My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2004 - 2006
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
D
>
DUCK CREEK
>
3633
>
2300 - Underground Storage Tank Program
>
PR0232461
>
COMPLIANCE INFO 2004 - 2006
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/6/2020 4:40:07 PM
Creation date
11/4/2018 3:40:38 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2004 - 2006
RECORD_ID
PR0232461
PE
2361
FACILITY_ID
FA0003758
FACILITY_NAME
RYDER TRUCK RENTAL #1071
STREET_NUMBER
3633
STREET_NAME
DUCK CREEK
STREET_TYPE
DR
City
STOCKTON
Zip
95215
APN
17331001
CURRENT_STATUS
01
SITE_LOCATION
3633 DUCK CREEK DR
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\D\DUCK CREEK\3633\PR0232461\COMPLIANCE INFO 2004 - 2006.PDF
QuestysFileName
COMPLIANCE INFO 2004 - 2006
QuestysRecordDate
4/25/2018 10:46:56 PM
QuestysRecordID
3869444
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
155
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 <br />0 <br />Page of <br />SWRCB, January 2002 <br />15, <br />FELL RISER CONTAINMENT SUMP TESTING <br />Facility is Not Equipped With Fill Riser Containment Sumps <br />LJ <br />Fill Riser Containment Sumps are Present, but were Not Tested ❑ <br />Test Method Developed By: <br />❑ Sump Manufacturer <br />❑ Industry Standard ❑ Professional Engineer <br />x Other (Spec) County Protocol <br />Test Method Used: <br />❑ Pressure <br />❑ Vacuum <br />X Hydrostatic <br />D Other (Spec) <br />Test Equipment Used: Incon STS <br />Equipment Resolution: .002 <br />Fill Sump #T-I <br />Fill Sump #T-2 <br />Fill Sump 4T-3 <br />Fill Sump #T-4 <br />Sump DiameterEnk <br />42„ <br />42„ <br />42" <br />Sum Depth: <br />76.5" <br />76" <br />39" <br />Height from Taap ofNIA <br />NIA <br />NIA <br />Ili hest Pi in :Height <br />from Taowest10.5" <br />g65 <br />10.5" <br />9"Electrical <br />PeneCondition <br />of suGood <br />Good <br />Good <br />testing: <br />Portion of Sump Tested <br />2" over collar <br />2" over collar <br />2" over collar <br />2" over collar <br />Sump Material: <br />Fiberglass <br />Fiberglass <br />Fiberglass <br />Fiberglass <br />Wait time between applying <br />30 minutes <br />30 minutes <br />30 minutes <br />30 minutes <br />pressure/vacuum/water and <br />startin test:: <br />Test Start Time: <br />11:10 / 11:27 <br />11:10 / 11:27 <br />12:36 / 12:54 <br />3:51 / 4:08 <br />Initial Reading (R,): <br />1.4527 / 1.4522 <br />0.9230 / 0.9229 <br />1.9762 / 1.9702 <br />4.3268 ! 43270 <br />Test End Time: <br />11:25 / 11:45 <br />11:25 / 11:45 <br />12:51 1 11:10 <br />4:06 14:23 <br />Final Readin (RF): <br />1.4521 / 1.4514 <br />0.9230 / 0.9228 <br />1.9761 / 1.9750 <br />4.3270 f 4.3270 <br />Test Duration: <br />15 min. / 15 min. <br />15 min. / 15 min. <br />15 min. 115 min. <br />15 min. 115 min. <br />Change in Reading (RF-R,): <br />.0006 /.0018 <br />.0000 /.0001 <br />.0001 /.0012 <br />.0002 /.0000 <br />Pass/Fail Threshold or Criteria: <br />.002 <br />.002 <br />.002 <br />.002 <br />Test Result: <br />X Pass ❑ Fail <br />X Pass ❑ Fail <br />X Pass ❑Fail <br />X Pass ❑ Fail <br />Is there a sensor in the sump? <br />X Yes ❑ No <br />X Yes ❑ No <br />X Yes ❑ No <br />X Yes C7 No <br />Does the sensor alarm when <br />either product or water is <br />X Yes ❑ No ❑ NA <br />X Yes ❑ No ❑ NA <br />X Yes ❑ No DNA <br />X Yes ❑ No ❑ NA <br />detected? <br />Was sensor removed for testing? <br />X Yes ❑ No ❑ NA <br />X Yes ❑ No ❑ NA <br />X Yes ❑ No [INA <br />X Yes ❑ No ❑ NA <br />Was sensor properly replaced and <br />X Yes ❑ No ❑ NA <br />X Yes ❑ No ❑ NA <br />X Yes ❑ No ❑ NA <br />X Yes ❑ No ❑ NA <br />verified functional after testing? <br />Comments (include information on repairs made prior to testing and recommended follow-up for failed tests) <br />
The URL can be used to link to this page
Your browser does not support the video tag.