Laserfiche WebLink
10 <br />0 <br />San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, <br />Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: <br />(209) 468-3433 Web: MWL,s1 ov.or /ehd <br />Underground Storage Tank Program <br />Facility Name: <br />Inspection Report <br />Costco Wholesale #1031 Facility Address: <br />2440 Daniels ST, Manteca <br />Date: <br />August 18, 2016 <br />204 CCR 2712(1) <br />On Site Records <br />205 CCR 2712(i) <br />Current monitoring plan approved by the EHD not found on site <br />206 CCR 2712 <br />Failure to have an approved UST response plan available onsite <br />° V ° R o COS <br />207 HSC 25294 <br />Failure to comply with UST o eratin <br />p 9 permit conditions <br />° V ° R ❑COS <br />208 CCR 2650(e) <br />Failed to record unauthorized release from primary containment <br />OV ° R a COS <br />209 CCR 2715(c) <br />Failed to notify the EHD of a reportable unauthorized release <br />210 <br />Designated operator did not inspect all required items and/or the inspection <br />° V ° R LCOS <br />CCR 2715(e) <br />reports not completed <br />Designated operator monthly inspection <br />r V ° R ° COS <br />211 CCR 2715(f) <br />reports not maintained on site for at least 12 months <br />Designated operator employee <br />V ° R <br />212 CCR 2715(f)(2) <br />training not performed or log not kept <br />n COS <br />213 HSC 25281)O <br />( 5 b 2 <br />Unstaffed facility failed to have or implement a training° <br />program approved by the EHD <br />Unburied <br />V °R ❑ COS <br />214 HSC 25281.5(b){3) <br />fuel piping at marinas not visually inspected at least daily or log not kept <br />° V ° R ❑ COS <br />Unburied emergency generator fuelp� i m not visually inspected at least monthly <br />p 9 <br />D V ° R ° COS <br />or log kept <br />UST System Observations <br />° V Q R ° COS <br />301 HSC 25292.1 <br />UST system is not operated to <br />— <br />302 HSC 25291(b) <br />prevent unauthorized release, including spills and overfills <br />UST system incapable of detecting <br />° V ° R Li COS <br />303 HSC 25290.2(d) <br />leak from primary into secondary containment (pre -Jul 2003 <br />Monitoring system not maintained <br />11 V ° R ° COS <br />304 HSC 25290.1(d) <br />to detect entry into secondary containment (Jul 2003 -Jun 2004) <br />Monitoring system not maintained <br />° <br />305 HSC 25290.1(e) <br />to detect entry into secondary containment (after Jul 2004) <br />VPH monitoring of the interstitial <br />� V ° R ° S <br />306 CCR 2630(d) <br />spaces of the UST system is not maintained <br />Monitoring equipment is not installed <br />V ° R CS <br />or maintained to detect a leak at the earliest opportunity° <br />307 CCR 2632(c) <br />() <br />Monitoring system of the interstitial space of a double walled system not maintained <br />• V � R ■COS <br />308 CCR 2636(f) <br />Failed to maintain a continuous monitoring system that activates <br />° V ° R 17 COS <br />309 CCR 2636(f)(1) <br />an audible and visual alarm <br />Monitoring in sump / UDC failed to activate an audible and visual alarm <br />° V ° R ° COS <br />310 CCR 2636(f (5) <br />or stop the Flow product <br />Piping is not fail-safe outside UDCs or fails to stop flow of product at dispenser <br />° V ° R ° COS <br />311 CCR 2638(a), 26410) <br />inside UDCs <br />Failed to ro g p <br />property program or erste leak detection <br />° V ❑ R ❑COS <br />equipment <br />312 CCR 2fi 38[fy <br />Failed to affix a tag sticker an monitoring equipment certified, repaired, or replaced <br />° ti' ° R ❑COS <br />313 HSC 25290.1, 25290.2, <br />Failure to construct, operate, and maintain primary containment as product -tight <br />aV ❑R COS <br />❑ <br />25291 <br />o V ❑ R ° COS <br />314 HSC 25290.1, 25290.2, <br />Failed to have secondary containment or secondary containment not tight <br />25291 <br />° V ° R ° COS <br />315 r1sC 25291(e) <br />Water in secondary containment not removed, analyzed, and properly disposed of (pre -Jul 2003) <br />316 HSC 25290.1(c3), <br />25290.2- <br />Secondary containment not constructed to prevent water intrusion (after Jul 2003) <br />❑ V ❑ R ❑COS <br />■ V ° R ■ COS <br />317 CCR 2636(f)(2) <br />Line leak detector not installed <br />318 CCR 2636(f)(2) <br />itsO <br />Leak detector failed to detect a 3.0 gph leak at 10 psi <br />° V ❑ R o COS <br />319 CCR 2635(b) <br />No spill bucket, failed to contain five gallons, or failed to provide a means to keepit empty <br />0 ❑R ■COS <br />320 CCR 2635(b)(2) <br />Overfill prevention system not present or failed to <br />° V ❑ R °COS <br />321 CCR 2635(b)(2) <br />( )(2) <br />meet overfill requirements <br />OverFll prevention was overridden <br />0V °R u COS <br />nV o ❑COS <br />Page 2 of 6 <br />