• 0 <br />Page 8 of 9 <br />8. FTLL RISER CONTENT SUMP TESTING <br />Facility is Not Equipped With Fill Riser Containment Sumps ❑ <br />Fill Riser Containment Sumps are Present, but were Not Tested ❑ <br />Test Method Developed By: ❑ Sump Manufacturer ® Industry Standard [] Professional Engineer <br />❑ Other (SpedA) <br />Test Method Used: ❑ Pressure ❑ Vacuum Z Hydrostatic <br />❑ Other (Specify) <br />Test Equipment Used: See attached testing procedures <br />Equipment Resolution: <br />_ <br />Fill Sum p #8 7 <br />Fill Sump # 91 <br />Fill Sump # <br />Fill Sump_- # <br />Sump Diameter: <br />48" <br />48" <br />Sump Depth: <br />68" <br />70" <br />Height from Tank Top to Top of <br />Highest Piping Penetration: <br />12" <br />12" <br />Height from Taub Top to Lowest <br />Electrical Penetration: <br />20" <br />21" <br />Condition of sump prior to <br />testing:. <br />Fair <br />Fair <br />Portion of Sump Tested <br />Above highest <br />penetration <br />Above highest <br />penetration <br />Above highest <br />penetration <br />Above highest <br />penetration <br />Sump Material & Manufacturer: <br />Fiberglass <br />Fiber ass <br />Wait time between applying <br />pressure/vacuum/watcr and <br />starting test: <br />30 minutes) <br />30 minutes <br />30 minutes <br />30 minutes <br />`fest Start Time: <br />10:27am <br />11:12am <br />Initial Reading (Rt): <br />1.5833 <br />0.1474 <br />Test End Time: <br />10:42am <br />11:28am <br />Final Reading (RF): <br />1.5828 <br />0.1468 <br />f Test Duration: <br />15 min <br />15 niin <br />15 min <br />15 min <br />Change in Reading (RF-Rj): <br />0.00051 <br />0.00054 <br />_ - -- <br />Pass/Fail Threshold or Cziteria: <br />0.002 1 <br />0.002 <br />0.002 <br />0.002 <br />'.fest kesult: <br />® Pass ❑ Fail <br />Pass❑ Fail <br />, ❑ Pass ❑Fail _. <br />:;[] .Pass Fail <br />Is there a sensor in the sump? <br />® Yes ❑ No <br />® Yes ❑ No <br />❑ Yes ❑ No <br />EK Yes ❑ No <br />Does the sensor alarm when <br />either product or water is <br />detected? <br />MYes ❑ No [ENA <br />®Yes [-]No NNA <br />OYes ❑ No ❑NA <br />NYe5 ❑ No ❑NA <br />Was sensor removed for testing?NYes <br />E] Na RNA <br />®Ycs ❑ No❑NA <br />El No El <br />NA <br />®Yes ❑ No El <br />NA <br />Was sensor properly replaced and <br />verified functional after testing? <br />zY� ❑ No [:INA <br />Yes [:1No ❑NA <br />❑Ycs ❑ No ❑NA <br />Yes ❑ No ❑NA <br />Comments — (include information on repairs »rade prior to testing, and recommended follow-up for failed tests) <br />