My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2016 - 2017
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CHEROKEE
>
610
>
2300 - Underground Storage Tank Program
>
PR0521866
>
COMPLIANCE INFO_2016 - 2017
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/20/2021 3:49:10 PM
Creation date
11/2/2018 5:12:07 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016 - 2017
RECORD_ID
PR0521866
PE
2371
FACILITY_ID
FA0014852
FACILITY_NAME
RANCHO SAN MIGUEL MARKET*
STREET_NUMBER
610
Direction
S
STREET_NAME
CHEROKEE
STREET_TYPE
Ln
City
Lodi
Zip
95240
APN
04745039
CURRENT_STATUS
01
SITE_LOCATION
610 S Cherokee Ln
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\wng
Supplemental fields
FilePath
\MIGRATIONS\C\CHEROKEE\612\PR0521866\COMPLIANCE INFO 2016 - PRESENT.PDF
QuestysFileName
COMPLIANCE INFO 2016 - PRESENT
QuestysRecordDate
11/1/2016 3:06:35 PM
QuestysRecordID
3247087
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
158
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
RECE VEE <br /> SEP 2 2 2016 <br /> 7. UNDER-DISPENSER CONTAINMENT(UDC)TESTING <br /> Test Method Developed By: ❑ UDC Manufacturer ®Industry Standard CIV V ftW bM! HEW <br /> ❑ Other(Spec) <br /> Test Method Used: ❑Pressure Cl Vacuum ®Hydrostauc <br /> ❑ Other(Specify) <br /> Test Equipment Used: Incon Sump Tester Equipment Resolution: +/-0.002" <br /> UDC#1/2 UDC#3/4 UDC#5/6 <br /> UDC Manufacturer: Environ Environ Environ <br /> UDC Material: Poly Poly Poly <br /> UDC Depth: 31" 31" 31" <br /> Height from UDC Bottom to Top 12" 12" 12" <br /> of Highest Piping Penetration: <br /> Height from UDC Bottom to <br /> Lowest Electrical Penetration: <br /> Condition of UDC prior to Good Good Good <br /> testing: <br /> Portion of UDC Tested 2"above i in 2"above i in 2"above virina <br /> Does turbine shut down when <br /> UDC sensor detects liquid(both ❑Yes❑No ®NA ❑Yes❑No ®NA ❑Yes❑No RNA <br /> product and water)?* <br /> Turbine shutdown response time N/A N/A N/A <br /> Is system programmed for fail- ❑ Yes❑No ®NA ❑Yes❑No RNA ❑Yes❑No RNA <br /> safe shutdown? <br /> Was fail-safe verified to be El Yes❑No ®NA ❑Yes❑No RNA ❑Yes❑No ®NA <br /> operational?* <br /> Wait time between applying <br /> pressure/vacuum/water and 30 minutes 30 minutes 30 minutes <br /> starting test <br /> Test Start Time: 2:23 pot 1:46 pro 2:04 pro <br /> Initial Reading(R,): 3.4649 3.4113 2.7298 <br /> Test End Time: 2:38 pm 2:01 pni 2:19 pro <br /> Final Reading(R,): 3.4652 3.4132 2.7303 <br /> Test Duration: 15 min. 15 min. 15 min. t <br /> Change in Reading(R,-R,): 0.0003 0.0019 0.0005 <br /> Pass/Fail Threshold or Criteria: +/-0.002" +1-0.002" +/-0.002" <br /> Test Result: ® Pass ❑Fail © Pass ❑Fail O Pass ❑Fail <br /> Was sensor removed for testing? M Yes❑No❑NA M Yes❑No❑NA M Yes ❑No❑NA <br /> ==after <br /> properly replaced and ®yes❑No❑NA ®Yes❑No❑NA ®Yes ❑No❑NA <br /> verified functional after testin ? <br /> Comments—(include information on repairs made prior to testing,and recommended follow-up forfailed tests) <br /> "Sensor functionality was not confirmed.This procedure is not part of the Secondary Containment testing scope of work". <br /> i <br /> If the entire depth of the UDC is not tested,specify how much was tested. If the answer to any of the questions indicated with an <br /> asterisk(*)is"NO"or"NA",the entire UDC must be tested. (See SWRCB LG-160) <br /> t <br />
The URL can be used to link to this page
Your browser does not support the video tag.