My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2001 - 2009
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CORONADO
>
3807
>
2300 - Underground Storage Tank Program
>
PR0231066
>
COMPLIANCE INFO 2001 - 2009
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/1/2020 11:52:22 AM
Creation date
11/2/2018 7:33:47 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2001 - 2009
RECORD_ID
PR0231066
PE
2361
FACILITY_ID
FA0003819
FACILITY_NAME
Sprint United Managemnt Co.
STREET_NUMBER
3807
STREET_NAME
CORONADO
STREET_TYPE
Ave
City
Stockton
Zip
95204
CURRENT_STATUS
01
SITE_LOCATION
3807 Coronado Ave
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\IAError\C\CORONADO\3807\PR0231066\COMPLIANCE INFO 2001 - 2009.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
439
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB January,2002 Page of <br /> 7. UNDER-DISPENSER CONTAINMENT (UDC) TESTING Job#: T7029132 <br /> Test Method Developed By: QUDC Manufacturer ❑ Industn.Standard ❑ Professional Engineer <br /> g0dicr(Specify%) <br /> Test Method Used: —0—Pressure KqVacuu m g Hydrostatic <br /> QOther(.'�)ecifil <br /> Test Equipment Used: Equipment Resolution: <br /> une# - uD�c# unc# Li unt�# <br /> UDC Manufacturer: <br /> UDC Material: <br /> UDC Depth: <br /> Height from UDC Bottom to Top <br /> of Highest Piping Penetration: <br /> Height from UDC Bottom to - <br /> Lowest Electrical Penetration: <br /> Condition of UDC prior to <br /> testing: <br /> Portion of UDC Tested <br /> Does turbine shut down-when <br /> UDC <br /> -- - <br /> UDC sensor detects liquid (both ❑ Yes ❑ No ❑ NA ❑Yes ❑ No ❑ NA ❑ Yes ® No ❑ NA ❑Yes ❑ No ❑ NA <br /> product and crater)?' <br /> Turbine shutdown response time <br /> Is system progranunned for fail- <br /> safe shutdown?* ❑Yes ❑ No ❑ NA ❑Yes ❑ No ❑ NA ❑ Yes ❑ No ❑ NA ❑Yes ❑ No ❑ NA <br /> Was fail-safe verified to be <br /> operational? ❑Yes [INo [INA ❑Yes ElNo ❑ NA ElYes ElNo ElNA ElYes ❑ No ElNA <br /> ' <br /> Wait time between applying - <br /> pressurehncuunVwater and <br /> starting test <br /> Test Start Time: <br /> Initial Reading(RI).- <br /> Test <br /> RI):Test End Time: <br /> Final Reading(RF): <br /> Test Durations: <br /> Change in Reading(RF-RI): <br /> Pass/Fail Threshold or Criteria: <br /> Test Result: ❑Pass ❑Fail ❑Pass ❑Fail ❑Pass C]Fail ❑ Pass ❑Fail <br /> Was sensor removed for testing? Q Yes ❑ No ❑ NA ❑Yes_ ❑ No ❑ NA ❑Yes ❑No ❑NA ❑Yes ❑No ❑NA <br /> Was sensor property replaced and <br /> verified functional after testing? ❑Yes ❑No ❑ NA ❑Yes ❑ No ❑ NA FLOI Yes ❑No ❑NA ❑Yes ❑No ❑ NA <br /> Comments—(hichlde information on repairs made prior to testh1 q, and rete)iilliieiicled,li)llc)ii--ilpJ for failed tests) <br /> NIA <br /> If the entire depth of the UDC is not tested_specify hon-much was tested. If the answer to anv of the questions indicated with an asterisk <br /> M is"NO"or--NA',the entire UDC must be tested. (See SWRCB LG-160) <br />
The URL can be used to link to this page
Your browser does not support the video tag.