My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CORRAL HOLLOW
>
18600
>
2300 - Underground Storage Tank Program
>
PR0231543
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/1/2020 11:52:26 AM
Creation date
11/2/2018 6:18:18 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0231543
PE
2381
FACILITY_ID
FA0009373
FACILITY_NAME
CARNEGIE SVRA
STREET_NUMBER
18600
STREET_NAME
CORRAL HOLLOW
STREET_TYPE
RD
City
TRACY
Zip
95377
APN
25115002
CURRENT_STATUS
02
SITE_LOCATION
18600 CORRAL HOLLOW RD
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\C\CORRAL HOLLOW\18600\PR0231543\COMPLIANCE INFO.PDF
QuestysFileName
COMPLIANCE INFO
QuestysRecordDate
11/5/2012 8:00:00 AM
QuestysRecordID
121240
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
78
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MONITORING ALTERNATIVE 6 <br /> Implementation of this monitoring alternative will require <br /> Daily Inventory Reconciliation, Annual Tank Integrity <br /> Testing, Pipeline Leak Detection, Vadose Zone or Ground Water <br /> Monitoring Wells, and Soil Testing. If this monitoring <br /> alternative is chosen, implementation should be carried out <br /> as follows: <br /> 1) Perform the initial tank integrity test/tests to confirm that <br /> the tank/tanks do/does not leak at the time of implementation <br /> of the monitoring alternative. Integrity testing must be <br /> done within one year prior to implementation of the <br /> monitoring alternative. Based on information obtained from <br /> facility personnel all/the tanks/tank at this facility have <br /> passed an integrity test within the last year. <br /> Vadose Zone Wells <br /> 2a) Undisturbed soil samples shall be taken from the soil <br /> immediately surrounding each/the tank. The boring/borings <br /> shall be drilled to a depth of 40 feet and undisturbed soil <br /> samples shall be taken at 5 foot intervals with the last <br /> sample obtained from the base of the borings. All samples <br /> shall be properly sealed, labeled and preserved until they <br /> are delivered to a location where they can be analyzed to <br /> determine the presence of any possible hazardous substances <br /> that are present. Soil sampling and testing shall be carried <br /> out as specified in Section 2645 of the Underground Storage <br /> Tank Regulations. <br /> 3a) If the soil samples obtained are determined to be free of <br /> hazardous material a vadose zone monitoring well shall be <br /> installed in the vacated boring/borings. Vadose zone <br /> monitoring wells shall be designed and installed as specified <br /> in Sections 2646 and 2648 of the Underground Storage Tank <br /> Regulations. Vadose zone testing shall be performed <br /> semi-annually, at a minimum. Three types of vadose zone leak <br /> detectors, each of which would be acceptable for use at this <br /> site are attached at the end of the package. <br /> 4a) Implementation of this monitoring alternative will require <br /> annual calibration of flow meters by the State of California <br /> Bureau of Weights and Measures. <br />
The URL can be used to link to this page
Your browser does not support the video tag.