3807
>
2300 - Underground Storage Tank Program
>
PR0231066
>
COMPLIANCE INFO 2001 - 2009
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/1/2020 11:52:22 AM
Creation date
11/2/2018 7:33:47 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2001 - 2009
RECORD_ID
PR0231066
PE
2361
FACILITY_ID
FA0003819
FACILITY_NAME
Sprint United Managemnt Co.
STREET_NUMBER
3807
STREET_NAME
CORONADO
STREET_TYPE
Ave
City
Stockton
Zip
95204
CURRENT_STATUS
01
SITE_LOCATION
3807 Coronado Ave
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\IAError\C\CORONADO\3807\PR0231066\COMPLIANCE INFO 2001 - 2009.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
439
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB.J:anuaiy 2002 Page of <br /> 6. PIPING SUMP TESTING <br /> Test Method Developed By.- ❑ Sump Manufacturer � Industi3- Standard x Professional Engineer j <br /> ❑Other(Specify) <br /> Test Method Used: ❑Pressure ❑Vacuum x Hydrostatic <br /> ❑ Other(Specify) <br /> Test Equipment Used: :TS-STS icon sump test System Equipment Resolution: 2.101 <br /> - — - Sump#Tank Sump# Sump# Svmp# <br /> Sump Diameter: 4g" �2" <br /> Sump Depth. 42" �2++ <br /> Sump Material: Fiberglass Fiberglass <br /> Height from Tank Top to Top of 1219 7" <br /> Highest Piping Penetration: <br /> Height from Tank Top to Lowest 7" 6" <br /> Electrical Penetration: <br /> Condition of sump prior to testing: Clean Clean <br /> Portion of Sump Tested` 14" <br /> Does turbine shut down when <br /> sump sensor detects liquid(both ❑Yes ❑No ■NA ❑Yes D No E NA ❑Yes ❑No ❑NA ❑Yca ❑No LIMA <br /> -product and water)?* <br /> Turbine shutdown response time NIA NIA <br /> Is system programmed for fail-safe <br /> -shutdown"* ❑Yes 11No ■NA ❑Yes ❑No ■NA ❑Yes ❑No El NA Yes ❑No ❑NA <br /> Was fail-safe verified to be ❑Yes ❑No ■NA ❑Yes ❑No ■NA D Yes ❑No ❑N 1 ❑Yes 0 No C NA <br /> operational?* <br /> Wait time between applying <br /> pressure/vacuum/water and starting 15 min 15 min 15 min 15 min <br /> test: <br /> Test Start Time: 10:56 14:33 <br /> Initial Reading(Rj): 7.7379 7.0108 <br /> Test End Time: 11:11 14:48 <br /> Final Reading(RF): 7.7377 7.0119 <br /> Test Duration: 15 min 13 min 15 min 15 min <br /> Change in Reading (RF-RO: .0002 .0008 <br /> Pass/Fail Threshold or Criteria: .002 .002 ,002 .002 <br /> "Test Result: ■ Pass ❑Fail ■ Pass ❑Fail ❑ Pass []Fail ❑ Pass ❑Fail <br /> Was sensor removed for testing? ■ Yes ❑No ❑NA ■Yes ❑No ❑NA ❑Yes ❑No O NA ❑Yes ❑No ❑NA <br /> Was sensor properly replaced and M Yes ❑No ❑NA ■Yc s a No ❑NA ❑Yes --No ❑NA 0 Ycs [INo ❑NA <br /> verified ftinctional after testing'? <br /> Comm err is— (include information on repairs made prior to testing, and recommended follow•-up for failed tests) <br /> If the entire depth of the sump is not tested,speci4 bow much was tested. If the answer to any of the questions indicated with an <br /> asterisk (*)is"NO"or--NA",the entire sump trust be tested. (See SWRCB LG-160) <br />
The URL can be used to link to this page
Your browser does not support the video tag.