Laserfiche WebLink
RESNA SITE SAFETY PLAN <br />❑ Confined Space Entry (follow RESNA's Confined Space Entry Procedures) <br />❑ Other - explain hazard and mitigation <br />EXPOSURE MONITORING <br />All sample results will be recorded in the RESNA exposure log. Log copies are filed in the job file, and <br />in all site personnel's medical file, and maintained in the job file. All sampling instruments will be <br />calibrated per the manufacturers instructions on a daily basis. <br />Note calibration gas and any unusual calibration settings in the "monitoring equipment" <br />column. <br />Include monitoring for health hazards, explosion hazards, etc. <br />Monitoring <br />Hazard <br />Sample <br />Sample <br />Action <br />Equipment <br />Monitored <br />Location <br />Frequency <br />Level <br />Action <br />OVMIPID <br />Organic Vapors <br />Breathing Zone <br />15 MINUTES <br />20 PPM <br />112 Face <br />Respirator <br />OVMIPID <br />Organic Vapors <br />Breathing Zone <br />15 MINUTES <br />200 PPM <br />EVACUATE <br />Identify sample locations on site map. <br />NSPC-SSP PAGE 6 MAY 1994 <br />