Laserfiche WebLink
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209) 468-3420 Fax:(209)468-3433 Web:www.sj ov,or /ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: <br /> Sprint United Managemnt Co. 3807 Coronado Ave, Stockton Date: <br /> November 07, 2014 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to compiy) <br /> 763 <br /> Remarks <br /> 30(4) Monitoring equipment is not installed or maintained to detect a leak at the earliest opportunity. <br /> sel piping sump sensor was not at the lowest point and not located to detect a leak at the earliest opportunity.ing equipment shall be maintained to be able to detect a leak at the earliest possible opportunity. The sensor <br /> ocated to the lowest point of the sump during the inspection by the service technician. Ensure that all <br /> ing equipment is maintained to detect a leak at the earliest opportunity. This is a Class II violation. <br /> rader valve on the return line in the diesel piping sump was not facing downward. The return line is gravity fed, <br /> vents any releases from the primary containment from immediately flowing into the secondary containment. <br /> ypential release from the primary containment into the secondary containment in the diesel piping does not flow <br /> into a piping sump so that it can be detected at the earliest opportunity. All secondary containment systems shall be <br /> sloped so that all releases will flow to a collection sump located at the low point of the underground piping so that the <br /> monitoring equipment can detect a leak at the earliest opportunity. Immediately contact a properly licensed, trained, <br /> and certified contractor to ensure that any releases from the primary piping flows into the secondary containment piping <br /> sump so that a leak can be detected at the earliest opportunity. This is a Class 11 violation. <br /> Overall Inspection Comments: <br /> This report was amended on January 23, 2015. <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork, by December 7, 2014. <br /> Consent to perform the inspection, take photos and collect samples was given by Ken Carr the Manager . This <br /> facility's designated operator is Darren M. Rieck (iCC expiration date: 5/1/15 ) . The service technician was Peter <br /> J. Jauregui III (ICC expiration date: 6/13/15 ), who had the following manufacturer's certifications: VR,7/7/15 . <br /> Please be aware that as of January 1, 2014, facility operators are required to upload the following UST program <br /> documents into the California Environmental Reporting System (CERS). UST Monitoring Site Plan, UST <br /> Certification of Financial Responsibility, UST Response Plan, UST Owner/Operator: Written Agreement (if <br /> applicable), UST Letter from Chief Financial Officer, and Owner Statement of Designated UST Operator <br /> Compliance. <br /> AL E A ! I w Al I MPL A <br /> T T IL I L U E A <br /> THIS FACILITY IS SU_ BJECT TO REINSPECTION AT ANY TIME AT EH CURRENT HOURLY RATE. <br /> Received By{signature): Title: <br /> Date: <br /> Received By{printed name): Inspector: <br /> Inspector Phone: <br /> ARES VELOSO, Senior REHS (209)468-3453 <br /> Page 5of5 <br />