UDC sensor detects liquid(both XYes ONo DNA XYes ONo DNA O Yes LI No O NA D Yes ONo [INA <br /> product and water 7° <br /> Turbine shutdown nes use time 2 Seconds 2 Seconds <br /> is system programmed for fail- XYes ONo [INA X Yes D No DNA O Yes ONo [INA n Yes ONo DNA <br /> safe shutdown? <br /> Was fail-safe verified to be XYes ONo DNA XYes ONo [INA Oyes ONo DNA OYes ONo DNA <br /> o erational7 <br /> Wait time between applying 15 minutes 15 minutes <br /> pressure/vacuum/water and <br /> starting test <br /> Test Start Time: 7:33 am 8:43am <br /> Initial Read' 1.7603" 5.3564" <br /> Test End Time: 7:48 am 8:58 am <br /> Final Reading(P,,): 1.7592" 5.3554" <br /> Test Duration: 15 minutes 15 minutes <br /> Change at Re RFRt : .0009"loss .001" <br /> Pass/Fail Threshold or Criteria: Loss<002"-pass Loss<•002"=pass. <br /> Test Result; X Pats O Fall X Pass O Fall O Pass O Fmil O Pala O Fail <br /> Was sensor removed for testing? X Yes O No DNA XYes ONo DNA I O Yes ONo DNA D Yea D No O NA <br /> Was sensor properly replaced and XYes ONo DNA XYes ONo DNA D Yes O No O NA D Yes D No O NA <br /> verified functional after testing? <br /> COMMetlt8—(include information on repairs made prior to testing, and recommen_ded fi low-ap for failed tarts) <br /> Tighten all clamps retest wit n a-e5,_ <br /> ' If the entire depth of the UDC is not tested,specify how much was tested. if the answer to pOr y ofthe questions indicated with an <br /> asterisk(")is"NO"or"NA",the entire(IDC must be tested. (See SWRCB LG-160) <br />
The URL can be used to link to this page
Your browser does not support the video tag.