D. Alternate constrw%awon for new underground storage tanks containine,/otor vehicles fuel [Section 26331. <br /> N/A (1) Monitoring and response plan [Section 26341. <br /> (2) underground storage tank composed of.... <br /> (a) Fiberglass reinforced plastic. <br /> (b) Cathodically protected steel. <br /> (c) Steel clad with fiberglass reinforced plastic. <br /> (d) other material that complies with section 2631 and 2632. <br /> (3) Floor of leak interception and detection system constructed on a firm base and sloped to a <br /> collection sump (use of membrane liners comply with section 2631 (d) (6) requirements.) <br /> (4) Access casings installed in the collection sump of the secondary containment system with <br /> backfill in the interstitial space. The access casing shall meet all of the following: <br /> Designed and installed to allow the liquid to flow into the casing. <br /> — Sized to allow removal of collected liquid and able to withstand all anticipated applied <br /> stresses. <br /> constructed of material that will not be structurally weakened. <br /> Screened along entire vertical zone of permeable material. <br /> Capable of preventing leakage of any hazardous substance from the casing. <br /> Extend to the ground surface and covered with a locked waterproof cap. <br /> Capable of meeting S.J. Co. PMS-END well Standards. <br /> Leak interception and detection system shall prevent the leaked hazardous substance frog <br /> entering ground water. <br /> 14, INTERSTITIAL SPACE MONITORING <br /> A. Visual monitoring [Section 2632 (W (i)) N/A <br /> (a) Exterior surface and floor beneath tank monitored by direct viewing <br /> (b) Daily visual inspections <br /> (c) Liquid level in tank to be recorded at Time of inspection <br /> (d) If liquid observed around or beneath primary tank, owner will determine if an unauthorized release <br /> has occurred, <br /> B. Mechanical or electronic monitoring (Section 2632 (c) (2)1 <br /> (a) Continuous monitoring system connected to an audible and visual alarm system. <br /> monitoring equipment to be installed <br /> X Manufacturer: VEEDER ROOT <br /> X Model Number: TLS-350 <br /> X Sensor Type: __, Vapor (_ Liquid __ Both. <br /> Sensor/Panel specifications. (SEE ATTACHED EQUIPMENT LIST) <br /> _ Location(s) for sensors: <br /> Piping:TURRTNR SUMES <br /> Dispenser: DISPENSER SUMPS <br /> C. Monitoring and response plan submitted (section 2632 (d) (1) & (2)). <br /> is, Any special accessories, fittings, coatings, or linings not inherent within the initial design of the 10 tank or <br /> j, double-wall UST, [Section 2631 (b)) <br /> A. Approved by a nationally recognized independent testing organization. <br /> R. Demonstration of integrity with the primary andlor secondary containment. <br /> 6 <br />