Monitoring System Certification en <br /> ��E <br /> D. Results of Testing/Servicing <br /> Software Version Installed: 18.01 <br /> Com fete the followina checklist: <br /> p Yes ILI <br /> No* is the audible alarm o erational? <br /> El Yes No* Is the visual alarm o erational? <br /> El Yes No* Were all sensors visual) ins ected, functional) tested,and confirmed operational? <br /> El Yes ❑ No* Were all sensors installed at lowest point of secondary containment and positioned so that other;7,nt <br /> not interfere with their proper operation? <br /> rYes ❑ No* If alarms are relayed to a remote monitoring station, is all communications equipment (e.g. modem) <br /> M NIA operational? <br /> ❑ No* For pressurized piping systems, does the turbine automatically shut down if the piping secondary containment <br /> ❑ N/A monitoring system detects a leak,fails to operate,or is electrically disconnected? If yes: which sensors initiate <br /> positive shut-down? (Check all that apply) 0 Sump/Trench Sensors; ❑ Dispenser Containment Sensors. <br /> Did you confirm positive shut-down due to leaks and sensor failure/disconnection? 0 Yes; ❑No. <br /> ❑ No* For tank systems that utilize the monitoring system as the primary tank overfill warning device (i.e. no <br /> El NIA mechanical overfill prevention valve is installed), is the overfill warning alarm visible and audible at the tank <br /> fill oint s and o eratin ro erl ? If so,at what ercent of tank ca aci does the alarm tri er? %O No Was any monitoring equipment replaced? If yes, identify specific sensors,probes,or other equipment replaced <br /> and list the manufacturer name and model for all replacement parts in Section E,below. <br /> ❑Yes* N No Was liquid found inside any secondary containment systems designed as dry systems? (Check all that apply) <br /> ❑ Product; ❑ Water. if yes,describe causes in Section E,below. <br /> D Yes ❑ No* Was monitoring system set-up reviewed to ensure ro er settings?Attach set up reports,if applicable <br /> E Yes ❑ No* Is all monitoring equipment oerational per manufacturer's specifications? <br /> *In Section E below,describe how and when these deficiencies were or will be corrected. <br /> E. Comments: Dispenser 5-6 had a bad float on the 87. <br /> Elite IV changed the float. Now operating normal. <br /> I changed the programming to disable in-tank leak testing, by owner's request. <br /> LIN-036-214 Page 2 of 4 Rev.06/91/01 <br /> www.11illd Ocs.or" <br />