My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2001 - 2009
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CORONADO
>
3807
>
2300 - Underground Storage Tank Program
>
PR0231066
>
COMPLIANCE INFO 2001 - 2009
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/1/2020 11:52:22 AM
Creation date
11/2/2018 7:33:47 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2001 - 2009
RECORD_ID
PR0231066
PE
2361
FACILITY_ID
FA0003819
FACILITY_NAME
Sprint United Managemnt Co.
STREET_NUMBER
3807
STREET_NAME
CORONADO
STREET_TYPE
Ave
City
Stockton
Zip
95204
CURRENT_STATUS
01
SITE_LOCATION
3807 Coronado Ave
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\IAError\C\CORONADO\3807\PR0231066\COMPLIANCE INFO 2001 - 2009.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
439
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB.January 2002 � � Page of <br /> T. UNDER-DISPENSER CONTAINMENT(UDC)TESTING <br /> Test Method Developed By: ❑UDC Manufacturer ❑Industry Standard x Professional Engineer <br /> ❑Other(Specify) <br /> Test Method Used: ❑Pressure ❑Vacuum x Hydrostatic <br /> ❑Other(Specify) <br /> Test Equipment Used: : TS-STS icon sumip test S)stem Equipment Resolution: 2.101 <br /> UDC#NONE UDC# UDC# UDC# <br /> LDC Manufacturer: N/A <br /> UDC Material: <br /> UDC Depth: 9 <br /> Height from UDC Bottom to Top <br /> of Highest Piping Penetration: <br /> Height from UDC Bottom to <br /> Lowest Electrical Penetration: <br /> Condition of UDC prior to <br /> testing: <br /> Portion of UDC Tested <br /> Does turbine shut down when <br /> UDC sensor detects liquid(both ❑Yea ❑No ❑NA ❑Yes ❑No ❑NA ❑Yes 0 No Q NA ❑Yes ❑No ❑NA <br /> product and water)"' <br /> Turbine shutdown response time <br /> Is system programmed for fail- ❑Yes ❑No ❑NA ❑Yes G No [INA ❑Yes t❑No ❑NA ❑Yes ❑No ❑NA <br /> safe shutdown?* <br /> Was fail-safe verified to be ❑Yes ❑No ❑NA ❑Yes ❑No ❑NA ❑Yes ❑No ❑NA ❑Yes ❑No ❑'NA <br /> o erational?i <br /> Wait time between applying 15 min 15 min 15 min 15 min j <br /> pressure/vacuum/water and <br /> starting test <br /> Test Start Time: <br /> Initial Reading (Rt): <br /> Test End Time: <br /> Final Reading(RF): <br /> TeA Duration: 15 min li Hain 1-min 15 min <br /> Change in Reading(RF-Rj): <br /> Pass/Fail Threshold or Criteria: .002 1 .002 .002 .002 <br /> Test Result: ❑ Pass ❑Fail ❑ Pass ❑Fail ❑ Pass ❑Fail ❑ Pass ❑Fail <br /> Was sensor removed for testing? ❑Yes ❑No ❑NA ❑Yes ❑No ❑NA ❑Yes El No ❑NA ❑Yes ❑No ❑NA <br /> Was sensor properly replaced and ❑Yes ❑No ❑NA ❑Yes ❑No ❑NA ❑Yes ❑No ❑NA ❑Yes ❑No :INA <br /> verified functional after testing? <br /> Comments— (include information on repairs made prior to testing, and recommended folloit-up forfailed tests) <br /> If the entire depth of the UDC is not tested, specify how much was tested. If the answer to My of the questions indicated with an <br /> asterisk(*)is"NO-'or"NA".the entire UDC must be tested. (See SWRCB LG-160) <br />