My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2015 - 2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
COLONY
>
1340
>
2300 - Underground Storage Tank Program
>
PR0529124
>
COMPLIANCE INFO_2015 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/15/2022 2:22:42 PM
Creation date
11/2/2018 5:38:16 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2015 - 2018
RECORD_ID
PR0529124
PE
2351
FACILITY_ID
FA0019437
FACILITY_NAME
ARCO am/pm # 83230
STREET_NUMBER
1340
Direction
W
STREET_NAME
COLONY
STREET_TYPE
Rd
City
Ripon
Zip
95366
APN
261-590-110-000
CURRENT_STATUS
01
SITE_LOCATION
1340 W Colony Rd
P_LOCATION
05
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\C\COLONY\1340\PR0529124\COMPLIANCE INFO 2016 - PRESENT.PDF
QuestysFileName
COMPLIANCE INFO 2016 - PRESENT
QuestysRecordDate
10/26/2016 3:50:54 PM
QuestysRecordID
3092866
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
263
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
V- <br /> Monitoring System Certification '-.1_ � <br /> RECEN ' - <br /> D. Results of Testing/Servicing NOV 18 2016 <br /> Software Version Installed: 333.00 <br /> Com ilete the following checklist: ENVIRONMENTAL HEALTH <br /> E Yes ❑ No* is the audible ala m operational? <br /> E Yes ❑ No* Is the visual alarm operational? <br /> E Yes ❑ No* Were all sensors visually inspected,functionally tested,and confirmed o2ee <br /> tional? <br /> E Yes ❑ No* Were all sensors installed at lowest point of secondary containment andtioned so that other equipment will <br /> not interfere with their proper operation? <br /> ❑ Yes ❑ No* If alarms are relayed to a remote monitoring station, is all comcations equipment (e.g., modem) <br /> E N/A operational? <br /> E Yes ❑ No* For pressurized piping systems, does the turbine automatically shut dowthe piping secondary containment <br /> ❑ N/A monitoring system detects a leak, fails to operate,or is electrically discoted? If yes:which sensors initiate <br /> positive shut-down? (Check all that apply) E Sump/Trench Sensors; Epenser Containment Sensors. <br /> Did you confirm positive shut-down due to leaks and sensor failure/discotion? E Yes; ❑No. <br /> E Yes ❑ No* For tank systems that utilize the monitoring system as the primary overfill warning device (i.e., no <br /> ❑ N/A mechanical overfill prevention valve is installed), is the overfill warninrm visible and audible at the tank <br /> fill point(s)and operating properly? If so,at what percent of tank capacies the alarm trigger? 90%❑ Yes* E No Was any monitoring equipment replaced? If yes,identify specific sensorobes,or other equipment replacedand list the manufacturer name and model for all replacement parts in SecE,below.E Yes* ❑ NoWas liquid found inside any secondary containment systems designed as ystems? (Check all that apply)❑Product; E Water. If yes,describe causes in Section E,below. <br /> E Yes ❑ No* Was monitoring system set-up reviewed to ensure proper settings?Attachp reports,if applicableE Yes ❑ No* Is all monitor ng equipment operational per manufacturer's specifications <br /> *In Section E below,describe how and when these deficiencies were or will be corrected. <br /> E. Comments: Site has Vacuum sensors 332175-001 and Float assemblies 332117-001.STP and Fill sumps had <br /> liquid. Removed liquid from sumps and cleaned. Inspector Vickey McCartney on site. The vacuum communication <br /> alarm was not tested in the dispensers and the brine communication in the fill and STP sumps were not tested, only the <br /> brine dispensers were tested. Fills and STP sumps need ball valves to be installed in the bottom of the sumps for brine <br /> communication and the farthest dispenser needs test ports for vacuum communication. <br /> Page 2 of 4 <br />