Laserfiche WebLink
0 <br />0 <br />Page of <br />SWRCB, January 2002 <br />15, <br />FELL RISER CONTAINMENT SUMP TESTING <br />Facility is Not Equipped With Fill Riser Containment Sumps <br />LJ <br />Fill Riser Containment Sumps are Present, but were Not Tested ❑ <br />Test Method Developed By: <br />❑ Sump Manufacturer <br />❑ Industry Standard ❑ Professional Engineer <br />x Other (Spec) County Protocol <br />Test Method Used: <br />❑ Pressure <br />❑ Vacuum <br />X Hydrostatic <br />D Other (Spec) <br />Test Equipment Used: Incon STS <br />Equipment Resolution: .002 <br />Fill Sump #T-I <br />Fill Sump #T-2 <br />Fill Sump 4T-3 <br />Fill Sump #T-4 <br />Sump DiameterEnk <br />42„ <br />42„ <br />42" <br />Sum Depth: <br />76.5" <br />76" <br />39" <br />Height from Taap ofNIA <br />NIA <br />NIA <br />Ili hest Pi in :Height <br />from Taowest10.5" <br />g65 <br />10.5" <br />9"Electrical <br />PeneCondition <br />of suGood <br />Good <br />Good <br />testing: <br />Portion of Sump Tested <br />2" over collar <br />2" over collar <br />2" over collar <br />2" over collar <br />Sump Material: <br />Fiberglass <br />Fiberglass <br />Fiberglass <br />Fiberglass <br />Wait time between applying <br />30 minutes <br />30 minutes <br />30 minutes <br />30 minutes <br />pressure/vacuum/water and <br />startin test:: <br />Test Start Time: <br />11:10 / 11:27 <br />11:10 / 11:27 <br />12:36 / 12:54 <br />3:51 / 4:08 <br />Initial Reading (R,): <br />1.4527 / 1.4522 <br />0.9230 / 0.9229 <br />1.9762 / 1.9702 <br />4.3268 ! 43270 <br />Test End Time: <br />11:25 / 11:45 <br />11:25 / 11:45 <br />12:51 1 11:10 <br />4:06 14:23 <br />Final Readin (RF): <br />1.4521 / 1.4514 <br />0.9230 / 0.9228 <br />1.9761 / 1.9750 <br />4.3270 f 4.3270 <br />Test Duration: <br />15 min. / 15 min. <br />15 min. / 15 min. <br />15 min. 115 min. <br />15 min. 115 min. <br />Change in Reading (RF-R,): <br />.0006 /.0018 <br />.0000 /.0001 <br />.0001 /.0012 <br />.0002 /.0000 <br />Pass/Fail Threshold or Criteria: <br />.002 <br />.002 <br />.002 <br />.002 <br />Test Result: <br />X Pass ❑ Fail <br />X Pass ❑ Fail <br />X Pass ❑Fail <br />X Pass ❑ Fail <br />Is there a sensor in the sump? <br />X Yes ❑ No <br />X Yes ❑ No <br />X Yes ❑ No <br />X Yes C7 No <br />Does the sensor alarm when <br />either product or water is <br />X Yes ❑ No ❑ NA <br />X Yes ❑ No ❑ NA <br />X Yes ❑ No DNA <br />X Yes ❑ No ❑ NA <br />detected? <br />Was sensor removed for testing? <br />X Yes ❑ No ❑ NA <br />X Yes ❑ No ❑ NA <br />X Yes ❑ No [INA <br />X Yes ❑ No ❑ NA <br />Was sensor properly replaced and <br />X Yes ❑ No ❑ NA <br />X Yes ❑ No ❑ NA <br />X Yes ❑ No ❑ NA <br />X Yes ❑ No ❑ NA <br />verified functional after testing? <br />Comments (include information on repairs made prior to testing and recommended follow-up for failed tests) <br />