My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2011 - 2016
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
COLONY
>
1442
>
2300 - Underground Storage Tank Program
>
PR0518458
>
COMPLIANCE INFO 2011 - 2016
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/16/2022 11:14:22 AM
Creation date
11/2/2018 7:18:02 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2011 - 2016
RECORD_ID
PR0518458
PE
2361
FACILITY_ID
FA0013918
FACILITY_NAME
CHEVRON STATION #210997*
STREET_NUMBER
1442
STREET_NAME
COLONY
STREET_TYPE
Dr
City
RIPON
Zip
95336
APN
26102028
CURRENT_STATUS
01
SITE_LOCATION
1442 Colony Dr
P_LOCATION
05
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\IAError\C\COLONY\1442\PR0518458\COMPLIANCE INFO 2011 - 2016.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
547
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 10 <br />Page 6 of 9 <br />7 1TlVn R_n1CPF.NgRR CONTAINMENT (UDCI TESTING <br />Test Method Developed By: ❑ UDC Manufacturer Industry Standard ❑ Professional Engineer <br />❑ Other (Spec ) <br />Test Method Used: ❑ Pressure ❑ Vacuum Hydrostatic <br />❑ Other (Spec) <br />Test Fquipment Used: See attached testing procedures. Equipment Resolution: <br />UDC#1/2 UDC#314 UDC#516 UDC#7/8 <br />UDC Manuiaca;er: <br />UDC Material: <br />Fiberglass <br />Fiberglass <br />Fiberglass <br />Fiberglass <br />UDC Depth: <br />30" <br />30" <br />30" <br />30" <br />Height from UDC Bottom to Top <br />8" <br />8" <br />8" <br />8" <br />of Highest Piping Penetration: <br />Height from UDC Bottom to <br />4" <br />4" <br />4" <br />4" <br />Lowest Electrical Penetration: <br />Condition of UDC prior to <br />Fair <br />Fair <br />Fair <br />Fair <br />testing: <br />Portion of UDC Tested <br />Above highest <br />penetration <br />Above highest <br />penetratioR <br />Above high es�t <br />penetration <br />Above highest <br />penetration <br />I <br />Does turbine shut down when <br />UDC sensor detects liquid (both <br />❑ Yes ❑ No ®NA <br />❑Yes ❑ No 0 NA <br />El Yes ❑ No N NA <br />El Yes ❑ No ® NA <br />product and water)?` <br />Turbine shutdown response time <br />Is system programmed for fail- <br />❑ Yes ElNo ® 1 <br />qA <br />❑Yes 7No Ej NA <br />El ElNo ® NA <br />❑ Yes ❑ No Z NA <br />safe shutdown.?` <br />Was fail-safe verified to be <br />- <br />❑Yes ❑ No � <br />❑Yes ED No ®NA <br />El Yes El NO 9 NA <br />El Yes ❑ No ®NA <br />operational?* <br />Wait time between applying <br />pressure/vacuum/water and <br />30 minutes <br />30 minutes <br />30 minutes <br />30 minutes <br />starting test <br />Test Start Time: <br />12:04pm <br />12:04pm <br />1:52pm <br />2:16pm <br />! Initial Reading N: <br />1.6096 <br />2.4075 <br />11985 <br />1.6307 <br />Test End Time: <br />12:19pm <br />12-19pm <br />2:07pm <br />2:31pm <br />Final Reading (RF): <br />1.6108 <br />2.4073 <br />11985 <br />1.6307 <br />Test Duration: <br />15 min <br />15 min <br />15 Bain <br />IS nun <br />Change in Reading (RF -R[): <br />F11.00125 <br />0.00021 <br />0.00005 <br />0 <br />Pass/Fail Threshold. or Criteria: <br />0.002 <br />0.002 <br />0.002 <br />1 0.002 <br />Test Result: `: <br />:Pass . El Fail <br />MPass [ Fait <br />0 ,Pass ❑Fail <br />pass ❑ )Fail <br />Was sensor removed for testing? <br />[KYes ❑No ❑ NA <br />NYes ❑No ❑NA <br />®Yes El No ❑ NA <br />®Yes ❑No ❑ NA <br />Was sensor properly replaced and <br />®yes ❑No ❑ NA <br />EYes ❑No ❑NA <br />Oyes ❑No ❑ NA <br />®Yes ❑No ❑ NA <br />verified functional after testing? <br />Comments — (inelude information on repairs made prior to testing, and recomrnended follow-up for failed tests) <br />1 if the entire depth of the UDC is not tested, specify how much was tested. If the answer to any of the questions indicated with an <br />asterisk (*) is "NO" or "NA", the entire UDC must be tested. (See SWRCB LG -160) <br />
The URL can be used to link to this page
Your browser does not support the video tag.