Laserfiche WebLink
0 <br />D. Results of Testing/ Servicing <br />Software Version Installed: 327.04 <br />Complete the following checklist: <br />10 RECEIVE[ <br />FEB 2 0 2015 <br />ENWRONMENTAt <br />14Wrur1CDhO"r4ocpt7 <br />Yes <br />r No* <br />is the audible alarm operational? <br />is Yes <br />r No* <br />Is the visual alarm operational? <br />r Yes <br />r No* <br />Were all sensors visually inspected, functionally tested, and confirmed operational? <br />• Yes <br />r No* <br />Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will not interfere wit <br />heir proper operation? <br />• Yes <br />r No* <br />f alarms are relayed to a remote monitoring station, is all communications equipment (e.g. modem) operational? <br />r NIA <br />i« Yes <br />C" No*For <br />pressurized piping systems, does the turbine automatically shut down if the piping secondary containment monitoring <br />ystem detects a leak, fails to operate, or is electrically disconnected? If yes: which sensors initiate positive shut -down? (Check <br />r N/A <br />",that apply Sump/Trench Sensors; r Dispenser Containment Sensors. <br />Did you confirm positive shut -down due to leaks and sensor failureldisconnection70 Yes; r No <br />f Yes <br />r No* <br />otank systems that utilize the monitoring system as the primary tank overfill warning device (i,e. no mechanical overfill <br />[pll'!ovention valve is installed), is the overfill warning alarm visible and audible at the tank fill point(s) and operating properly? If <br />11 N/A <br />at what percent of tank capacity does the alarm trigger? % <br />is Yes` <br />r No <br />Was any monitoring equipment replaced? If yes, identify spec&c sensors, probes, or other equipment replaced and list the <br />anufaeturer name and model for all replacement parts in Section E below. <br />* Yes* <br />fie Na <br />Was liquid found inside any secondary containment systems designed as dry systems? (Check all that apply) <br />Product; I— Water. If yes, describe causes in Section E below. <br />fZ Yes <br />r No* <br />Was monitoring system set-up reviewed to ensure proper settings? Attach set up reports, if applicable <br />is Yes <br />r No* <br />Is all monitoring equipment operational per manufacturer's specifications? <br />* In Section E below, describe how and when these deficiencies were or will be corrected. <br />v.r. battery replaced. syphon jet valve replaced. all passed. <br />Monitoring System Certification Page 2 of 3 12/07 <br />