My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2001 - 2009
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CORONADO
>
3807
>
2300 - Underground Storage Tank Program
>
PR0231066
>
COMPLIANCE INFO 2001 - 2009
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/1/2020 11:52:22 AM
Creation date
11/2/2018 7:33:47 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2001 - 2009
RECORD_ID
PR0231066
PE
2361
FACILITY_ID
FA0003819
FACILITY_NAME
Sprint United Managemnt Co.
STREET_NUMBER
3807
STREET_NAME
CORONADO
STREET_TYPE
Ave
City
Stockton
Zip
95204
CURRENT_STATUS
01
SITE_LOCATION
3807 Coronado Ave
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\IAError\C\CORONADO\3807\PR0231066\COMPLIANCE INFO 2001 - 2009.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
439
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
. i,.,esuits of Testing/Servicing <br /> Sofn�:sre Version lnstailed: <br /> Comoleic the following checklist: <br /> � 1°e; ❑ No* Is the audible alarm operational? <br /> .es ❑ No* Is the visual alarm o erational? <br /> [t* Y1--s ❑ No* Were all sensors visually inspected, fi=tionakl tested, and confirmed operational? <br /> ❑ No* Were all sensors installed at lowest point of secondary containment and positioned so that other equipment <br /> not interfere with their proper operation? <br /> �'t-s PU NO If alarms are relayed to a remote monitoring station, is all conuntrnications equipment (e.g. muciem) <br /> ❑ NIA operational? <br /> U 1'5 ❑ No* For pressurized piping systems, does the turbine automatically shut down if the piping secondary coalainnleIq <br /> LZ N/A monitoring system detects a leak, fails to operate, or is electrically disconnected? if yes: which sensors irti:i., ti <br /> positive shut-down? (Check till rhtat apply) ❑ Suntp/Trench Sensors; ❑ Dispenser Contasnmenr Sensors. <br /> Did You confii-►n ROSiLive shut-down due to leaks sensor failure/disconnection? ❑ Yes; ❑ No. _ <br /> U 1 es ❑ No* For rank- systerns that utilize the trionitorinc, system as the primary tank overfill warning device (i.e. rto <br /> N/A mechanical overfill prevention valve is installed), is the overfill warning alarm visible and audible at the m I l•. <br /> till oint(s) and operating properly? if so, at what percent of tan.lc capacity does the alarm tri ger? <br /> LU `tcs� No Was any monitoring equipment replaced? If yes, identify specific sensors, probes, or other equipment repl:ICCL! <br /> and Jist the manufacturer name and model for all re lacemenr 2aris in Section E, below. <br /> iV les°^ No Was liquid found inside any secondary containment systems designed as dry systems? (Check all rhar app,),, J <br /> _ Pr•oducr; ❑ Water, If yes, describe causes in Section E, below. _ <br /> Y'cs l7 No* Was monitoring system ser-Lip reviewed to ensure proper settings? Attach set LIP reports, if applicable <br /> _Y ❑ No* is all monitoring equip-mem o erationa3 per n3anufacti'irer's specifications? <br /> lr, Secriun E below, describe how and when these deficiencies were or will be corrected. <br /> L. Comments: <br /> page 2 of 3 0.; 0 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.