Laserfiche WebLink
' If the entire depth of the sump is not tested, specify how much was tested. If the answer to gpy of the questions indicated with an <br />asterisk (*) is "NO" or "NA", the entire sump must be tested. (See SWRCB LG -160) <br />Page of <br />SWRCB, January 2002 <br />12. PIPING SUMP TESTING <br />Test Method Developed By: <br />❑ Sump Manufacturer ❑ Industry Standard ❑ Professional Engineer <br />x Other (Spec) County Protocol <br />Test Method Used: <br />❑ Pressure ❑ Vacuum <br />X Hydrostatic <br />0 Other (Spec) <br />Test Equipment Used: Incon STS <br />Equipment Resolution: .002 <br />Sump #Oil Trans Sump 9 <br />Sump 4 Sump # <br />Sump Diameter: <br />35" <br />Sump Depth: <br />10.5" <br />Sump Material: <br />Fiberglass <br />Height from Tank Top to Top of <br />7" <br />Highest Piping Penetration: <br />Height from Tank Top to Lowest <br />7" <br />Electrical Penetration: <br />Condition of sump prior to testing: <br />Good <br />Portion of Sump Tested' <br />2" over piping <br />Does turbine shut down when <br />sump sensor detects liquid (both <br />❑Yes 11No x NA ❑ Yes ❑No DNA <br />❑ Yes F1 No ❑ NA F1Yes ❑ No xNA <br />product and water)?* <br />Turbine shutdown response time <br />seconds <br />Is system programmed for fail-safe <br />❑ Yes ❑ No x NA <br />❑ Yes ❑ No ❑ NA <br />❑ Yes ❑ No ❑ NA <br />❑ Yes ❑ No ❑ NA <br />shutdown?* <br />Was fail-safe verified to be <br />❑ Yes ❑ No x NA <br />❑ Yes ❑ No ❑ NA <br />❑ Yes ❑ No ❑ NA <br />❑ Yes ❑ No ❑ NA <br />operational?` <br />Wait time between applying <br />pressure/vacuum/water and starting <br />30 Minutes <br />test: <br />Test Start Time: <br />2:26 / 2:42 <br />Initial Reading (Rj): <br />2.8492 / 2.8493 <br />Test End Time: <br />2:41 / 2:57 <br />Final Reading (RF): <br />2.8491 / 2.8490 <br />Test Duration: <br />15 min ! 15 min <br />Change in Reading (RF-Ri): <br />.0000/.0003 <br />Pass/Fail Threshold or Criteria: <br />.002 <br />Test Result; <br />X Pass []Fail <br />❑ Pass D Fail <br />❑ Pass ❑ Fail <br />❑ Pass ❑ Fail <br />Was sensor removed for testing? <br />X Yes ❑ No [INA ❑ Yes ❑ No ❑ NA <br />❑ Yes ❑ No [INA ❑ Yes ❑ No ❑ NA <br />Was sensor properly replaced and <br />X Yes D No [INA ❑ Yes ❑ No ❑ NA <br />❑ Yes ❑ No ❑ NA ❑ Yes ❑ No ❑ NA <br />verified functional after testing? <br />Comments — (include information on repairs made prior to testing and recommended follow-up for failed tests) <br />' If the entire depth of the sump is not tested, specify how much was tested. If the answer to gpy of the questions indicated with an <br />asterisk (*) is "NO" or "NA", the entire sump must be tested. (See SWRCB LG -160) <br />