My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2004 - 2006
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
D
>
DUCK CREEK
>
3633
>
2300 - Underground Storage Tank Program
>
PR0232461
>
COMPLIANCE INFO 2004 - 2006
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/6/2020 4:40:07 PM
Creation date
11/4/2018 3:40:38 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2004 - 2006
RECORD_ID
PR0232461
PE
2361
FACILITY_ID
FA0003758
FACILITY_NAME
RYDER TRUCK RENTAL #1071
STREET_NUMBER
3633
STREET_NAME
DUCK CREEK
STREET_TYPE
DR
City
STOCKTON
Zip
95215
APN
17331001
CURRENT_STATUS
01
SITE_LOCATION
3633 DUCK CREEK DR
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\D\DUCK CREEK\3633\PR0232461\COMPLIANCE INFO 2004 - 2006.PDF
QuestysFileName
COMPLIANCE INFO 2004 - 2006
QuestysRecordDate
4/25/2018 10:46:56 PM
QuestysRecordID
3869444
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
155
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
' If the entire depth of the sump is not tested, specify how much was tested. If the answer to gpy of the questions indicated with an <br />asterisk (*) is "NO" or "NA", the entire sump must be tested. (See SWRCB LG -160) <br />Page of <br />SWRCB, January 2002 <br />12. PIPING SUMP TESTING <br />Test Method Developed By: <br />❑ Sump Manufacturer ❑ Industry Standard ❑ Professional Engineer <br />x Other (Spec) County Protocol <br />Test Method Used: <br />❑ Pressure ❑ Vacuum <br />X Hydrostatic <br />0 Other (Spec) <br />Test Equipment Used: Incon STS <br />Equipment Resolution: .002 <br />Sump #Oil Trans Sump 9 <br />Sump 4 Sump # <br />Sump Diameter: <br />35" <br />Sump Depth: <br />10.5" <br />Sump Material: <br />Fiberglass <br />Height from Tank Top to Top of <br />7" <br />Highest Piping Penetration: <br />Height from Tank Top to Lowest <br />7" <br />Electrical Penetration: <br />Condition of sump prior to testing: <br />Good <br />Portion of Sump Tested' <br />2" over piping <br />Does turbine shut down when <br />sump sensor detects liquid (both <br />❑Yes 11No x NA ❑ Yes ❑No DNA <br />❑ Yes F1 No ❑ NA F1Yes ❑ No xNA <br />product and water)?* <br />Turbine shutdown response time <br />seconds <br />Is system programmed for fail-safe <br />❑ Yes ❑ No x NA <br />❑ Yes ❑ No ❑ NA <br />❑ Yes ❑ No ❑ NA <br />❑ Yes ❑ No ❑ NA <br />shutdown?* <br />Was fail-safe verified to be <br />❑ Yes ❑ No x NA <br />❑ Yes ❑ No ❑ NA <br />❑ Yes ❑ No ❑ NA <br />❑ Yes ❑ No ❑ NA <br />operational?` <br />Wait time between applying <br />pressure/vacuum/water and starting <br />30 Minutes <br />test: <br />Test Start Time: <br />2:26 / 2:42 <br />Initial Reading (Rj): <br />2.8492 / 2.8493 <br />Test End Time: <br />2:41 / 2:57 <br />Final Reading (RF): <br />2.8491 / 2.8490 <br />Test Duration: <br />15 min ! 15 min <br />Change in Reading (RF-Ri): <br />.0000/.0003 <br />Pass/Fail Threshold or Criteria: <br />.002 <br />Test Result; <br />X Pass []Fail <br />❑ Pass D Fail <br />❑ Pass ❑ Fail <br />❑ Pass ❑ Fail <br />Was sensor removed for testing? <br />X Yes ❑ No [INA ❑ Yes ❑ No ❑ NA <br />❑ Yes ❑ No [INA ❑ Yes ❑ No ❑ NA <br />Was sensor properly replaced and <br />X Yes D No [INA ❑ Yes ❑ No ❑ NA <br />❑ Yes ❑ No ❑ NA ❑ Yes ❑ No ❑ NA <br />verified functional after testing? <br />Comments — (include information on repairs made prior to testing and recommended follow-up for failed tests) <br />' If the entire depth of the sump is not tested, specify how much was tested. If the answer to gpy of the questions indicated with an <br />asterisk (*) is "NO" or "NA", the entire sump must be tested. (See SWRCB LG -160) <br />
The URL can be used to link to this page
Your browser does not support the video tag.