My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2016 - 2017
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CHEROKEE
>
610
>
2300 - Underground Storage Tank Program
>
PR0521866
>
COMPLIANCE INFO_2016 - 2017
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/20/2021 3:49:10 PM
Creation date
11/2/2018 5:12:07 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016 - 2017
RECORD_ID
PR0521866
PE
2371
FACILITY_ID
FA0014852
FACILITY_NAME
RANCHO SAN MIGUEL MARKET*
STREET_NUMBER
610
Direction
S
STREET_NAME
CHEROKEE
STREET_TYPE
Ln
City
Lodi
Zip
95240
APN
04745039
CURRENT_STATUS
01
SITE_LOCATION
610 S Cherokee Ln
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\wng
Supplemental fields
FilePath
\MIGRATIONS\C\CHEROKEE\612\PR0521866\COMPLIANCE INFO 2016 - PRESENT.PDF
QuestysFileName
COMPLIANCE INFO 2016 - PRESENT
QuestysRecordDate
11/1/2016 3:06:35 PM
QuestysRecordID
3247087
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
158
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
.RECENED <br /> SEP 2 2 2016 <br /> 8. FILL RISER CONTAINMENT SUMP TESTING <br /> Facility is Not Equipped With Fill Riser Containment Sumps ❑ ENVIRONMEN UOL H <br /> EALI <br /> Fill Riser Containment Sumps are Present,but were Not Tested ❑ DEPARTMEN f <br /> Test Method Developed By: ❑ Sump Manufacturer M Industry Standard ❑Professional Engineer <br /> ❑Other(Spec) <br /> Test Method Used: ❑Pressure ❑Vacuum ®Hydrostatic <br /> ❑ Other(Spec) <br /> Test Equipment Used: Incon Sump Tester Equipment Resolution_ +/-0.002" <br /> Fill Sump#87 �ry Fill Sump 91 <br /> Sump Diameter: 42" 42" <br /> Sump Depth: 52" 53" <br /> Height from Tank Top to Top of 18" 16' <br /> Highest Piping Penetration: _ { <br /> Height from Tank Top to Lowest 22„ 191, ! <br /> Electrical Penetration: <br /> Condition of sump prior to Good Good <br /> testing: _ <br /> Portion of Surnp Tested 2"above piping 2"above pipingi <br /> Sump Material: Fiberglass Fiberglass I <br /> Wait time between applying <br /> pressure/vacuum/water and 30 minutes 30 minutes <br /> starting test: <br /> Test Start Time: 11:36 am 11:53 am <br /> Initial Reading Rj): 4.0112 2.1134 <br /> Test End Time: 11:51 am 12:08 put <br /> Final Reading RF : 4.0108 2.1133 <br /> Test Duration: 15 min. 15 min. <br /> Change in Reading(RF-Rj): 0.0004 0.0001 <br /> Pass/Fail Threshold or Criteria: +/_0,002" +/-0.002" <br /> Test Result: ID Pass ❑Fail © Pass ❑Fail <br /> Is there a sensor in the sump? ®Yes ❑No ® Yes ❑No <br /> Does the sensor alarm when <br /> either product or water is ❑ Yes❑No®NA ❑ Yes❑No®NA <br /> detected? <br /> Was sensor removed for testing? ® Yes❑No❑NA M Yes❑No❑NA <br /> Was sensor properly replaced and ®yes❑No❑ NA ®Yes ❑No❑ NA <br /> verified functional after testing? <br /> Comments—(include information on repairs made prior to testing, and recommended follow-up for failed tests) <br /> Sensor functionality was not confirmed.This procedure is not part of the Secondary Containment testing scope of work <br /> `t <br />
The URL can be used to link to this page