My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2011 - 2016
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
COLONY
>
1442
>
2300 - Underground Storage Tank Program
>
PR0518458
>
COMPLIANCE INFO 2011 - 2016
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/16/2022 11:14:22 AM
Creation date
11/2/2018 7:18:02 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2011 - 2016
RECORD_ID
PR0518458
PE
2361
FACILITY_ID
FA0013918
FACILITY_NAME
CHEVRON STATION #210997*
STREET_NUMBER
1442
STREET_NAME
COLONY
STREET_TYPE
Dr
City
RIPON
Zip
95336
APN
26102028
CURRENT_STATUS
01
SITE_LOCATION
1442 Colony Dr
P_LOCATION
05
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\IAError\C\COLONY\1442\PR0518458\COMPLIANCE INFO 2011 - 2016.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
547
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FILL RISER CONTAINMENT SUMP TESTING <br />RECD J U L 20 2015 <br />Facility is Not Equipped With Fill Riser Containment Sumps ❑ <br />Fill Riser Containment Sumps are Present, but were Not Tested El <br />Test Method Developed By: ❑ Sump Manufacturer p Industn Standard ❑ Professional Engineer <br />❑ Other (Specify) <br />Test Method Used: ❑ Pressure ❑ Vacuum m Hydrostatic <br />❑ Other (Specify) <br />Test Equipment Used: See attached testing procedures Equipment Resolution: Inches <br />Fill Sump # 87 <br />Fill Sump;4 91 <br />Fill Sump # <br />Fill Sump # <br />Sump Diameter: <br />48" <br />48" <br />Sump Depth: <br />69" <br />69" <br />Height from Tank Top to Top of <br />Highest Piping Penetration: <br />1a <br />14 <br />Height from Tank Top to Lowest <br />Electrical Penetration: <br />z5 <br />25 <br />Condition of sump prior to <br />testing: <br />Fair <br />Fair <br />Fair <br />Fair <br />Portion of Sump Tested <br />Above highest penetration <br />Above highest penetration <br />Above highest penetration <br />Above highest penetration <br />Sump Material: <br />Fiberglass <br />Fiberglass <br />Wait time between applying <br />pressure/vacuum/water and <br />starting test: <br />15 minutes <br />15 minutes <br />15 minutes <br />15 minutes <br />Test Start Time: <br />10:52am <br />10:52am <br />Initial Reading (R,): <br />3.97772 Inches <br />3.85206 Inches <br />Inches <br />Inches <br />Test End Time: <br />11:07am <br />11:07am <br />Final Reading (RF): <br />3.97826 Inches <br />3.85270 Inches <br />Inches <br />Inches <br />Test Duration: <br />15 mins <br />15 mins <br />15 mins <br />15 mins <br />Change in Readin (RF -R,): <br />0.00()54 <br />0.00064 <br />Pass/Fail Threshold or Criteria: <br />.002 <br />.002 <br />Test Result: <br />p Pass ❑ Fail <br />p Pass ❑ Fail <br />❑ Pass ❑ Fail <br />❑ Pass ❑ Fail <br />Is there a sensor in the sump? <br />p Yes ❑ No <br />® Yes ❑ No <br />❑ Yes ❑ No <br />❑ Yes ❑ No <br />Does the sensor alarm when <br />either product or water is <br />detected? <br />Z Yes ❑ No ❑ NA <br />F] Yes ❑ No ❑ NA <br />❑ Yes ❑ No ❑ NA <br />❑ Yes ❑ No ❑ NA <br />Was sensor removed for testing? <br />® Yes ❑ No ❑ NA <br />❑ Yes ❑ No ❑NA <br />❑ Yes El No El NA <br />❑ Yes El No ❑ NA <br />Was sensor properly replaced and <br />verified functional after testing? <br />© Yes El No ❑ NA <br />p Yes ❑ No El NA <br />❑ Yes ❑ No ❑ NA <br />❑ Yes ❑ No ❑ NA <br />Comments — (include information on repairs made, rior to testin)z, and recommended follow-up for failed tests) <br />