My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2007 - 2010
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
D
>
DUCK CREEK
>
3633
>
2300 - Underground Storage Tank Program
>
PR0232461
>
COMPLIANCE INFO 2007 - 2010
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/6/2020 4:40:11 PM
Creation date
11/4/2018 3:46:29 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2007 - 2010
RECORD_ID
PR0232461
PE
2361
FACILITY_ID
FA0003758
FACILITY_NAME
RYDER TRUCK RENTAL #1071
STREET_NUMBER
3633
STREET_NAME
DUCK CREEK
STREET_TYPE
DR
City
STOCKTON
Zip
95215
APN
17331001
CURRENT_STATUS
01
SITE_LOCATION
3633 DUCK CREEK DR
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\D\DUCK CREEK\3633\PR0232461\COMPLIANCE INFO 2007 - 2010.PDF
QuestysFileName
COMPLIANCE INFO 2007 - 2010
QuestysRecordDate
4/25/2018 11:45:33 PM
QuestysRecordID
3869854
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
277
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Date: December 17, 2007 <br />Revised by: Randy Golding <br />Approved by: Randy Golding <br />Praxair Services, Inc. QA <br />Tracer Tighlg <br />Version 6 <br />has displaced the entire volume of the vent piping. The concentration of the tracer in the receiving container is then <br />measured. <br />Leak Simulation <br />Injecting a tracer into the backfill performs a leak simulation. The leak simulation tracer is not one of the tracers used in <br />testing the system. The migration period of the leak simulation tracer is monitored through the sampling probes. The <br />minimum migration time required for the test is equal to the time required for the leak simulation tracer to move an <br />acceptable distance. The minimal acceptable distance is the longest distance that the test tracer would have to travel from <br />any leak location to the location of a sampling probe. <br />Sample Collection <br />Once the leak simulation migration period is determined, the inoculation and waiting period is completed and sampling <br />can begin. Vapor samples are collected from all sampling probes. Additional vapor samples may be collected from sumps <br />containing UST components, under dispenser containers (UDCs) and from the interstitial spaces of double walled <br />components. <br />Sample Analysis <br />Samples are analyzed using an on site laboratory grade gas chromatograph (GC). The GC is calibrated using an external <br />gas standard. Samples are analyzed by direct injection into the GC. The results are evaluated by comparison to the <br />analytical standard. Whenever tracer is detected in the subsurface samples, blanks are run to validate the tracer detection. <br />Spill -Bucket Testing <br />Over -spill -buckets are tested hydro -statically. A decrease in water level indicates a leak. If leaks occur, spill bucket seals <br />should be repaired or replaced. <br />Reporting <br />The findings of the Tracer Tight* ELD test and site evaluation will be summarized in a written report and sent to the client <br />within two weeks of the completion of the fieldwork. All data acquired from probe and sump samples will be reported <br />along with spill bucket hydro -test results. <br />THIS INFORMATION IS THE PROPERTY OF PRAXAIR SERVICES, INC.. <br />3 of 3 <br />
The URL can be used to link to this page