My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2007-2012
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
D
>
DR MARTIN LUTHER KING JR
>
508
>
2300 - Underground Storage Tank Program
>
PR0231057
>
COMPLIANCE INFO 2007-2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/6/2020 4:40:12 PM
Creation date
11/4/2018 3:09:36 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2007-2012
RECORD_ID
PR0231057
PE
2361
FACILITY_ID
FA0003720
FACILITY_NAME
CHARTER WAY PETRO INC.
STREET_NUMBER
508
Direction
W
STREET_NAME
DR MARTIN LUTHER KING JR
STREET_TYPE
BLVD
City
STOCKTON
Zip
95206
APN
16504016
CURRENT_STATUS
01
SITE_LOCATION
508 W DR MARTIN LUTHER KING JR BLVD
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\D\DR MARTIN LUTHER KING JR\508\PR0231057\COMPLIANCE INFO 2007-2012.PDF
QuestysFileName
COMPLIANCE INFO 2007-2012
QuestysRecordDate
2/15/2018 12:34:40 AM
QuestysRecordID
3795241
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
373
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Monitoring System Certification en <br /> ��E <br /> D. Results of Testing/Servicing <br /> Software Version Installed: 18.01 <br /> Com fete the followina checklist: <br /> p Yes ILI <br /> No* is the audible alarm o erational? <br /> El Yes No* Is the visual alarm o erational? <br /> El Yes No* Were all sensors visual) ins ected, functional) tested,and confirmed operational? <br /> El Yes ❑ No* Were all sensors installed at lowest point of secondary containment and positioned so that other;7,nt <br /> not interfere with their proper operation? <br /> rYes ❑ No* If alarms are relayed to a remote monitoring station, is all communications equipment (e.g. modem) <br /> M NIA operational? <br /> ❑ No* For pressurized piping systems, does the turbine automatically shut down if the piping secondary containment <br /> ❑ N/A monitoring system detects a leak,fails to operate,or is electrically disconnected? If yes: which sensors initiate <br /> positive shut-down? (Check all that apply) 0 Sump/Trench Sensors; ❑ Dispenser Containment Sensors. <br /> Did you confirm positive shut-down due to leaks and sensor failure/disconnection? 0 Yes; ❑No. <br /> ❑ No* For tank systems that utilize the monitoring system as the primary tank overfill warning device (i.e. no <br /> El NIA mechanical overfill prevention valve is installed), is the overfill warning alarm visible and audible at the tank <br /> fill oint s and o eratin ro erl ? If so,at what ercent of tank ca aci does the alarm tri er? %O No Was any monitoring equipment replaced? If yes, identify specific sensors,probes,or other equipment replaced <br /> and list the manufacturer name and model for all replacement parts in Section E,below. <br /> ❑Yes* N No Was liquid found inside any secondary containment systems designed as dry systems? (Check all that apply) <br /> ❑ Product; ❑ Water. if yes,describe causes in Section E,below. <br /> D Yes ❑ No* Was monitoring system set-up reviewed to ensure ro er settings?Attach set up reports,if applicable <br /> E Yes ❑ No* Is all monitoring equipment oerational per manufacturer's specifications? <br /> *In Section E below,describe how and when these deficiencies were or will be corrected. <br /> E. Comments: Dispenser 5-6 had a bad float on the 87. <br /> Elite IV changed the float. Now operating normal. <br /> I changed the programming to disable in-tank leak testing, by owner's request. <br /> LIN-036-214 Page 2 of 4 Rev.06/91/01 <br /> www.11illd Ocs.or" <br />
The URL can be used to link to this page
Your browser does not support the video tag.