Laserfiche WebLink
02/10/2011 THU 08:22 FAX 2094683433 SJC EHD 2001 <br /> is <br /> *** FAX TX REPORT *** <br /> TRANSMISSION OK <br /> JOB NO. 3944 <br /> DESTINATION ADDRESS 919169841117 <br /> PSWD/SUBADDRESS <br /> DESTINATION ID <br /> ST. TIME 02/10 08: 21 <br /> USAGE T 00' 41 <br /> PGS. 2 <br /> RESULT OK <br /> San Joaquin County <br /> Environmental Health Department DIRECTOR <br /> r.' 600 East Main Street Donna Heran,REHS <br /> in i•. .� <br /> PROGRAM COORDINATORS <br /> Stockton, California 95202-3029 <br /> Robert McClellan,REHS <br /> Jeff Carruesco,REHS,RDI <br /> • C9' .... Website:www.sjgov.org/ehd Kasey Foley,REHS <br /> � <br /> r F o R Linda Turkatte,REHS <br /> Phone: (209)468-3420 <br /> Fax: (209)464-0138 <br /> February 7, 2011 RECOPY <br /> NasirChoudry <br /> Infinity General Engineering Const. & Design ■1� <br /> 6716 Castro Verde Way <br /> Elk Grove, CA 95757 <br /> Re: SRH Food & Gas SR0056531, revised <br /> 749 E. Charter Way, Stockton <br /> The San Joaquin County Environmental Health Department(EHD) has completed the review of <br /> the application for a permit to replace the dispensers and install UDC conversion kits, convert <br /> the midgrade(89)tank to diesel, replace the existing wiring conduits at the ATGs, relocate and <br /> cold start the monitoring panel, and complete the EVR phase II upgrade and the ISD upgrade <br /> on the underground storage tank(UST)system at the above noted address. The revised scope <br /> of work may require breaking concrete over all three USTS. The permit has been approved with <br /> the following conditions: <br /> 1. Contact the local fire department and the San Joaquin Valley Air Pollution Control <br /> District for any applicable permits and requirements. <br /> 2. Any changes in information and scope of work must be submitted to EHD for approval <br /> prior to commencing work. All new addenda supersede the previous ones. <br /> 3. Contact Stacy Rivera at(209)468-3440 to arrange the following inspection <br /> appointments (a 48-hour notice is required for inspection appointments). Please be <br /> aware that inspections for emergency work must be scheduled within five days of permit <br /> approval. <br /> a. Sensor functionality: Functionality of the monitoring system must be verified to <br /> ensure that monitoring has been restored to meet the requirements of Title 23 <br /> California Code of Regulations and the Health &Safety Code. A copy of the alarm <br /> history shall be printed prior to performing the"cold start"of the Veeder Root system <br />