COMPLIANCE INFO 2007 - 2010
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
D
>
DUCK CREEK
>
3633
>
2300 - Underground Storage Tank Program
>
PR0232461
>
COMPLIANCE INFO 2007 - 2010
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/6/2020 4:40:11 PM
Creation date
11/4/2018 3:46:29 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2007 - 2010
RECORD_ID
PR0232461
PE
2361
FACILITY_ID
FA0003758
FACILITY_NAME
RYDER TRUCK RENTAL #1071
STREET_NUMBER
3633
STREET_NAME
DUCK CREEK
STREET_TYPE
DR
City
STOCKTON
Zip
95215
APN
17331001
CURRENT_STATUS
01
SITE_LOCATION
3633 DUCK CREEK DR
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\D\DUCK CREEK\3633\PR0232461\COMPLIANCE INFO 2007 - 2010.PDF
QuestysFileName
COMPLIANCE INFO 2007 - 2010
QuestysRecordDate
4/25/2018 11:45:33 PM
QuestysRecordID
3869854
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
277
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SW RCB', January 2002 <br />S. FILL RISER CONTAINMENT SUMP TESTING <br />Page 7 <br />Facility is Not Equipped With Fill Riser Containment Sumps <br />Fill Riser Containment Sumps are Present, but were Not Tested <br />Test Method Developed By: F-1 Sump Manufacturer F-1 Industry Standard X1 Professional Engineer <br />Other (Specify) <br />Test Method Used: ❑ Pressure F Vacuum ❑X Hydrostatic <br />F-] Other (Specify) <br />Test Equipment Used: vplt <br />Diameter: <br />Height from Tank Top to Top of <br />Highest Piping Pentration: <br />Height from Tank Top to <br />Lowest Electrical Pentration: <br />Condition of Sump prior to <br />testing: <br />Portion of Sump Tested: <br />Sump Material: <br />Wait time between applying <br />pressure/vacuum/water and starting <br />test: <br />Test Start Time: <br />Initial Reading (R1 ): <br />Test End Time: <br />Final Reading (RF ): <br />Test Duration: <br />Change in Reading (RF - Rt ): <br />Pass/Fail Threshold or Criteria: <br />Test Result 't� <br />Is there a sensor in the sump? <br />Does the sensor alarm when <br />either product or water is <br />detected? <br />Was sensor removed for testing? <br />Was sensor properly replaced and <br />verified functional after testing? <br />Fill Sump # 4 USE I Fill Sump # <br />ID <br />8:55 <br />11.674 <br />9:06 <br />2.584 <br />11min <br />.7gph <br />05gph <br />Pass E Fail ElPass E <br />Yes No E Yes C <br />Yes DNo[:]NA Yes QN <br />Yes❑NOE:]NA Oyes[:]N <br />Yes0NcE]NA E:]Yes[—]N <br />Equipment Resolution: vplt to gph <br />Fill Sump # I Fill Sump # <br />Fail o Pasts Fail 0 Pass D Fail <br />No Yes No Yes No <br />::INA EYesE:]NCNA[]Yes❑No[-]N <br />�:]NA DYes N 47]NA [:] Yes No <br />::INA OYes [:]NCNA [:] Yes [:] No[]N <br />Comments - (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />The second set of used oil data is for trouble shooting pourposes, only. - <br />